Hostname: page-component-586b7cd67f-l7hp2 Total loading time: 0 Render date: 2024-11-23T02:58:21.321Z Has data issue: false hasContentIssue false

Comparison of ventilation during exercise in horses wearing half- and full-face masks

Published online by Cambridge University Press:  09 March 2007

D.J. Marlin*
Affiliation:
Equine Centre, Faculty of Medical and Veterinary Sciences, University of Bristol, Langford, UK
V. Adams
Affiliation:
Preventive Medicine, Animal Health Trust, Lanwades Park, Kentford, Newmarket, Suffolk CB8 7UU, UK
A. Greenwood
Affiliation:
Writtle College, Lordship Lane, Writtle, Essex, UK
E. Case
Affiliation:
Writtle College, Lordship Lane, Writtle, Essex, UK
M. Roberts
Affiliation:
Writtle College, Lordship Lane, Writtle, Essex, UK
C.M. Deaton
Affiliation:
Equine Centre, Faculty of Medical and Veterinary Sciences, University of Bristol, Langford, UK
*
*Corresponding author: [email protected]
Get access

Abstract

Several studies have shown that the placement of a face mask on a horse can have effects on ventilation, gas exchange and the cardiovascular system during exercise. The aim of the present study was to determine if airflow and ventilation measured with the same ultrasonic flowmeters were different during exercise between horses wearing half- (HM) and full-face (FM) masks. Five clinically healthy Thoroughbred horses with no history of respiratory disease were studied in an unbalanced crossover design. They were exercised on a treadmill at speeds between 1.7 and 11ms−1 on a 3° incline wearing both masks. The following variables were recorded: peak inspired (PIF) and peak expired flow rates (PEF), inspiratory tidal volume (VT), respiratory rate (fR ), inspiratory minute ventilation (VE), inspiratory time, (TI), expiratory time (TE ), total breath time (TT), end tidal oxygen (ETO2), end tidal carbon dioxide (ETCO2) and heart rate (HR). A mask by speed of exercise interaction term was not significant for any of the models. The PEF (mean difference 12.91s−1; lower and upper 95% CI 7.6 and 18.21s−1, respectively; P<0.0001) and ETO2 (mean difference 0.77%; lower and upper 95% CI 0.48 and 1.00%, respectively; P<0.0001) were significantly greater and ETCO2 was significantly lower (mean difference −1.3%; lower and upper 95% CI −2.0 and 0.7%, respectively; P<0.0001) with the FM compared with the HM. There was also a trend for inspired VE to be higher with the FM compared with the HM (mean difference 1021min−1; lower and upper 95% CI 26 and 1781 min−1, respectively; non-significant). We conclude that the HM may impair ventilation in the horse during exercise compared with the FM, despite the latter having a greater deadspace.

Type
Research Article
Copyright
Copyright © Cambridge University Press 2006

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1Evans, DL and Rose, RJ (1988). Effect of a respiratory gas collection mask on some measurements of cardiovascular and respiratory function in horses exercising on a treadmill. Research in Veterinary Science 44(2): 220225.CrossRefGoogle ScholarPubMed
2Butler, PJ, Woakes, AJ, Smales, K, Roberts, CA, Hillidge, CJ, Snow, DH and Marlin, DJ (1993). Respiratory and cardiovascular adjustments during exercise of increasing intensity and during recovery in thoroughbred racehorses. The Journal of Experimental Biology 179, 159180.CrossRefGoogle ScholarPubMed
3Holcombe, SJ, Beard, WL and Hinchcliff, KW (1996). Effect of a mask and pneumotachograph on tracheal and nasopharyngeal pressures, respiratory frequency, and ventilation in horses. American Journal of Veterinary Research 57(3): 250253.CrossRefGoogle ScholarPubMed
4Gauvreau, GM, Young, SS, Staempfli, H, McCutcheon, LJ, Wilson, BA and McDonell, WN (1996). The relationship between respiratory exchange ratio, plasma lactate and muscle lactate concentrations in exercising horses using a valved gas collection system. Canandian Journal of Veterinary Research 60(3): 161171.Google ScholarPubMed
5Bayly, WM, Schultz, DA, Hodgson, DR and Gollnick, PD (1987). Ventilatory responses of the horse to exercise: effect of gas collection systems. Journal of Applied Physiology 63(3): 12101217.CrossRefGoogle ScholarPubMed
6Bayly, WM, Slocombe, RF, Weidner, JP, Schott, HC II and Hodgson, DR (1994). Influence of air movement, facemask design and exercise on upper airway, transpulmonary, and transdiaphragmatic pressures in thoroughbred horses. Cornell Veterinary 84(1): 7790.Google ScholarPubMed
7Derksen, FJ, Stick, JA, Scott, EA, Robinson, NE and Slocombe, RF (1986). Effect of laryngeal hemiplegia and laryngoplasty on airway flow mechanics in exercising horses. American Journal of Veterinary Research 47(1): 1620.Google ScholarPubMed
8Shappell, KK, Derksen, FJ, Stick, JA and Robinson, NE (1988). Effects of ventriculectomy, prosthetic laryngoplasty, and exercise on upper airway function in horses with induced left laryngeal hemiplegia. American Journal of Veterinary Research 49(10): 17601765.Google ScholarPubMed
9Bayly, WM, Redman, MJ and Sides, RH (1999). Effect of breathing frequency and airflow on pulmonary function in high-intensity equine exercise. Equine Veterinary Journal Supplement 30, 1923.CrossRefGoogle Scholar
10Hornicke, H, Meixner, R and Pollman, U (1983). Respiration in exercising horses. In: Snow, DH, Persson, SGB and Rose, RJ (eds). Equine Exercise Physiology. Cambridge, UK: Granta Editions.Google Scholar
11Kimmich, HP and Spaan, JG (1980). Combined flow and PO2 sensors for telemetric assessment of oxygen uptake in horses. In: Matsumoto, VG, Kimmich, HP(eds), Biotelemetry Hokkaido, Japan: Matsumoto (pp. 165168).Google Scholar
12Woakes, AJ, Butler, PJ and Snow, DH (1987). The measurement of respiratory airflow in exercising horses. In: Gillespie, JR and Robinson, NE(eds) Equine Exercise Physiology II. San Diego, CA: ICEEP Publications.Google Scholar
13Beadle, RE, Guthrie, AJ and Kou, AH (1995). Characterization of a density-corrected ultrasonic pneumotachometer for horses. Journal of Applied Physiology 78(1): 359367.CrossRefGoogle ScholarPubMed
14Kaestner, SB, Marlin, DJ, Roberts, CA, Auer, JA and Lekeux, P (2000). Comparison of the performance of linear resistance and ultrasonic pneumotachometers at rest and during lobeline-induced hyperpnoea. Research in Veterinary Science 68(2): 153159.CrossRefGoogle Scholar