Hostname: page-component-78c5997874-j824f Total loading time: 0 Render date: 2024-11-04T19:27:24.582Z Has data issue: false hasContentIssue false

Biological Indicators for a Liquid Chemical Sterilizer A Solution to the Instrument Reprocessing Problem?

Published online by Cambridge University Press:  21 June 2016

Walter W. Bond*
Affiliation:
Hospital Infections Program, National Center for Infectious Diseases, Centers For Disease Control and Prevention, Atlanta, Georgia
*
Hospital Environment Laboratory Branch, Hospital Infections Program, National Center for Infectious Diseases, Centers for Disease Control and Prevention, Mailstop C-01, Atlanta, GA 30333
Rights & Permissions [Opens in a new window]

Abstract

Image of the first page of this content. For PDF version, please use the ‘Save PDF’ preceeding this image.'
Type
Editorial
Copyright
Copyright © The Society for Healthcare Epidemiology of America 1993

References

1. Kralovic, RC. Use of biological indicators designed for steam or ethylene oxide to monitor a liquid chemical sterilization process. Infect Control Hasp Epidemiol 1993;14:313–319.Google ScholarPubMed
2. Crow, S. Peracetic acid sterilization: a timely development for a busy healthcare industry. Infect Control Hasp Epidemiol 1992;13:111–113.Google ScholarPubMed
3. Gurevich, I, Qadri, SMH, Cunha, BA. False positive results of spore tests from improper clip use with Steris chemical sterilant system. Am /Infect Control 1993;21:42–43. Letter.Google ScholarPubMed
4. Block, SS, ed. Disinfection, Sterilization, and Preservation. 4th ed. Philadelphia, PA: Lea & Febiger; 1991.Google Scholar
5. Morrissey, RF; Phillips, GB, eds. Sterilization Technology: A Practical Guide for Manufacturers and Users of Health Care Products. New York, NY: Van Nostrand and Reinhold; 1993.Google Scholar
6. Vesley, D, Norlien, KG, Nelson, B, Ott, B, Streifel, PJ. Significant factors in the disinfection and sterilization of flexible endoscopes. Am J Infect Control 1992;20:291–300.CrossRefGoogle ScholarPubMed
7. Pappas, SA, Schaff, DM, Di Costanzo, MB, King, FW, Sharp, JT Contamination of flexible fiberoptic bronchoscopes. Am Rev Respir Dis 1983;127:391–392. Letter.Google ScholarPubMed
8. Steris Corporation. STERIS SYSTEM 1: Technical Data Monograph M001.080588. Painesville, OH: STERIS Corp.; 1988.Google Scholar
9. Kralovic, RC, Badertscher, DC. Bactericidal and sporicidal efficacy of a pet-acetic acid-based liquid chemical sterilant. Abstracts of the Annual Meeting for the American Society of Microbiologists. Miami Beach, FL, May 8-13, 1988:Q114.Google Scholar
10. STERIS Corp. STERNS SYSTEM I Technical Brief Biological Monitoring. Painesville, OH: STERIS Corp.; 1988.Google Scholar
11. Ott, BJ, Nelson, B. Understanding the structure and function of endoscope channels: the inside story. Society of Gastrointestinal Assistants Journal 1987;9:184–187.Google Scholar
12. Bond, WW, Ott, BJ, Franke, KA, McCracken, JE. Effective use of liquid chemical germicides on medical devices: instrument design problems. In: Block, SS, ed. Disinfection, Sterilization, and A-eservation. 4th ed. Philadelphia, PA: Lea & Febiger 1991,1097–1106.Google Scholar
13. Yabe, H, Sasa, H, Nakajima, Y, et al. Method of Cleaning Endoscope Channels. United States patent Number 4,576,650. Washington, DC: U.S. Patent and Trademark Office; March 18 1986.Google Scholar
14. Centers for Disease Control and Prevention. Guidelines for Handwashing and Hospital Environmental Control. Atlanta, GA CDC-HHS publication no. 99.1117;1985.Google Scholar
15. Rutala, WA, Clontz, EP, Weber, DJ, Hoffmann, KK. Disinfection practices for endoscopes and other semicritical items. Infect Control Hosp Epidemiol 1991;12:282–288.CrossRefGoogle ScholarPubMed
16. Spach, DH, Silverstein, FE, Stamm, WE. Transmission of infection by gastrointestinal endoscopy. Ann Intern Med 1993;118:117–128.CrossRefGoogle ScholarPubMed
17. Duppler, DW. Iaparoscopic instrumentation, videoimaging, and equipment disinfection and sterilization. Surg Clin North Am 1992;72:1021–1032.CrossRefGoogle Scholar
18. Center for Healthcare Environmental Management. Processing flexible endoscopes: glutaraldehyde and the STERIS SYSTEM 1. Healthcave Hazardous Materials Management 1992;5:7–10 Google Scholar