Hostname: page-component-78c5997874-t5tsf Total loading time: 0 Render date: 2024-11-17T16:54:10.973Z Has data issue: false hasContentIssue false

Total anomalous pulmonary venous connection in a neonate characterised by low-dose, high-pitch cardiac CT

Published online by Cambridge University Press:  24 July 2014

Swati Deshmukh
Affiliation:
The Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland, United States of America
W. Reid Thompson
Affiliation:
Department of Pediatrics, Johns Hopkins Medical Institutions, Baltimore, Maryland, United States of America
Stefan L. Zimmerman*
Affiliation:
The Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University School of Medicine, Baltimore, Maryland, United States of America
*
Correspondence to: S. L. Zimmerman, MD, The Russell H. Morgan Department of Radiology and Radiological Sciences, Johns Hopkins University School of Medicine, 601N. Caroline Street, JHOC 3142, Box 0818, Baltimore, MD 21287, United States of America. Tel: 410 955 8450; Fax: 410 614 9865; E-mail: [email protected]

Abstract

We describe the use of low-dose dual-source cardiac for the evaluation of a neonate with suspected total anomalous pulmonary venous connection. This novel technique obviates the need for sedation or breathholding. Radiation dose-reduction strategies result in sub-mSv-estimated effective doses, substantially lower than annual background radiation dose. Low-dose, high-pitch cardiac CT should be considered as an alternative to MRI or diagnostic cardiac catheterisation in neonates with complex CHD, requiring definitive anatomic evaluation.

Type
Brief Reports
Copyright
© Cambridge University Press 2014 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Dougeni, E, Faulkner, K, Panayiotakis, G. A review of patient dose and optimisation methods in adult and paediatric CT scanning. Eur J Radiol 2012; 81: e665e683.Google Scholar
2. Bacher, K, Bogaert, E, Lapere, R, De Wolf, D, Thierens, H. Patient-specific dose and radiation risk estimation in pediatric cardiac catheterization. Circulation 2005; 111: 8389.Google Scholar
3. Han, BK, Grant, KL, Garberich, R, Sedlmair, M, Lindberg, J, Lesser, JR. Assessment of an iterative reconstruction algorithm (SAFIRE) on image quality in pediatric cardiac CT datasets. J Cardiovasc Comput Tomogr 2012; 6: 200204.Google Scholar
4. Lell, MM, May, M, Deak, P, et al. High-pitch spiral computed tomography: effect on image quality and radiation dose in pediatric chest computed tomography. Invest Radiol 2011; 46: 116123.Google Scholar
5. Han, BK, Overman, DM, Grant, K, et al. Non-sedated, free breathing cardiac CT for evaluation of complex congenital heart disease in neonates. J Cardiovasc Comput Tomogr 2013; 7: 354360.Google Scholar