Hostname: page-component-cd9895bd7-gbm5v Total loading time: 0 Render date: 2024-12-23T09:42:21.018Z Has data issue: false hasContentIssue false

Risk of Human Immunodeficiency Virus and Hepatitis C Virus Infection Related to Endocavitary Ultrasound Probe Exposure in France

Published online by Cambridge University Press:  10 May 2016

Thomas Bénet
Affiliation:
Infection Control and Epidemiology Unit, Edouard Herriot Hospital, Hospices Civils de Lyon, Lyon, France; and Epidemiology and Public Health Unit, University of Lyon 1, Lyon, France
Jacques Ritter
Affiliation:
Virology Laboratory, Croix-Rousse Hospital, Hospices Civils de Lyon, Lyon, France
Philippe Vanhems*
Affiliation:
Infection Control and Epidemiology Unit, Edouard Herriot Hospital, Hospices Civils de Lyon, Lyon, France; and Epidemiology and Public Health Unit, University of Lyon 1, Lyon, France
*
Service d’Hygiène, Epidémiologie et Prévention, Hôpital Edouard Herriot, Hospices Civils de Lyon, 5 place d’Arsonval, 69437 Lyon, Cedex 03, France ([email protected]).

Abstract

Image of the first page of this content. For PDF version, please use the ‘Save PDF’ preceeding this image.'
Type
Research Brief
Copyright
© 2014 by The Society for Healthcare Epidemiology of America. All rights reserved.

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Tablan, OC, Anderson, LJ, Besser, R, et al. Guidelines for preventing health-care–associated pneumonia, 2003: recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee. MMWR Recomm Rep 2004;53:136.Google Scholar
2. Rutala, WA, Weber, DJ; Healthcare Infection Control Practices Advisory Committee. Guideline for disinfection and sterilization in healthcare facilities, 2008. Atlanta: Centers for Disease Control and Prevention, 2008. http://www.cdc.gov/hicpac/Disinfection_Sterilization/acknowledg.html. Accessed February 26, 2014.Google Scholar
3. Haut Conseil de la Santé Publique. Gaines de protection à usage unique pour dispositifs médicaux réutilisables: recommandations d’utilisation. Haut Conseil de la Santé Publique, 2007. http://www.hcsp.fr/docspdf/avisrapports/hcspr20071214_GainesProtec.pdf. Accessed February 26, 2014.Google Scholar
4. Kac, G, Podglajen, I, Si-Mohamed, A, Rodi, A, Grataloup, C, Meyer, G. Evaluation of ultraviolet C for disinfection of endocavitary ultrasound transducers persistently contaminated despite probe covers. Infect Control Hosp Epidemiol 2010;31(2):165170.Google Scholar
5. Casalegno, J, Le Bail Carval, K, Eibach, D, et al. High risk HPV contamination of endocavity vaginal ultrasound probes: an underestimated route of nosocomial infection? PLoS One 2012;7(10):e48137.Google Scholar
6. Ferhi, K, Rouprêt, M, Mozer, P, Ploussard, G, Haertig, A, de La Taille, A. Hepatitis C transmission after prostate biopsy. Case Rep Urol 2013;2013:797248. doi:10.1155/2013/797248.Google Scholar
7. Trombert-Paviot, B, Rector, A, Baud, R, et al. The development of CCAM: the new French coding system of clinical procedures. HIM J 2003;31:111.Google Scholar
8. Ma, ST, Yeung, AC, Chan, PK, Graham, CA. Transvaginal ultrasound probe contamination by the human papillomavirus in the emergency department. Emerg Med J 2013;30(6):472475.Google Scholar
9. Amis, S, Ruddy, M, Kibbler, CC, Economides, DL, MacLean, AB. Assessment of condoms as probe covers for transvaginal sonography. J Clin Ultrasound 2000;28(6):295298.3.0.CO;2-G>CrossRefGoogle ScholarPubMed
10. Lessa, F, Tak, S, Devader, SR, et al. Risk of infections associated with improperly reprocessed transrectal ultrasound-guided prostate biopsy equipment. Infect Control Hosp Epidemiol 2008;29(4):289293.Google Scholar