Hostname: page-component-cd9895bd7-dk4vv Total loading time: 0 Render date: 2024-12-24T13:01:16.989Z Has data issue: false hasContentIssue false

Management of difficult intubation

Published online by Cambridge University Press:  16 August 2006

M. Janssens
Affiliation:
Department of Anesthesiology, University Hospital of Liege, Belgium
G. Hartstein
Affiliation:
Department of Anesthesiology, University Hospital of Liege, Belgium
Get access

Abstract

Appropriate airway management is an essential part of the anaethetist's role. Difficult intubation, which can now be quantified using the ‘Intubation Difficulty Scale’, should be anticipated whenever possible. A strategy needs to be developed in order to anticipate problems. The first part of this paper reviews the different factors that contribute to make intubation and/or ventilation difficult. Problems with intubation (or ventilation of the lungs) can be caused by abnormal laryngeal structures (e.g. tumour, stenosis), or by difficulty in seeing the glottis. The clinical history will usually help identify the former problem, while physical examination of the airway is required to reveal either disproportion between the various structures of the airway (e.g. tongue, larynx), and/or difficulties in aligning the oral, pharyngeal, and laryngeal axes. The different techniques used to diagnose these problems are described. The second part of this paper summarizes the algorithms used by the anaesthetist when management of the airway is found difficult. Three situations are considered: (a) anticipated difficult intubation, for which awake fibreoptic intubation would appear to be the technique of choice in the majority of cases, (b) unforeseen difficult intubation in a patient whose lungs can be ventilated; here, various techniques for control of the airway will be briefly described, and (c) both tracheal intubation and lung ventilation are impossible; this is a life-threatening emergency, for which three solutions are proposed. These include use of the laryngeal mask airway, the Combi-tube®, or transtracheal ventilation. These situations will be analysed with the aim of proposing management strategies that always guarantee the safety of the patient.

Type
FEAA Review Article
Copyright
2001 European Society of Anaesthesiology

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)