Hostname: page-component-cd9895bd7-7cvxr Total loading time: 0 Render date: 2024-12-24T05:08:55.364Z Has data issue: false hasContentIssue false

Arterial to end-tidal carbon dioxide tension difference in anaesthetized adults mechanically ventilated via a laryngeal mask or a cuffed oropharyngeal airway

Published online by Cambridge University Press:  16 August 2006

A. Casati
Affiliation:
University of Milan, Department of Anaesthesiology, IRCCS H San Raffaele, Milan, Italy
G. Fanelli
Affiliation:
University of Milan, Department of Anaesthesiology, IRCCS H San Raffaele, Milan, Italy
G. Cappelleri
Affiliation:
University of Milan, Department of Anaesthesiology, IRCCS H San Raffaele, Milan, Italy
A. Albertin
Affiliation:
University of Milan, Department of Anaesthesiology, IRCCS H San Raffaele, Milan, Italy
D. Anelati
Affiliation:
University of Milan, Department of Anaesthesiology, IRCCS H San Raffaele, Milan, Italy
L. Magistris
Affiliation:
University of Milan, Department of Anaesthesiology, IRCCS H San Raffaele, Milan, Italy
G. Torri
Affiliation:
University of Milan, Department of Anaesthesiology, IRCCS H San Raffaele, Milan, Italy
Get access

Abstract

To evaluate arterial (PaCO2), end-tidal (PETCO2) and carbon dioxide tension difference during mechanical ventilation with extratracheal airways, 60 patients ASA physical status I-II, receiving general anaesthesia for minor extra-abdominal procedures were randomly allocated to receive either a cuffed oropharyngeal airway (group COPA, n=30) or a laryngeal mask (group LMA, n=30). The lungs were mechanically ventilated by IPPV using a 60% nitrous oxide and 1–1.5% isoflurane in oxygen mixture (VT8 mL kg−1; RR=12 b min−1; I/E=1/2). After PETCO2 had been stable for at least 10 min after airway placement, haemodynamic variables and PETCO2 were recorded and an arterial blood sample was obtained for measurement of PaCO2. No differences in anthropometric parameters, smoking habit, haemodynamic variables and incidence of untoward events were observed between the two groups. Airway manipulation, to maintain adequate ventilation, was required in only nine patients in the cuffed oropharyngeal airway group (30%)(P < 0.0005); however,in no case was it necessary to remove the designated extratracheal airway due to unsuccessful mechanical ventilation. The mean difference between arterial and end-tidal carbon dioxide partial pressure was 0.4±0.3 KPa in the laryngeal mask group (95% confidence intervals: 0.3–0.5 KPa) and 0.3±0.26 KPa in the cuffed oropharyngeal airway group (95% confidence intervals: 0.24–0.4 KPa) (P =NS). We conclude that in healthy adults who are mechanically ventilated via the cuffed oropharyngeal airway, the end-tidal carbon dioxide determination is as accurate an indicator of PaCO2 as that measured via the laryngeal mask, allowing capnometry to be reliably used to evaluate the adequacy of ventilation.

Type
Original Article
Copyright
1999 European Society of Anaesthesiology

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)