Hostname: page-component-586b7cd67f-gb8f7 Total loading time: 0 Render date: 2024-11-23T01:22:24.384Z Has data issue: false hasContentIssue false

Preload and haemodynamic assessment during liver transplantation: a comparison between the pulmonary artery catheter and transpulmonary indicator dilution techniques

Published online by Cambridge University Press:  16 August 2006

G. Della Rocca
Affiliation:
University of Rome ‘La Sapienza’, Istituto di Anestesiologia e Rianimazione, Azienda Ospedaliera Policlinico Umberto I, Roma, Italy
M. G. Costa
Affiliation:
University of Rome ‘La Sapienza’, Istituto di Anestesiologia e Rianimazione, Azienda Ospedaliera Policlinico Umberto I, Roma, Italy
C. Coccia
Affiliation:
University of Rome ‘La Sapienza’, Istituto di Anestesiologia e Rianimazione, Azienda Ospedaliera Policlinico Umberto I, Roma, Italy
L. Pompei
Affiliation:
University of Rome ‘La Sapienza’, Istituto di Anestesiologia e Rianimazione, Azienda Ospedaliera Policlinico Umberto I, Roma, Italy
P. Pietropaoli
Affiliation:
University of Rome ‘La Sapienza’, Istituto di Anestesiologia e Rianimazione, Azienda Ospedaliera Policlinico Umberto I, Roma, Italy
Get access

Abstract

Background and objective: Liver transplantation is characterized by several changes in intravascular blood volume due to vasodilatation based on neurohumoral mediators, intraoperative bleeding and anaesthesia technique effects. Today, with the transpulmonary indicator dilution technique, cardiac index (CIart) can be evaluated and preload assessed in terms of the intrathoracic blood volume index (ITBVI). The aim was to analyse in patients undergoing liver transplantation two preload variables, pulmonary artery occlusion pressure (PAOP) and ITBVI with respect to cardiac index (CIpa) and stroke volume index (SVIpa), the correlation between ITBVI and PAOP, and secondary the relationship between the changes (Δ) of ITBVI and PAOP and the changes of CIpa and SVIpa, and the relationships between ΔITBVI and ΔPAOP. The reproducibility and precision of all CIart and CIpa measurements were also evaluated.

Methods: A prospective study was performed in 60 patients monitored with a pulmonary artery catheter and with the PiCCO® system. The variables were evaluated with a linear regression model.

Results: Linear regression analysis between ITBVI-CIpa and ITBVI-SVIpa were r2 = 0.47 (P < 0.0001) and r2 = 0.55 (P < 0.0001) respectively, while PAOP poorly correlated to CIpa (r2 = 0.02), SVIpa (r2 = 0.015) and ITBVI (r2 = 0.002). Only changes in ITBVI were correlated with changes in CIpa (Δ1, r2 = 0.37; Δ2, r2 = 0.32), and SVIpa (Δ1, r2 = 0.60; Δ2, r2 = 0.47). The mean bias between CIart and CIpa was 0.13 L min−1 m−2 (2 SD = 1.04 L min−1m−2) (r2 = 0.86, P < 0.0001).

Conclusions: In comparison with PAOP, ITBVI seems a more reliable indicator of cardiac preload in patients undergoing liver transplantation.

Type
Original Article
Copyright
2002 European Society of Anaesthesiology

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)