Hostname: page-component-cd9895bd7-gbm5v Total loading time: 0 Render date: 2024-12-22T15:54:22.188Z Has data issue: false hasContentIssue false

A micro immune haemolysis test for rubella antibody screening

Published online by Cambridge University Press:  19 October 2009

H. G. S. Murray
Affiliation:
Division of Microbiological Reagents and Quality Control, 175 Colindale Avenue, London NW9 5HT
Rights & Permissions [Opens in a new window]

Summary

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

A micro test for the detection of rubella IgG antibody by passive haemolysis in free solution (MIH) is presented. The technique is reproducible, sensitive, simple to perform and economical in the use of reagents. Identical results were obtained in all but one of 408 tests on serum specimens screened for rubella antibody at 15 i.u./ml by the MIH and haemagglutination inhibition (HI) techniques. The quantitative potential of the MIH test and the relative merits of the MIH, HI and radial haemolysis (RH) procedures for rubella screening are discussed.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1984

References

REFERENCES

Forger, J. M. III & Gilfillan, R. F. (1979). Single-radial hemolysis as a cost-effective determinant of rubella antibody status. Journal of Clinical Microbiology 9, (1), 115119.CrossRefGoogle ScholarPubMed
Mortimer, P. P., Edwards, J. M. B., Porter, A. D., Tedder, R. S., Made, J. E. & Hutchinson, A.(1981). Are many women immunized against rubella unnecessarily? Journal of Hygiene 87, 131138.CrossRefGoogle ScholarPubMed
Norrby, E. (1962). Haemagglutination by measles virus. 4. A simple procedure for production of high potency antigen for haemagglutination inhibition (HI) tests. Proceedings of the Society for Experimental Biology and Medicine 111, 814818.CrossRefGoogle ScholarPubMed
Pattison, J. R. (1982). Rubella antibody screening. Journal of Hygiene 88, 140153.CrossRefGoogle ScholarPubMed
Schild, G. C., Pereira, M. S. & Chakraverty, P. (1975). Single radial-haemolysis. A new method for the assay of antibody to influenza haemagglutinin. Bulletin of the World Health Organization 52, 4350.Google ScholarPubMed
Skauo, K., Orstavik, I. & Ulstrup, J. C. (1975). Application of the passive haemolysis test for the determination of rubella virus antibodies. Acta Pathologica et Microbiologica Scandinavica B 83, 367372.Google Scholar
Stranneoard, O., Grillner, L. & Lindbero, I.-M. (1975). Hemolysis-in-gel test for the demonstration of antibodies to rubella virus. journal of Clinical Microbiology 1 (6), 491494.CrossRefGoogle Scholar
Report, . (1978). Haemagglutination-inhibition test for the detection of rubella antibody. Journal of Hygiene 81, 373382.Google Scholar