Hostname: page-component-586b7cd67f-gb8f7 Total loading time: 0 Render date: 2024-11-25T22:09:56.276Z Has data issue: false hasContentIssue false

Evaluation of the PhysioFlex™ closed-circuit anaesthesia machine

Published online by Cambridge University Press:  16 August 2006

A. Suzuki
Affiliation:
Department of Anesthesiology and Intensive Care, Hamamatsu University School of Medicine, 3600 Handa-cho, Hamamatsu, 431–3192 Japan
H. Bito
Affiliation:
Department of Anesthesiology and Intensive Care, Hamamatsu University School of Medicine, 3600 Handa-cho, Hamamatsu, 431–3192 Japan
Y. Sanjo
Affiliation:
Department of Anesthesiology and Intensive Care, Hamamatsu University School of Medicine, 3600 Handa-cho, Hamamatsu, 431–3192 Japan
T. Katoh
Affiliation:
Department of Anesthesiology and Intensive Care, Hamamatsu University School of Medicine, 3600 Handa-cho, Hamamatsu, 431–3192 Japan
S. Sato
Affiliation:
Department of Anesthesiology and Intensive Care, Hamamatsu University School of Medicine, 3600 Handa-cho, Hamamatsu, 431–3192 Japan
Get access

Abstract

The concentrations of nitrous oxide, sevoflurane and oxygen in the circle system of a closed-circuit anaesthesia machine, the PhysioFlex™, were measured in seven patients. During anaesthesia, the settings for each gas were changed and their concentrations recorded. At the induction of anaesthesia, it took 80– 510s (median 190 s) for the end-tidal sevoflurane concentration to reach 2.0%, and 920–2640 s (median 1500 s) for the oxygen in the breathing circuit to reach 30%. At this time, the nitrous oxide concentration was 60±3% (mean±SD). During anaesthesia, it took 90–480 s (median 140 s) for the end-tidal sevoflurane concentration setting to decrease from 3.0 to 1.0%, and 90–400 s (median 110 s) to return from 1.0 to 3.0%. When the inspired oxygen was increased from 30 to 50%, circuit concentrations reached equilibrium in 40–60 s (median 40 s), and when decreased from 50% back to 30%, equilibrium took 310–470 s (median 450 s). During recovery from anaesthesia, inspiratory sevoflurane concentration took 40–70 s (median 50 s) to decrease to 0.2%. The PhysioFlex™ provided adequate control of sevoflurane and oxygen concentrations, but not of increasing nitrous oxide concentrations.

Type
Original Article
Copyright
2000 European Society of Anaesthesiology

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)