Contamination of Healthcare Worker Personal Protective Equipment with MRSA Outside the Intensive Care Unit Setting
Published online by Cambridge University Press: 02 November 2020
Abstract
Background: Estimates of contamination of healthcare personnel (HCP) gloves and gowns with methicillin-resistant Staphylococcus aureus (MRSA) following interactions with colonized or infected patients range from 17% to 20%. Most studies were conducted in the intensive care unit (ICU) setting where patients had a recent positive clinical culture. The aim of this study was to determine the rate of MRSA transmission to HCP gloves and gown in non-ICU acute-care hospital units and to identify associated risk factors. Methods: Patients on contact precautions with history of MRSA colonization or infection admitted to non-ICU settings were randomly selected from electronic health records. We observed patient care activities and cultured the gloves and gowns of 10 HCP interactions per patient prior to doffing. Cultures from patients’ anterior nares, chest, antecubital fossa and perianal area were collected to quantify bacterial bioburden. Bacterial counts were log transformed. Results: We observed 55 patients (Fig. 1), and 517 HCP–patient interactions. Of the HCP–patient interactions, 16 (3.1%) led to MRSA contamination of HCP gloves, 18 (3.5%) led to contamination of HCP gown, and 28 (5.4%) led to contamination of either gloves or gown. In addition, 5 (12.8%) patients had a positive clinical or surveillance culture for MRSA in the prior 7 days. Nurses, physicians and technicians were grouped in “direct patient care”, and rest of the HCPs were included in “no direct care group.” Of 404 interactions, 26 (6.4%) of providers in the “direct patient care” group showed transmission of MRSA to gloves or gown in comparison to 2 of 113 (1.8%) interactions involving providers in the “no direct patient care” group (P = .05) (Fig. 2). The median MRSA bioburden was 0 log 10CFU/mL in the nares (range, 0–3.6), perianal region (range, 0–3.5), the arm skin (range, 0-0.3), and the chest skin (range, 0–6.2). Detectable bioburden on patients was negatively correlated with the time since placed on contact precautions (rs= −0.06; P < .001). Of 97 observations with detectable bacterial bioburden at any site, 9 (9.3%) resulted in transmission of MRSA to HCP in comparison to 11 (3.6%) of 310 observations with no detectable bioburden at all sites (P = .03). Conclusions: Transmission of MRSA to gloves or gowns of HCP caring for patients on contact precautions for MRSA in non-ICU settings was lower than in the ICU setting. More evidence is needed to help guide the optimal use of contact precautions for the right patient, in the right setting, for the right type of encounter.
Funding: None
Disclosures: None
- Type
- Oral Presentations
- Information
- Copyright
- © 2020 by The Society for Healthcare Epidemiology of America. All rights reserved.