Hostname: page-component-cd9895bd7-7cvxr Total loading time: 0 Render date: 2024-12-23T14:21:28.142Z Has data issue: false hasContentIssue false

Pharmacodynamic interaction of nitrous oxide with sevoflurane, desflurane, isoflurane and enflurane in surgical patients: measurements by effects on EEG median power frequency

Published online by Cambridge University Press:  16 August 2006

H. Röpcke
Affiliation:
Department of Anaesthesiology and Intensive Care Medicine, University of Bonn, D-53123, Germany
S. Wirz
Affiliation:
Department of Anaesthesiology and Intensive Care Medicine, University of Bonn, D-53123, Germany
T. Bouillon
Affiliation:
Department of Anaesthesiology and Intensive Care Medicine, University of Bonn, D-53123, Germany
J. Bruhn
Affiliation:
Department of Anaesthesiology and Intensive Care Medicine, University of Bonn, D-53123, Germany
A. Hoeft
Affiliation:
Department of Anaesthesiology and Intensive Care Medicine, University of Bonn, D-53123, Germany
Get access

Abstract

Background and objective This study investigates the interaction of sevoflurane and nitrous oxide on EEG median power frequency of 2.5 Hz during surgery.

Methods Sevoflurane concentrations required for electroencephalographic median power frequency between 2 and 3 Hz were measured in 25 patients during gynaecological laparotomies. Nitrous oxide was randomly administered at 0, 20, 40, 60 and 75 vol%, subsequently two different concentrations in each patient. The data were analysed using isobolographic analysis together with previously published data on nitrous oxide-isoflurane, -enflurane, or -desflurane interaction.

Results The interaction is described by the equation: C volatile anaesthetic/C0 volatile anaesthetic + C N2O/C0 N2O = 1 (C is the concentrations for a drug combination to achieve the desired effect; C0 is the concentration for single drug use). The parameters are C0 isoflurane = 1.11 vol% (95% CI 1.03–1.19), C0 enflurane = 1.64 (1.52–1.77), C0 desflurane = 5.31 (4.92–5.73), C0 sevoflurane = 2.12 (1.96–2.29), C0 N2O = 174 (153–202). These parameters decrease by 6% (2.5–10) for every 10 years of patients’ age > 40 years.

Conclusions The interaction is compatible with additivity. The potency of nitrous oxide to substitute the volatile anaesthetics is less than anticipated from previously reported MAC values.

Type
Original Article
Copyright
2001 European Society of Anaesthesiology

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)