Article contents
Pseudomonas aeruginosa Infections Associated with Use of Povidone-Iodine in Patients Receiving Continuous Ambulatory Peritoneal Dialysis
Published online by Cambridge University Press: 21 June 2016
Abstract
Fifteen episodes of infection due to Pseudomonas aeruginosa, including peritonitis and catheter site infections, occurred in nine patients receiving continuous ambulatory peritoneal dialysis over a 27-month period. Eight episodes were associated with catheter loss. Occurrence of P aeruginosa infection was significantly associated with use of povidone-iodine solution to cleanse the catheter site. There was no association with use of povidone-iodine solution to disinfect tubing connections, use of other skin care products or exposure to other environmental sources of P aeruginosa. Cultures of available povidone-iodine products were negative. Local irritation and alteration in skin flora caused by antiseptic solution or low-level contamination of povidone-iodine solution are potential mechanisms of infection.
- Type
- Original Articles
- Information
- Copyright
- Copyright © The Society for Healthcare Epidemiology of America 1989
References
- 8
- Cited by