Hostname: page-component-78c5997874-t5tsf Total loading time: 0 Render date: 2024-11-19T04:35:15.122Z Has data issue: false hasContentIssue false

Protective isolation in a burns unit: the use of plastic isolators and air curtains

Published online by Cambridge University Press:  15 May 2009

E. J. L. Lowbury
Affiliation:
M.R.C. Industrial Injuries and Burns Unit, Birmingham Accident Hospital, Bath Row, Birmingham 15
J. R. Babb
Affiliation:
M.R.C. Industrial Injuries and Burns Unit, Birmingham Accident Hospital, Bath Row, Birmingham 15
Pamela M. Ford
Affiliation:
M.R.C. Industrial Injuries and Burns Unit, Birmingham Accident Hospital, Bath Row, Birmingham 15
Rights & Permissions [Opens in a new window]

Summary

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

The use of plastic isolators and of an ‘air curtain’ isolator for protection of patients against infection was studied in a burns unit.

Preliminary bacteriological tests showed that very few airborne bacteria gained access to a plastic ventilated isolator; even when the filter and pre-filter were removed from the air inflow, settle-plate counts inside the isolator were much lower than those in the open ward, but the difference was smaller in tests made with an Anderson air sampler, which showed also that fewer large bacteria-carrying particles appeared inside the isolator than outside it. An open-topped isolator allowed virtually free access of bacteria from ambient air. The numbers of airborne bacteria inside an air curtain were appreciably lower than the counts of airborne bacteria in the open ward, but not as low as those in the plastic ventilated isolator.

Controlled trials of isolators were made on patients with fresh burns of 4–30 % of the body surface; the patients were given no topical chemoprophylaxis against Staphylococcus aureus or Gram-negative bacilli. Patients treated in plastic isolators showed a significantly lower incidence of infection with Pseudomonas aeruginosa than those treated in the open ward; this protective effect was shown by isolators with or without filters or with an open top. Ventilated isolators, which protected patients against personal contact and airborne infection, gave a limited protection against multi-resistant ‘hospital’ strains of Staph. aureus, but no such protection was given by an open-topped isolator, which protected only against personal contact infection, or by air curtains, which protected only against airborne infection; the air curtain gave no protection against Ps. aeruginosa, and there was no evidence of protection by any isolator against Proteus spp. and coliform bacilli.

Both the controlled trials and evidence from the bacteriology of air, hands, fomites and rectal and nasal swabs taken on admission and later, supported the view that Ps. aeruginosa is transferred mainly by personal contact, Staph. aureus probably by air as well as by contact and coliform bacilli mainly by self infection with faecal flora, many of which are first acquired from the hospital environment in food or on fomites.

The use of plastic isolators is cumbersome, and of limited value except in the control of infection with Ps. aeruginosa. For this reason and because of the effectiveness of topical chemoprophylaxis such isolators are unlikely to have more than an occasional use in the treatment of burns. Though air curtains greatly reduce airborne contamination, their use in a burns unit does not appear to protect patients against infection when the alternative (and, for Ps. aeruginosa, more important) routes of contamination by personal contact and fomites are left open.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1971

References

REFERENCES

Ayliffe, G. A. J, Collins, B. J., Lowbury, E. J. L & Wall, M. (1971). Protective isolation in single-bed rooms: studies in a modified surgical ward. Journal of Hygiene 69, 511.Google Scholar
Barber, M. & Kuper, S. W. A (1951). Identification of Staph. pyogenes by the phosphatase reaction. Journal of Pathology and Bacteriology 63, 65.CrossRefGoogle Scholar
Cason, J. S., Jackson, D. M., Lowbury, E. J. L & Ricketts, C. R. (1966). Antiseptic and aseptic prophylaxis for burns: use of silver nitrate and of isolators. British Medical Journal ii, 1288.CrossRefGoogle Scholar
Colebrook, L. (1950). A New Approach to the Treatment of Burns and Scalds. London: Fine Technical Publications.Google Scholar
Davis, B., Lilly, H. A. & Lowbury, E. J. L (1969). Gram-negative bacilli in burns. Journal of Clinical Pathology 22, 634.CrossRefGoogle ScholarPubMed
Fisher, R. A. & Yates, F. (1948). Statistical Tables for Biological, Agricultural and Medical Research, Table VIII, p. 47. 3rd EditionLondon.Google Scholar
Haynes, B. W. & Hench, M. E. (1966). Total Hospital Isolation Concept and Practice, in Research in Burns, p. 550, ed. Wallace, A. B. and Wilkinson, A. W.. Edinburgh: Livingstone.Google Scholar
Levenson, S. M., del Guercio, L., la Duke, M., Kranz, P., Johnston, M., Alpert, S. & Saltzman, T. (1966). Plastic isolators for special problems of patient care, in Research in Burns, p. 563, ed. Wallace, A. B. and Wilkinson, A. W.. Edinburgh: Livingstone.Google Scholar
Levenson, S. M., Trexler, P. C., la Conte, M. & Pulaski, E. J. (1964). Application of the technology of the germfree laboratory to special problems of patient care. American Journal of Surgery 107, 710.CrossRefGoogle ScholarPubMed
Lidwell, O. M. & Towers, A. G. (1969). Protection from microbial contamination in a room ventilated a unidirectional air flow. Journal of Hygiene 67, 95.Google Scholar
Lowbury, E. J. L (1960). Infection of burns. British Medical Journal i, 994.CrossRefGoogle Scholar
Lowbury, E. J. L (1954). Air conditioning with filtered air for dressing burns. Lancet i, 292.CrossRefGoogle Scholar
Lowbury, E. J. L & Fox, J. E. (1954). The epidemiology of infection with Pseudomonas pyocyanea in a burns unit. Journal of Hygiene 52, 403.CrossRefGoogle Scholar
Lowbury, E. J. L, Thom, B. T., Lilly, H. A., Babb, J. R. & Whittall, (1970). Sources of infection with Pseudomonas aeruginosa in patients with tracheostomy. Journal of Medical Microbiology 3, 39.Google Scholar
Reyniers, J. A. & Trexler, P. C. (1943). The germfree technique and its application to rearing animals free from contamination, in Micrurgical and Germfree Techniques, p. 114, ed. Reyniers, J. A.. Springfield: C. C. Thomas.Google Scholar
Topley, E., Lowbury, E. J. L & Hurst, L. (1951). Bacteriological control of aureomycin therapy. Lancet i, 87.CrossRefGoogle Scholar
United States Public Health Service (1970). Isolation Techniques for Use in Hospitals. Washington: U.S. Government Printing Office.Google Scholar