Hostname: page-component-cd9895bd7-dk4vv Total loading time: 0 Render date: 2024-12-24T02:45:45.302Z Has data issue: false hasContentIssue false

Kinetic analysis of cardiac troponin I release is no more accurate than a single 24-h measurement in predicting in-hospital outcome after cardiac surgery

Published online by Cambridge University Press:  01 June 2008

J.-L. Fellahi*
Affiliation:
Centre Hospitalier Privé Saint-Martin, Departments of Anesthesiology, Biology, Cardiothoracic Surgery, Caen, Paris, France
J.-L. Hanouz
Affiliation:
Centre Hospitalier Régional Universitaire, Department of Anesthesiology, Critical Care and Prehospital Medicine, Caen, Paris, France
X. Gué
Affiliation:
Centre Hospitalier Privé Saint-Martin, Departments of Anesthesiology, Biology, Cardiothoracic Surgery, Caen, Paris, France
E. Monier
Affiliation:
Centre Hospitalier Privé Saint-Martin, Departments of Anesthesiology, Biology, Cardiothoracic Surgery, Caen, Paris, France
L. Guillou
Affiliation:
Centre Hospitalier Privé Saint-Martin, Departments of Anesthesiology, Biology, Cardiothoracic Surgery, Caen, Paris, France
B. Riou
Affiliation:
CHU Pitié-Salpêtrière, Assistance Publique-Hôpitaux de Paris, Department of Emergency Medicine, Paris, France
*
Service d’Anesthésie Réanimation, CHP Saint-Martin, 18 rue des Roquemonts, 14050 Caen Cedex 4, France. E-mail: [email protected]; Tel: +33 231 433 120; Fax: +33 231 433 124.
Get access

Summary

Background and objective

A single cardiac troponin I (cTnI) 24-h measurement is an independent predictor of short- and long-term adverse outcome after coronary surgery. We compared a single cTnI 24-h measurement and kinetic analysis of cTnI release in predicting in-hospital outcome in unselected cardiac surgery patients.

Methods

Consecutive patients (n = 184) undergoing cardiac surgery with cardiopulmonary bypass were included and divided into two groups according to the time course of postoperative peak serum cTnI (6 or 24 h after surgery). Serial measurements of cTnI were performed the day before surgery, at the end of surgery and 6, 24 and 120 h after surgery in all patients. The total amount of cTnI released (integrated area under the curve), postoperative major adverse cardiac events (ventricular arrhythmias, myocardial infarction and congestive heart failure) and in-hospital death were recorded. Data are expressed as median (95% CI).

Results

In all, 152 (83%) patients had an early peak cTnI (6 h after surgery) and 32 (17%) patients had a late peak cTnI (24 h after surgery). The integrated area under the curve differed between both groups: 159 (142–178) vs. 321 (255–590), respectively, P < 0.001. Major adverse cardiac events and/or death (22 vs. 9%, P = 0.04) was greater in patients with a late peak cTnI. The integrated area under the curve and the peak value of cTnI were no more accurate than a single 24-h measurement in predicting the occurrence of major adverse cardiac events and/or death.

Conclusions

Kinetic analysis of cTnI release was no more accurate than a single 24-h measurement in predicting in-hospital poor outcome.

Type
Original Article
Copyright
Copyright © European Society of Anaesthesiology 2008

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1.Jaffe, AS, Ravkilde, J, Roberts, R et al. It’s time for a change to a troponin standard. Circulation 2000; 102: 12161220.CrossRefGoogle ScholarPubMed
2.Le Manach, Y, Perel, A, Coriat, P, Godet, G, Bertrand, M, Riou, B. Early and delayed myocardial infarction following aortic surgery. Anesthesiology 2005; 102: 885891.CrossRefGoogle Scholar
3.Luepker, RV, Apple, FS, Christenson, RH et al. Case definitions for acute coronary heart disease in epidemiology and clinical research studies: a statement from the AHA Council on Epidemiology and Prevention; AHA Statistics Committee; World Heart Federation Council on Epidemiology and Prevention; the European Society of Cardiology Working Group on Epidemiology and Prevention; Centers for Disease Control and Prevention; and the National Heart, Lung, and Blood Institute. Circulation 2003; 108: 25432549.CrossRefGoogle Scholar
4.Alyanakian, MA, Dehoux, M, Chatel, D et al. Cardiac troponin I in diagnosis of perioperative myocardial infarction after cardiac surgery. J Cardiothorac Vasc Anesth 1998; 11: 288294.CrossRefGoogle Scholar
5.Fellahi, JL, Léger, P, Philippe, E et al. Pericardial cardiac troponin I release after coronary artery bypass grafting. Anesth Analg 1999; 89: 829834.Google ScholarPubMed
6.Carrier, M, Pellerin, M, Perrault, LP, Solymoss, BC, Pelletier, LC. Troponin levels in patients with myocardial infarction after coronary artery bypass grafting. Ann Thorac Surg 2000; 69: 435440.CrossRefGoogle ScholarPubMed
7.Dehoux, M, Provenchère, S, Benessiano, J et al. Utility of cardiac troponin measurement after cardiac surgery. Clin Chim Acta 2001; 311: 4144.CrossRefGoogle ScholarPubMed
8.Lasocki, S, Provenchère, S, Benessiano, J et al. Cardiac troponin I is an independent predictor of in-hospital death after adult cardiac surgery. Anesthesiology 2002; 97: 405411.CrossRefGoogle ScholarPubMed
9.Fellahi, JL, Hédoire, F, Le Manach, Y, Monier, E, Guillou, L, Riou, B. Determination of the threshold of cardiac troponin I associated with an adverse postoperative outcome after cardiac surgery: a comparative study between coronary artery bypass graft, valve, and combined cardiac surgery. Critical Care 2007; 11: R106.CrossRefGoogle ScholarPubMed
10.Etievent, JP, Chocron, S, Toubin, G et al. Use of cardiac troponin I as a marker of perioperative myocardial ischemia. Ann Thorac Surg 1995; 59: 11921194.CrossRefGoogle ScholarPubMed
11.Vermes, E, Mesguish, M, Houel, R et al. Cardiac troponin I release after open heart surgery: a marker of myocardial protection? Ann Thorac Surg 2000; 70: 20872090.CrossRefGoogle ScholarPubMed
12.Salamonsen, RF, Schneider, HG, Bailey, M, Taylor, AJ. Cardiac troponin I concentrations, but not electrocardiographic results, predict an extended hospital stay after coronary artery bypass graft surgery. Clin Chem 2005; 51: 4046.CrossRefGoogle Scholar
13.Fellahi, JL, Gué, X, Richomme, X, Monier, E, Guillou, L, Riou, B. Short and long-term prognostic value of postoperative cardiac troponin I concentration in patients undergoing coronary artery bypass grafting. Anesthesiology 2003; 99: 270274.CrossRefGoogle Scholar
14.Greenson, N, Macoviak, J, Krishnaswamy, P et al. Usefulness of cardiac troponin I in patients undergoing open heart surgery. Am Heart J 2001; 141: 447455.CrossRefGoogle ScholarPubMed
15.Fellahi, JL, Gué, X, Philippe, E, Riou, B, Gérard, JL. Isoflurane may not influence postoperative cardiac troponin I release and clinical outcome in adult cardiac surgery. Eur J Anaesthesiol 2004; 21: 688693.CrossRefGoogle Scholar
16.Ouattara, A, Lecomte, P, Le Manach, Y et al. Poor intraoperative blood glucose control is associated with a worsened hospital outcome after cardiac surgery in diabetic patients. Anesthesiology 2005; 103: 687694.CrossRefGoogle ScholarPubMed
17.Le Manach, Y, Godet, G, Coriat, P et al. The impact of postoperative discontinuation or continuation of chronic statin therapy on cardiac outcome after major vascular surgery. Anesth Analg 2007; 104: 13261333.CrossRefGoogle ScholarPubMed
18.Le Gall, JR, Loirat, P, Alperovitch, A et al. A simplified acute physiology score for ICU patients. Crit Care Med 1984; 12: 975977.CrossRefGoogle ScholarPubMed
19.Provenchère, S, Plantefève, G, Hufnagel, G et al. Renal dysfunction after cardiac surgery with normothermic cardiopulmonary bypass: incidence, risk factors and effect on clinical outcome. Anesth Analg 2003; 96: 12581264.CrossRefGoogle ScholarPubMed
20.Hanley, JA, McNeil, BJ. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 1982; 143: 2936.CrossRefGoogle Scholar
21.Hanley, JA, McNeil, BJ. A method of comparing the areas under receiver operating characteristics curves derived from the same cases. Radiology 1983; 148: 839843.CrossRefGoogle ScholarPubMed
22.Benoit, MO, Paris, M, Silleran, J, Fiemeyer, A, Moatti, N. Cardiac troponin I: its contribution to the diagnosis of perioperative myocardial infarction and various complications of cardiac surgery. Crit Care Med 2001; 29: 18801886.CrossRefGoogle Scholar
23.Holmvang, L, Jurlander, B, Rasmussen, C, Thiis, JJ, Grande, P, Clemmensen, P. Use of biochemical markers of infarction for diagnosing perioperative myocardial infarction and early graft occlusion after coronary artery bypass grafting. Chest 2002; 121: 103111.CrossRefGoogle Scholar
24.Birdi, I, Caputo, M, Hutter, JA, Bryan, AJ, Angelini, GD. Troponin I release during minimally invasive coronary artery surgery. J Thorac Cardiovasc Surg 1997; 114: 509510.CrossRefGoogle ScholarPubMed