Hostname: page-component-586b7cd67f-2brh9 Total loading time: 0 Render date: 2024-11-29T07:59:45.900Z Has data issue: false hasContentIssue false

Detection of tetanus toxoid antibodies in human sera in New Zealand by ELISA

Published online by Cambridge University Press:  19 October 2009

R. C. H. Lau
Affiliation:
Immunology Research and Development Unit, National Health Institute, Kenepuru Drive, Porirua, Wellington, New Zealand
Rights & Permissions [Opens in a new window]

Summary

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

An enzyme-linked immunosorbent assay (ELISA) incorporating the sensitive biotin-streptavidin system was developed to detect IgG antibodies to tetanus toxoid in human serum. Serum samples obtained from 557 normal persons aged 1–65 years from different areas in New Zealand were tested. The proportion of those immune ranged from 60–93% in males, and from 46–86% in females. In the 1–9 years age group 85% were immune. The indirect ELISA is suitable for serological surveys as it is simple to perform, economical and reproducible.

Type
Research Article
Copyright
Copyright © Cambridge University Press 1987

References

REFERENCES

Barile, M. F., Hardegree, M. C. & Pittman, M. (1970). Immunization against neonatal tetanus in New Guinea. 3. The toxin-neutralization test and the response of guinea-pigs to the toxoids as used in the immunization schedules in New Guinea. Bulletin of World Health Organization 43, 453459.Google Scholar
Booth, J. R. & Nuttal, P. A. (1978). A rapid automated latex screen for tetanus toxoid antibodies. Vox Sanguinis 34, 239240.CrossRefGoogle ScholarPubMed
Campbell Begg, R. (1984). Pertussis – New Zealand 1982/83. New Zealand Medical Journal 97, 408411.Google Scholar
Habermann, E., Howath, E. & Schaeg, W. (1977). A radioimmunoassay for tetanus antibodies using Protein A-containing Staphylococcus aureus. Medical Microbiology and Immunology 163, 261268.CrossRefGoogle ScholarPubMed
Melville-Smith, M. E., Seagroatt, V. A. & Watkins, J. T. (1983). A comparison of enzyme-linked immunosorbent assay (ELISA) with the toxin neutralization test in mice as a method for the estimation of tetanus antitoxin in human sera. Journal of Biological Standardization 11, 137144.CrossRefGoogle ScholarPubMed
New Zealand Department of Health, Annual Report 1969.Google Scholar
New Zealand Official Yearbook, 1981.Google Scholar
Sedgwick, A. K., Ballow, M., Sparks, K. & Tilton, R. C. (1983). Rapid quantitative microenzyme-linked immunosorbent assay for tetanus antibodies. Journal of Clinical Microbiology 18, 104109.CrossRefGoogle ScholarPubMed
World Health Organization, Weekly Epidemiological Record (1986) 43, 101102.Google Scholar