Hostname: page-component-586b7cd67f-t8hqh Total loading time: 0 Render date: 2024-11-24T21:52:55.708Z Has data issue: false hasContentIssue false

Serological cross-reaction between Legionella pneumophila and Campylobacter in the indirect fluorescent antibody test

Published online by Cambridge University Press:  15 May 2009

T. C. J. Boswell
Affiliation:
Public Health Laboratory, Northern General Hospital, Herries Road, Sheffield S5 7AU, UK
G. Kudesia
Affiliation:
Public Health Laboratory, Northern General Hospital, Herries Road, Sheffield S5 7AU, UK
Rights & Permissions [Opens in a new window]

Summary

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Sera from 50 patients with culture-proven Campylobacter gastroenteritis were examined for the presence of antibodies to Legionella pneumophila. Ten patients (20%) had a positive titre (≥16) as measured by indirect immunofluorescence. Antibodies were detected in only 1 of 36 acute sera but in 10 of 14 (71%) sera obtained more than 10 days after the onset of symptoms. All positive sera contained specific IgM antibodies but specific IgG or IgA could not be detected in any sample. No legionella antibodies could be detected in sera from 42 similar patients with salmonella gastroenteritis. These results were shown to be due to serological cross-reaction between L. pneumophila and Campylobacter.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1992

References

REFERENCES

1.McDade, JE, Shepard, CC, Fraser, DW, et al. Legionnaires' disease: isolation of a bacterium and demonstration of its role in other respiratory disease. N Engl J Med 1977; 297: 1197–203.CrossRefGoogle ScholarPubMed
2.Wilkinson, HW, Farshy, CE, Fikes, BJ, Cruce, DD, Yealy, LP. Measure of immunoglobulin G-. M-. and A- specific titers against Legionella pneumophila and inhibition of titers against nonspecific, gram-negative bacterial antigens in the indirect immunofluorescence test for legionellosis. J Clin Microbiol 1979; 10: 685–9.CrossRefGoogle Scholar
3.Edelstein, PH, McKinney, RM, Meyer, RD, Edelstein, MAC, Krause, CJ, Finegold, SM. Immunologic diagnosis of legionnaires' disease: cross-reactions with anaerobic and mieroaerophilie organisms and infections caused by them. J Infect Dis 1980; 141: 652–5.CrossRefGoogle Scholar
4.Taylor, AG, Harrison, TG, Dighero, MW, Bradstreet, CMP. False positive reactions in the indirect fluorescent antibody test for legionnaires' disease eliminated by use of formolised yolk-sac antigen. Ann Intern Med 1979; 90: 686–89.CrossRefGoogle ScholarPubMed
5.Gray, JJ, Ward, KN, Warren, RE, Farrington, M. Serological cross-reaction between Legionella pneumophila and Citrobacter freundii in indirect immunofluorescence and rapid microagglutination tests. J Clin Microbiol 1991; 29: 200–1.CrossRefGoogle ScholarPubMed
6.Harrison, TG, Taylor, AG. The diagnosis of legionnaires' disease by estimation of antibody levels. In: Harrison, TG, Taylor, AG. eds. A laboratory manual for legionella. Chichester: John Wiley and Sons Ltd. 1988; 113–35.Google Scholar
7.Harrison, TG, Taylor, AG. Diagnosis of Legionella pneumophila infections by means of formolised yolk-sac antigens. J Clin Pathol 1982; 35: 211–4.CrossRefGoogle ScholarPubMed