Impact Statement
The paper addresses an ongoing discussion in the field of combustion diagnostics, and in the field of soot formation in particular. Since approximately 20 years ago, it has been common to use macroscopic dilution tubes for the sampling of flame gas and particulates. However, the correct functioning of the sampling procedure has not been proved so far. Here, computational fluid dynamics (Reynolds-averaged Navier–Stokes and large-eddy simulations) is used to investigate the important claims of the procedure: rapid mixing and quenching of the flame gas sample. As result, a large potential for optimization of the experimental procedure is identified. It is the first model study which considers the gas flow in the interior of the dilution tubes.
1. Introduction
Fuel rich hydrocarbon flames can give rise to soot formation, a highly complex process which involves homogeneous gas phase reactions, a gas-particle transition, heterogeneous surface growth and aerosol dynamics at high temperatures. The amount of soot which is actually formed depends on a variety of parameters such as type of fuel, fuel-to-air ratio, temperature and pressure. In the early stages of soot formation, particle number densities can exceed 1012 cm−3 and particle sizes are just a few nanometres. Accurate measurements are still a challenge under such conditions. Much of the early data on soot formation were obtained from non-intrusive optical measurements of the particulate phase and from molecular beam sampling and mass spectroscopy of gas phase components. As prominent result, it was found that soot particle inception contributes only a little (roughly 10 %–20 %) to the total soot volume or mass being formed and most of the soot is formed by heterogeneous surface growth, as reviewed earlier (Reference Haynes and WagnerHaynes & Wagner, 1981; Reference WagnerWagner, 1979). Polycyclic aromatics were expected to be precursors of the first, nascent soot particles and finally, pyrene was identified as key intermediate in soot formation and used in the so-called HACA mechanism (hydrogen abstraction, C2H2 addition) to model soot formation numerically (Reference Appel, Bockhorn and FrenklachAppel, Bockhorn, & Frenklach, 2000). The recent research focuses on the feasibility to include further polyaromatic hydrocarbons in the processes of particle inception and surface growth and on the explanation, how spherical structures can emerge from the interaction of planar precursors (Reference Frenklach and MebelFrenklach & Mebel, 2020; Reference Johansson, Head-Gordon, Schrader, Wilson and MichelsenJohansson, Head-Gordon, Schrader, Wilson, & Michelsen, 2018; Reference WangWang, 2011).
The use of horizontal dilution tubes and scanning mobility particle sizers (SMPS) for soot particle characterization was first proposed by Reference Kasper, Siegmann and SattlerKasper, Siegmann, & Sattler (1997). Later, Reference Zhao, Yang, Johnston, Wang, Wexler, Balthasar and KraftZhao, Yang, Johnston, et al. (2003) and Reference Zhao, Yang, Wang, Johnston and WangZhao, Yang, Wang, et al. (2003) extended the earlier work emphasizing the need for high dilution ratios (DR), because the upper limit of particle number concentrations is of the order 106–107 cm−3 in SMPS. In addition, reliable particle sampling from a high-temperature reacting environment, like postflame gases, requires fast quenching in order to suppress particle inception, surface growth and coagulation in the measurement device. A turbulent mixing process was expected to meet these requirements. Hence, it was proposed to introduce a sampling tube of approximately 10 mm diameter into the flame, feed it with a turbulent cold inert dilution gas flow and sample the hot flame gas through a small (0.1–0.5 mm inner diameter) orifice under laminar flow conditions. As an alternative to free-standing sampling tubes, these may also be embedded in cooled stagnation plates (Reference Camacho, Liu, Gu, Lin, Huang, Tang and WangCamacho et al., 2015). The flow arrangement corresponds to a jet in cross-flow configuration. At constant dilution gas flow, the DR is a function of the orifice diameter and the pressure drop at the orifice: DR is high for small orifice diameters and for small pressure drops. Experimentally, it was found that the measured particle size distribution changes with increasing DR and finally becomes independent of DR above some critical value which is of the order of 104 (Reference Zhao, Yang, Johnston, Wang, Wexler, Balthasar and KraftZhao, Yang, Johnston, et al., 2003; Reference Zhao, Yang, Wang, Johnston and WangZhao, Yang, Wang, et al., 2003). In a more recent study, the optimum DR was found to be much lower, in the range 250–1000 (Reference Camacho, Liu, Gu, Lin, Huang, Tang and WangCamacho et al., 2015; Reference Tang, Mei and YouTang, Mei, & You, 2016). Meanwhile, horizontal dilution tubes have also been used in the analysis of gas phase soot precursors (Reference Adamson, Skeen, Ahmed and HansenAdamson, Skeen, Ahmed, & Hansen, 2018).
Since the presence of a large sampling nozzle or a stagnation plate causes distortions of the flow and temperature fields in the flame, error analyses were performed by several authors both in molecular beam sampling and in conventional sampling studies to quantify these effects (Reference Camacho, Liu, Gu, Lin, Huang, Tang and WangCamacho et al., 2015; Reference Egolfopoulos, Hansen, Ju, Kohse-Höinghaus, Law and QiEgolfopoulos et al., 2014; Reference Gururajan, Egolfopoulos and Kohse-HöinghausGururajan, Egolfopoulos, & Kohse-Höinghaus, 2015; Reference Hansen, Cool, Westmoreland and Kohse-HöinghausHansen, Cool, Westmoreland, & Kohse-Höinghaus, 2009; Reference Saggese, Cuoci, Frassoldati, Ferrario, Camacho, Wang and FaravelliSaggese et al., 2016; Reference Skovorodko, Tereshchenko, Korobeinichev, Knyazkov and ShmakovSkovorodko, Tereshchenko, Korobeinichev, Knyazkov, & Shmakov, 2013; Reference Struckmeier, Oßwald, Kasper, Böhling, Heuser, Köhler and Kohse-HöinghausStruckmeier, Oßwald, Kasper, et al., 2009; Reference Tang, Mei and YouTang et al., 2016). Based on studies of the gas flow around the probe, there seems to be consensus that a horizontal dilution tube can map the flame conditions a few millimetres upstream of the sampling position correctly and no other serious errors need to be considered. Subsequent to the work by Reference Zhao, Yang, Johnston, Wang, Wexler, Balthasar and KraftZhao, Yang, Johnston, et al. (2003) and Reference Zhao, Yang, Wang, Johnston and WangZhao, Yang, Wang, et al. (2003) the described experimental set-up has been used in numerous subsequent studies, only a relevant selection of which is mentioned here (Reference Abid, Heinz, Tolmachoff, Phares, Campbell and WangAbid et al., 2008; Reference Camacho, Liu, Gu, Lin, Huang, Tang and WangCamacho et al., 2015; Reference Commodo, Sgro, Minutolo and D'AnnaCommodo et al., 2013, Reference Commodo, De Falco, Bruno, Borriello, Minutolo and D'Anna2015; Reference Ghiassi, Jaramillo, Toth and LightyGhiassi, Jaramillo, Toth, & Lighty, 2016; Reference Sgro, Barone, Commodo, D'Alessio, De Filippo, Lanzuolo and MinutoloSgro et al., 2009; Reference Tang, Mei and YouTang et al., 2016). All of these studies confirmed that fuel-rich flames of aliphatic hydrocarbons, ethylene in particular, have a great potential to develop bimodal soot particle size distributions.
As described above, previous studies have considered flow conditions and errors which may occur in the flame environment around the sampling tube. The present study is motivated by the lack of knowledge concerning the flow conditions inside the sampling tube which determine the mixing efficiency of the hot flame gas sample into the cold dilution gas flow as well as the time scales at which mixing and quenching occur. A preliminary computational fluid dynamics (CFD) analysis showed that the mixing process is poor and is not complete when the gas enters the differential mobility analyzer (DMA) for particle size analysis (Reference Mätzing and StapfMätzing & Stapf, 2019). The previous study is now extended to clarify the flow conditions in free-standing and in embedded horizontal dilution tubes using both Reynolds-averaged Navier–Stokes (RANS) and large-eddy simulations (LES) on grids with high spatial resolution. In addition, a revised procedure is proposed to determine the orifice flow rate and the DR.
2. Theory
The sampled gas flow is roughly 3–4 orders of magnitudes smaller than the dilution flow. Since it is not practical to measure it directly, the orifice flow is calibrated with ambient air and extrapolated to flame conditions. For the extrapolation, it is usually assumed that the orifice flow is a laminar Poiseuille flow with a flow rate proportional to the pressure drop and inversely proportional to the gas viscosity (Reference Camacho, Liu, Gu, Lin, Huang, Tang and WangCamacho et al., 2015; Reference Tang, Mei and YouTang et al., 2016; Reference Zhao, Yang, Wang, Johnston and WangZhao, Yang, Wang, et al., 2003). However, Poiseuille flow requires long pipes to develop fully with pipe length much larger than pipe diameter (Reference LaffertyLafferty, 1998). In typical horizontal soot sampling tubes, the orifice length is given by the tube wall thickness, roughly around 0.5 mm, and hence less than five times the orifice diameter. Therefore, the orifice flow might be described better by a different approach. In this paper, the orifice flow is described by Bernoulli's equation and the dilution process is described by a jet in cross-flow concept.
2.1 Orifice flow revisited
For incompressible fluid flow (at Mach number <0.3), the orifice flow Qorf is commonly described in terms of the isentropic flow rate derived from Bernoulli's equation,
where ρ is the fluid density, Aorf is the orifice cross-section and Cd is the discharge coefficient, which is around 0.7 typically (Reference Borutzky, Barnard and ThomaBorutzky, Barnard, & Thoma, 2002; Reference LaffertyLafferty, 1998; Reference Oertel, Prandtl and BöhleOertel, Prandtl, & Böhle, 2008), but may exceed 1 due to the presence of a cross-flow (Reference Berger, Gourdain, Bauerheim and DevillezBerger, Gourdain, Bauerheim, & Devillez, 2019). Isentropic flow occurs under adiabatic conditions and, for pressure drops ΔPorf < 200 Pa, the adiabatic cooling is expected to be less than 5 K (for diatomic gas) in horizontal flame gas sampling tubes under atmospheric conditions. Accordingly, ρ changes by less than 0.2 % and can be regarded as constant. Equation (1) predicts the orifice flow to be proportional to the square root of the pressure drop and to be independent of the gas viscosity. However, despite the vast number of publications about orifice flow, to the authors’ knowledge a high-temperature validation (T > 700 K) of (1) is not available in the literature.
2.2 The jet in cross-flow approach
From the fluid mechanics point of view, the flame gas sampling by horizontal dilution tubes represents a jet in cross-flow arrangement, wherein the gas sample flow is the laminar jet and the cold dilution gas flow is the transverse flow. Due to their wide range of practical applications, jets in cross-flow have been investigated intensively for many years (Reference Chang, Shao, Hu and ZhangChang, Shao, Hu, & Zhang, 2016; Reference MaheshMahesh, 2013; Reference Muppidi and MaheshMuppidi & Mahesh, 2005). The flow characteristics are described by several characteristic numbers:
• the jet to cross-flow velocity ratio $R = {({\rho _j}/{\rho _\infty })^{0.5}} \times {u_j}/{u_\infty }$;
• the jet to cross-flow density ratio $S = {\rho _j}/{\rho _\infty }$;
• the jet to cross-flow momentum flux ratio J = R 2;
• the jet Reynolds number $R{e_j} = {u_j}{D_j}/{\mu _j},{\mu _j} = {\eta _j}/{\rho _j}$;
where u is velocity, ρ is density, η is dynamic viscosity, μ is kinematic viscosity, D is diameter and the subscripts are j for the jet and ∞ for the cross-flow. Different from flame gas sampling, experimental investigations usually employ long jet pipes to ensure fully developed flow. High R, J and Rej were found to favour the mixing of the jet into the cross-flow, but even in case of laminar jets (low Rej and R), turbulent vortex structures can develop which induce a high mixing efficiency. Yet, extremely small jet-to-cross-flow momentum flux ratios, J < 5, may prevent the jet from penetrating deeply into the cross-flow and may cause the jet to adhere to the wall or wall boundary layer (Reference KaragozianKaragozian, 2014; Reference MaheshMahesh, 2013). As shown earlier (Reference Mätzing and StapfMätzing & Stapf, 2019), such a situation may arise under flame gas sampling conditions, when a high-temperature and high-viscosity jet enters into a much colder cross-flow with R = 0.14–0.77 and J = 0.02–0.6 (these values hold in the present study, too).
3. Computational methods
3.1 CFD simulations
The simulations were performed for free-standing and embedded dilution tubes, as outlined in figure 1(a,b). The free-standing dilution tube served as a base case. The experimental set-up was used in our laboratory previously (Reference Frenzel, Krause and TrimisFrenzel, Krause, & Trimis, 2017) and it is very similar to other common set-ups (Reference Zhao, Yang, Johnston, Wang, Wexler, Balthasar and KraftZhao, Yang, Johnston, et al., 2003). The uncooled, free-standing ceramic (Al2O3) dilution tube was 9 mm inner diameter, with a wall thickness of 0.5 mm; the pinhole diameter was Dorf = 0.3 mm. The input nitrogen dilution flow was 30 s.l.p.m. $(1\ {\rm s.l.p.m.} = 1.66 \times 10^{-5}\ {\rm Nm}^{3}\ {\rm sec}^{-1})$, which corresponds to a Reynolds number Re = 5000. At the measurement locations ΔP1 and ΔP2 in figure 1(c), low differential pressure sensors were installed and the pressure was assumed to drop linearly along the tube axis. This assumption was confirmed during the simulations. Note that in this set-up, the outlets to the measurement device (DMA) and to the pump are in parallel, at slightly different vertical positions. Other set-ups may have different arrangements, e.g. outlets at equal vertical positions and also outlets which are oriented perpendicular to each other. Such a configuration was simulated earlier (Reference Mätzing and StapfMätzing & Stapf, 2019) with no difference in major findings about the flow properties. Hence, the current results are taken to be valid for most of the common geometric configurations and tube materials.
The solid tube wall is not modelled explicitly; therefore the orifice is represented by a small tube which is 0.5 mm long, i.e. the wall thickness. Occasional clogging of the orifice can pose experimental problems, as will be discussed below, but it is not the object of this study.
To simulate embedded dilution tubes, the same geometric configuration is used, but the wall temperature is set to a constant appropriate value, e.g. 400 K, which results from the intense cooling by the stagnation plate (Reference Saggese, Cuoci, Frassoldati, Ferrario, Camacho, Wang and FaravelliSaggese et al., 2016).
The simulations were performed for a single phase gas flow. Under sooting conditions, in particular, when the soot forming (inception) zone is studied, the soot volume fraction is typically below 10−7 and, the particle size is well below 100 nm, often below 10 nm. Thermophoretical effects can eventually accelerate the particle motion relative to the gas in the cooling region in front of the orifice (Reference Saggese, Cuoci, Frassoldati, Ferrario, Camacho, Wang and FaravelliSaggese et al., 2016). In and behind the orifice, the nanoparticle trajectories can be expected to follow the gas flow and, particle–flow interactions are negligible due to the very small volume fraction (Reference Corson, Mulholland and ZachariahCorson, Mulholland, & Zachariah, 2018; Reference FriedlanderFriedlander, 2000). Hence, as first approximation, two-phase flow modelling is not really mandatory to capture the important flow properties and processes in the dilution tube.
The CFD simulation was performed in three dimensions using Ansys Fluent. Two grids of different cell number and cell geometry were generated:
(i) an unstructured grid with 18.5 × 106 tetrahedral cells, using Fluent 17.2 for RANS and LES;
(ii) an unstructured grid with 3.2 × 106 polyhedral cells, using Fluent 14.5 for RANS only.
The calculations were started with a precursor RANS calculation on grid (ii), in order to estimate the integral length scale ${l_0} = {k^{0.5}}/({C_\mu }\ \omega )$, wherein k is the turbulent kinetic energy, ω is the specific dissipation rate and Cμ = 0.09 (Reference GerasimovGerasimov, 2016). Since approximately 5–10 cells across l 0 (∼270 μm) are required to resolve ∼80 % of the turbulent energy spectrum, grid (i) was generated for the LES calculations with roughly six times smaller cell volume. The two grids were also used for a study of grid independence.
The general form of the conservation equations, which are solved in CFD calculations, is
wherein t (s) is time, P (Pa) is pressure, τ (Pa) is stress tensor, E (J) is energy, λG (W (m K)−1) is heat conductivity of the gas, T (K) is temperature, yi (−) is the mass fraction of species i, Ji (kg (m2 s)−1) is the diffusion flux of species i and Ri (kg (m3 s)−1) is a source term of species i. The source term for the mass, Sm, is zero if no condensation or evaporation processes are considered. Similarly, Ri may be zero in the absence of chemical reactions. Here Fb is the source term for momentum which can be chosen to include gravity. The source term for energy, SE, includes heat transfer processes as well as reaction heats and heat exchange due to phase transitions, if applicable.
In the RANS calculations, the turbulence model SST k–ω was used with corrections for curvature and low Reynolds numbers Re. Near wall treatment was done by high resolution inflation layers. The spatial resolution at the walls was better than 170 μm in mesh (ii) and better than 30 μm in mesh (i). The dimensionless wall distance y + was always less than unity in the laminar sublayer for both meshes which means that transport properties at the wall boundary layer were fully captured (Reference Zirwes, Häber, Zhang, Kosaka, Dreizler, Steinhausen and BockhornZirwes et al., 2021).
The pressure based solver was used to solve the equation system with the SIMPLE algorithm for pressure–velocity coupling which is acceptable for transient calculations, too, according to the Ansys Fluent User's Guide. Second-order upwind schemes were used for discretization. For good convergence, the calculations were often continued until residuals dropped below 10−7.
The LES calculations were performed using mesh (i) according to the ANSYS guidelines (Reference GerasimovGerasimov, 2016). The spatial resolution was better than one fifth of the turbulence length scale which allows us to resolve roughly 80 % of the turbulent kinetic energy. For subgrid-scale modelling, the dynamic Smagorinsky model was used with wall Prandtl number set to 0.85. The time step was set to 15 μs, i.e. the average travel time across a cell.
During post-processing, the Q criterion, the λ 2 criterion as well as pressure and velocity fluctuations were used to detect vortices. In brief, the Q criterion defines a vortex in a region where the square of vorticity is larger than the square of strain rate meaning that rotational deformation is larger than stretching deformation. The λ 2 criterion determines vortex regions from the eigenvalues of the symmetric and antisymmetric parts of the velocity tensor: if two of the eigenvalues are negative, a local pressure minimum exists which induces vortex formation. None of these methods is unique for vortex identification, as has been discussed and reviewed by several authors (Reference FröhlichFröhlich, 2006; Reference HolménHolmén, 2012; Reference Jiang, Machiraju and ThomsonJiang, Machiraju, & Thomson, 2005; Reference KolárKolár, 2011). For example the Q criterion may not distinguish between shear and rotation induced vortices, the λ 2 criterion may not resolve closely neighboured vortices and some authors recommend scalar fluctuation monitoring to avoid problems related to numerical noise. But, as will be shown later, the methods used here gave very similar results showing little vortex formation in the dilution tube except close to and in the outlet pipes.
The mass or mole fractions of CO2 were used to monitor and assess the mixing of the flame gas into the dilution gas.
3.2 Gas properties and flow rate evaluation
The calculations were performed for the following cold and hot conditions:
(i) ambient air conditions to simulate the experimental calibration procedure; air was taken to be dry and free of trace gases (mole fractions ${x_{{\textrm{O}_2}}} = 0.21$, ${x_{{\textrm{N}_2}}} = 0.79$);
(ii) flame conditions were simulated without the flame gas flowing around the dilution tube, just by defining the temperature to be 1000 K at the orifice (Reference Zhao, Yang, Wang, Johnston and WangZhao, Yang, Wang, et al., 2003) and using the tube wall temperature profile shown in figure 1, assuming a CH4/O2 oxy-fuel flame, equivalence ratio Φ = 2.4, C/O = 0.6, the flame gas concentrations were estimated from Reference Köhler, Oßwald, Xu, Kathrotia, Hasse and RiedelKöhler et al. (2016) and from Reference Stelzner, Weis, Habisreuther, Zarzalis and TrimisStelzner, Weis, Habisreuther, Zarzalis, & Trimis (2017). They are listed in table 1. The selected gas mixture has a relatively high viscosity η, $\eta _{flame,1000\;\textrm{K}} = 3.64 \times {10^{ - 5}}\;\textrm{kg}\;{\textrm{(m}\ \textrm{s})^{ - 1}} = 364\;\mathrm{\mu }\textrm{P}$, approximately 10 % higher than in usual fuel–air flames (see table 2). Its molar weight and density are half that of air.
The orifice volume flows Qorf (s.l.p.m.) were determined from the calculated mass flows (kg s−1) and densities ρ (kg m−3) in the following way:
where Qorf, Torf and Porf all refer to the inlet (‘flame side’) conditions at the orifice entrance. The DR was determined from the dilution gas flow Q N2, 273.15 K and Qorf according to (7), and also from the calculated mole fractions of CO2 at the orifice entrance and at the DMA outlet. Equation (7) reads
4. Results
4.1 General flow properties
In the entrance section of the dilution tube, the dilution gas flow was found to rapidly loose its initial turbulence properties. While entering the tube with an initial Reynolds number Re ≈ 5000 and an initial turbulence intensity of 5 %, the specific turbulent dissipation rate in the dilution tube is around ω ≈ 4000 Hz which translates to a relaxation time τω ≈ 250 μs and to a relaxation length scale lω ≈ 4 mm. This behaviour is observed under hot (flame) conditions preferentially, it is much less under cold (calibration) conditions (not shown in figure 2).
Hence, Re decreases rapidly along the tube axis due to a temperature effect and falls below 2000 at the location of the orifice, as shown in figure 2. Farther downstream, Re increases a little again, and thereafter it separates into a low Re part and a high Re part. The two partial flows leave the dilution tube via the measurement (DMA) outlet and via the pump outlet, respectively (figure 2).
Figure 3 shows a contour plot of the specific dissipation rate around the orifice until approximately 200 mm downstream. It varies only between 3500 and 4500 s−1 which indicates rather uniform flow conditions. Figure 4 shows the radial velocity profile at the location of the orifice. While under cold conditions, the radial profile is rather flat, indicating turbulence, it is neither flat nor parabolic under hot (flame) conditions, which indicates the gas flow to be in the laminar to turbulent transition regime.
The results in figures 2–4 were derived from LES and RANS calculations, as indicated in the figure captions. Since RANS calculations cannot resolve details of transitional and turbulent flows, their feasibility and validity need to be investigated. As example, figure 5(a,b) compare the contour lines of the major flow velocity ux in the vicinity of the orifice inlet as obtained from RANS and LES calculations. Both results are very similar, e.g. the area weighted average ux is 13.5 m s−1 in both cases. This confirms the feasibility of RANS calculations in the present model. Moreover, RANS results obtained from both meshes (i) and (ii) also agree quite well which confirms the grid independence of results for these high resolution meshes.
4.2 Detection of vortex structures
Vorticity is a measure of the local spin rate and hence a good indicator for the presence and intensity of vortices. In the vicinity of the orifice, the vorticity ranges from ${\omega _v} = 5 \times {10^2}\unicode{x2013}2 \times {10^4}\;{\textrm{s}^{ - 1}}$ and, if plotted on isosurfaces of the Q or λ 2 criteria, low vorticity values are found around the tube axis, while high vorticity values prevail close to the wall, as shown in figure 6.
The observable vortex structures are tiny and quite uniformly distributed which indicates rather homogeneous flow conditions. This changes significantly towards the outlet section, where the vorticity reaches values above 105 s−1 and large vortex structures are visible (figure 7). Large vortex structures develop in the pump outlet, but it is remarkable that large scale structures are also visible in the DMA outlet despite its low Re number. Obviously, the length of the outlet tube is too short to level out the turbulent motion which originates from the region where the flow splitting starts. This is illustrated further in figure 8 which compares the pathlines in the two outlets. While the trajectories are parallel in the pump outlet, they are twisted or meandering in the DMA outlet. Turbulent flow at low Reynolds numbers is a well known phenomenon as described and reviewed by Reference Tsukahara, Seki, Kawamura and TochioTsukahara, Seki, Kawamura, & Tochio (2005).
A more instructive result is obtained, when the isosurface is coloured by the mean mass fraction $\langle {y_{\textrm{C}{\textrm{O}_2}}}\rangle $ of CO2, as shown in figures 9 and 10. According to figure 8, a ring type puff is observed approx. 200 mm (≈10 ms) downstream of the orifice. Obviously, the sampled flame gas disperses quite well in the hot boundary layer at the wall, but it does not mix into the interior of the dilution gas flow due to the large viscosity difference, as mentioned in § 2.2. Downstream of the puff (right-hand part of figure 9), the sampled gas is seen to creep along the hot boundary layer, but it fills only a small part of the total circumference. Figure 10 shows the mean mass fraction of CO2 in the outlet section. The end plate of the dilution tube acts as an obstacle which causes high turbulence, as expected from figure 2. The mixing here is much better than in the preceding part of the dilution tube, but it is not complete, hence there remains a concentration difference of approximately 20 % in the two outlets. The creeping sample gas flow and the final concentration differences are also seen well in the RANS calculations (figure 11).
4.3 Orifice flow rate and DR
Figure 12(a) shows the calculated orifice flow rates for ambient air and hot flame gas. The corresponding discharge coefficients are ${C_{d,calc}} = {Q_{orf,calc}}/{Q_{orf,theoretical}}$, where ${Q_{orf,theoretical}}$ is given by (1), setting ${C_d} = 1.0$. As shown in figure 12(b), for ambient air, the calculated discharge coefficient increases with increasing pressure drop, passes a maximum and drops farther on. This behaviour is in agreement with Reference Berger, Gourdain, Bauerheim and DevillezBerger et al. (2019). For the hot flame gas, surprisingly, the calculated discharge coefficient is only around 0.35, probably because of the increased viscosity and, it appears that the discharge coefficient scales with η −1.75 (broken lines in figure 12b). Together with our previous reports (Reference Mätzing and StapfMätzing & Stapf, 2019; Reference Mätzing, Vlavakis, Trimis and StapfMätzing, Vlavakis, Trimis, & Stapf, 2022), the present study seems to be the first attempt to investigate the orifice flow at high temperature by CFD and, no comparable investigation was found in the literature.
Figure 12(c) shows the DR for flame conditions which is calculated from figure 12(a) assuming homogeneous mixing (see comment in the discussion section). At the DMA outlet, DR = 2160 at ΔP = 100 Pa and orifice diameter Dorf = 0.3 mm. Reference Zhao, Yang, Wang, Johnston and WangZhao, Yang, Wang, et al. (2003) reported DR = 2 × 104 at ΔP = 100 Pa for an orifice diameter of 0.2 mm. If the reported DR is normalized to Dorf = 0.3 mm via the ratio of orifice cross-sections, it drops to 8900, which is still much higher than calculated here. Similarly, if the present data are extrapolated to the conditions of Reference Camacho, Liu, Gu, Lin, Huang, Tang and WangCamacho et al. (2015) and Reference Abid, Heinz, Tolmachoff, Phares, Campbell and WangAbid et al. (2008), wherein Dorf = 0.127 mm, ΔP = 980 Pa, a DR of 130 is obtained, well below the reported DR, which are 450 and 620, respectively.
4.4 Embedded dilution tubes
As mentioned in the introduction, many studies of the soot formation zone employ cooled stagnation plates for flame stabilization which have embedded dilution tubes. The major difference to free-standing tubes is the much more intense cooling of the postflame gas and the tube wall down to temperatures as low as 400 K. Under these conditions, the cross-sectional gradients of viscosity and Reynolds number are smaller than in free-standing dilution tubes, which should favour the mixing process. On the other hand, the diffusion coefficient (∝ T 3/2) is reduced by a factor of 3.75 which is disadvantageous for the mixing process under low turbulence conditions.
Figure 13 shows the calculated concentration profiles, ${y_{\textrm{C}{\textrm{O}_2}}}$, in the middle and in the outlet sections. Due to the smaller temperature difference between the inert dilution gas and the sampled gas (as well as the wall temperature), the mixing process improves somewhat and, the calculated concentration difference at the DMA and pump outlets is only 5 %. The DR, however, is only DR = 412 for a pressure drop of ΔP = 100 Pa, which is well below usual reports of experimental studies (Reference Abid, Heinz, Tolmachoff, Phares, Campbell and WangAbid et al., 2008; Reference Camacho, Liu, Gu, Lin, Huang, Tang and WangCamacho et al., 2015; Reference Tang, Mei and YouTang et al., 2016).
5. Discussion
The gas flow and the mixing process in horizontal dilution tubes are difficult to investigate experimentally. Therefore, RANS calculations and LES were used here to test the important claims of the procedure, which are rapid mixing and quenching of the flame gas sample. The calculations were performed on two high resolution grids and grid independence was confirmed.
As first result, the Re number was found to decrease rapidly along the tube axis and the gas flow is shifted from the initial turbulent into the transitional flow regime. In terms of macroscopic gas properties, this is due to increasing gas temperature and to the associated increase of gas viscosity. On the microscale, it is due a specific turbulent dissipation rate around 4000 s−1 which translates into a relaxation time ∼250 μs and a relaxation length scale ∼4 mm only. Consequently, at the orifice location, the radial velocity profile is neither flat (as in turbulent conditions) nor is it parabolic (as in laminar case), which indicates transitional flow.
Farther downstream, significant turbulent structures develop close to the end plate of the dilution tube, where the gas flow is split into two outlet pipes with smaller diameters than in the main body of the dilution tube. In the pump outlet, the Re number is >2 × 104 and the gas flow is clearly turbulent. In the DMA outlet, which carries only approximately 5 % of the total gas flow, the Re number is low (∼800), but the trajectories are not straight and in parallel, as in laminar flow. Instead, they appear meandering, oscillating between different locations of the wall. This means that turbulent structures persist in the DMA outlet. Moreover, this situation is disadvantageous for undisturbed, reliable and reproducible gas and particle sampling.
The gas flow through the sampling orifice was interpreted in terms of a jet in cross-flow configuration. Under ambient air conditions, which correspond to the calibration procedure in experimental studies, the discharge coefficient at the orifice was found to be in the range 0.6–1.2 and to pass a maximum at a pressure drop ΔP ≈ 150 Pa, in agreement with previous literature data (Reference Berger, Gourdain, Bauerheim and DevillezBerger et al., 2019). Under the hot (1000 K) conditions met in free-standing dilution tubes, the discharge coefficient dropped to values below 0.4. This is probably due to increased viscosity, and a correlation ${C_d} \propto {\eta ^{ - 1.75}}$ appears to explain the results.
Based on these results, the DR was determined assuming homogeneous dilution in the inert gas flow. In agreement with experimental results, the DR was found to decrease almost exponentially with increasing pressure drop. However, the experimental DR often depend on some assumption about the nature of the orifice flow and the accuracy is limited roughly to a factor of three (Reference Abid, Heinz, Tolmachoff, Phares, Campbell and WangAbid et al., 2008; Reference Camacho, Liu, Gu, Lin, Huang, Tang and WangCamacho et al., 2015). In addition, experimental DR have a tendency to turn out too high because of eventual clogging which decreases the orifice size. The uncertainties associated with clogging are also approximately a factor of three in DR (Reference Abid, Heinz, Tolmachoff, Phares, Campbell and WangAbid et al., 2008). As shown above, the DR calculated here are significantly smaller than those given in literature reports, both for free-standing and for embedded dilution tubes. They are approximately a factor of five below reported averages and fall below the reported lower limits.
Most importantly, for both free-standing and embedded dilution tubes, the mixing process was found to be incomplete at the available time scale. Therefore, significant concentration gradients persist and do not cancel out in the outlets. In case of the much hotter gas samples of free-standing dilution tubes, this effect is more pronounced than in the intensively cooled embedded dilution tubes. This also means that DR which are based on the assumption of complete, homogeneous mixing can only be regarded as rough estimates. A separate test calculation was performed with much higher dilution gas flow, in a way that the Reynolds number increased to 2 × 104 in the main body of the dilution tube. But even then, the mixing process was still incomplete in the outlet section. A more careful experimental testing of the performance of horizontal dilution tubes is recommended, e.g. using test gas samples and test aerosol particles of known size distribution.
To improve the performance of horizontal dilution tubes, it appears that the jet-to-cross-flow momentum flux ratio should be increased, either by applying a higher pressure drop at the orifice or by reducing the dilution gas flow rate. In addition, small obstacles might be installed in the tube upstream of the orifice, in order to increase the turbulence intensity in a similar way as it is now occurring at the tube outlets. Also, a dilution gas of low viscosity and/or high diffusivity may improve the mixing process.
6. Conclusions
Horizontal dilution tubes are widely used for flame gas and particle sampling. The present CFD analysis focuses on the cooling and mixing processes inside the dilution tubes. Grid independence and validity of RANS results were confirmed. Therefore, while LES helps us to understand the flow properties on the microscale, RANS calculations have proved to be reliable tools for the assessment of the overall performance of horizontal dilution tubes. A major advantage of the CFD approach is to calculate DR without particular assumptions about the nature of the orifice flow. The results show that the turbulence of the dilution gas flow and the jet to cross-flow momentum flux ratio are too low to ensure high mixing and quenching rates at the time scales available.
Experimental set-ups may differ from the case which is studied here. In a similar previous study (Reference Mätzing and StapfMätzing & Stapf, 2019), the tube diameter was a factor of two smaller, the material was stainless steel and the outlets were perpendicular to each other. The major results, however, were quite comparable to those reported here. Therefore, differences in absolute dimensions, tube materials and configuration are expected to be of minor importance. While the reported experimental DR have uncertainties around a factor of three, the DR were calculated here to be roughly a factor of five below reported averages. But also, the mixing process was found to be incomplete. Therefore, the concept of a well-defined DR appears questionable and, the experimental procedure needs improvement.
This study has also shown that there are only limited literature data available about high-temperature orifice flows.
Future studies, both experimental and theoretical, should be undertaken to optimize the performance of horizontal dilution tubes in terms of accurate and reliable sampling. According to the jet in cross-flow concept, this can be achieved by proper adjustment of the gas flow rates. The major drawback is the low turbulence in the vicinity of the sampling orifice. It may be increased by a more appropriate design of the dilution tubes. In addition, the installation of flow resistors may help to increase the turbulence of the dilution gas flow.
Acknowledgements
Helpful discussions with A. Loukou (formerly at KIT) and with T. Zirwes at KIT are gratefully acknowledged.
Funding
The authors gratefully acknowledge the financial support by the Helmholtz Association of German Research Centres (HGF), especially in the Program ‘Energy Efficiency, Materials and Resources’.
Competing Interests
The authors report no conflict of interest.
Data availability statement