Hostname: page-component-586b7cd67f-dsjbd Total loading time: 0 Render date: 2024-11-25T02:08:33.071Z Has data issue: false hasContentIssue false

The sterilizing capacity of propylene oxide and chlorhexidine diacetate solutions upon pre-injection swabs saturated with propan-2-ol

Published online by Cambridge University Press:  19 October 2009

R. C. Wright
Affiliation:
Everett Medical Products Ltd, 2–10 Commonside East, Mitcham, Surrey
Rights & Permissions [Opens in a new window]

Summary

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

The sporicidal activity of two solutions which have been used in the production of ‘sterile’ pre-injection swabs has been investigated. Propylene oxide (3·4 % w/w) and chlorhexidine diacetate (0·6% w/w), both made up in approximately 65% w/w propan-2-ol, were artificially contaminated with spores of Bacillus subtilis var. niger and swabs were impregnated with these; surviving spores were enumerated at various temperatures and times of storage. Chlorhexidine diacetate had no sporicidal activity, whereas the activity of propylene oxide was dependent on temperature. The former should not be considered a sterilant and the latter can only be considered such if a controlled incubation period at an elevated temperature is employed.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1983

References

REFERENCES

Beeby, M. & Whitehouse, C. E. (1965). A bacterial spore test piece for the control of ethylene oxide sterilisation. Journal of Applied Bacleriology 28, 349360.CrossRefGoogle Scholar
Blanchard, R. O. & Hanlin, R. T. (1973). Effect of propylene oxide treatment on the microflora of pecans. Applied Microbiology 26, 768772.CrossRefGoogle ScholarPubMed
Bruch, C. W. & Koesterer, M. G. (1961). The microbicidal activity of gaseous propylene oxide and its application to powdered or flaked foods. Journal of Food Science 26, 428435.CrossRefGoogle Scholar
Hart, A. & Brown, M. W. (1974). Propylene oxide as a sterilizing agent. Applied Microbiology 28, 10091070.CrossRefGoogle ScholarPubMed
Hart, A. & Ng, S. N. (1975). Effect of temperature on the sterilisation of isopropyl alcohol by liquid propylene oxide. Applied Microbiology 30, 483484.CrossRefGoogle ScholarPubMed
McBean, D. & Johnson, A. A. (1959). Control of spoilage in high-moisture prunes. Food Preservation Quarterly 17, 4851.Google Scholar
Nury, F. S., Miller, M. W. & Brekke, J. E., (1960). Preservative effect of some antimicrobial agents in high-moisture dried fruits. Food Technology 14, 113115.Google Scholar