Hostname: page-component-745bb68f8f-g4j75 Total loading time: 0 Render date: 2025-01-22T12:56:37.931Z Has data issue: false hasContentIssue false

Percutaneous self-expandable valve implantation in patients with stented pulmonary arteries: case examples

Published online by Cambridge University Press:  17 January 2025

Judyta Szeliga
Affiliation:
Department of Paediatric Cardiology, University Children’s Hospital, Jagiellonian University Medical College, Krakow, Poland
Marc Gewillig
Affiliation:
Department Pediatric Cardiology, University Hospitals Leuven, Leuven, Belgium
Sebastian Góreczny*
Affiliation:
Department of Paediatric Cardiology, University Children’s Hospital, Jagiellonian University Medical College, Krakow, Poland
*
Corresponding author: Sebastian Góreczny; Email: [email protected]

Abstract

CHDs affecting the right ventricular outflow tract often require repeated surgical or transcatheter interventions due to pulmonary insufficiency or stenosis. This study presents percutaneous implantation of large self-expanding valves in patients with complex right ventricular outflow tract anatomy after prior pulmonary branch stenting.

Type
Brief Report
Copyright
© The Author(s), 2025. Published by Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Fiszer, R, Dryżek, P, Szkutnik, M et al. Immediate and long-term outcomes of percutaneous transcatheter pulmonary valve implantation. Cardiol J 2017; 24: 604611.CrossRefGoogle ScholarPubMed
Promphan, W, Prachasilchai, P, Siripornpitak, S, Qureshi, SA, Layangool, T. Percutaneous pulmonary valve implantation with the Venus P-valve: clinical experience and early results. Cardiol Young 2016; 26: 698710.CrossRefGoogle ScholarPubMed
Husain, J, Praichasilchai, P, Gilbert, Y, Qureshi, SA, Morgan, GJ. Early European experience with the Venus P-valve®: filling the gap in percutaneous pulmonary valve implantation. EuroIntervention 2016; 12: e643e651.CrossRefGoogle Scholar
Garay, F, Pan, X, Zhang, YJ, Wang, C, Springmuller, D. Early experience with the Venus p-valve for percutaneous pulmonary valve implantation in native outflow tract. -valve for percutaneous pulmonary valve implantation in native outflow tract. Neth Heart J 2017; 25: 7681.CrossRefGoogle ScholarPubMed
Morgan, GJ, Sivakumar, K, Promphan, W, Goreczny, S, Prachasilchai, P, Qureshi, S. Early clinical experience with the straight design of Venus P-valveTM in dysfunctional right ventricular outflow tracts. Catheter Cardiovasc Interv 2020; 96: E653E659.CrossRefGoogle Scholar
Morgan, G, Prachasilchai, P, Promphan, W et al. Medium-term results of percutaneous pulmonary valve implantation using the Venus P-valve: international experience. EuroIntervention 2019; 14: 13631370.CrossRefGoogle ScholarPubMed
Sivakumar, K, Sagar, P, Qureshi, S et al. Outcomes of Venus P-valve for dysfunctional right ventricular outflow tracts from Indian Venus P-valve database. Ann Pediatr Cardiol 2021; 14: 281292.CrossRefGoogle ScholarPubMed
Góreczny, S, Szeliga, J, Lazu, M, Załuska-Pitak, B, Gewillig, M. First Polish pediatric experience with percutaneous self-expandable pulmonary valve implantation. Kardiol Pol 2024; 82: 101102.CrossRefGoogle ScholarPubMed
Góreczny, S, Szeliga, J, Lazu, M, Becht, R, Mroczek, T, Qureshi, S. Implantation of a large self-expanding pulmonary valve using the jugular vein approach in a teenage patient. Kardiol Pol 2024; 82: 549550.CrossRefGoogle Scholar
Goreczny, S, Moszura, T, Dryzek, P et al. Three-dimensional image fusion guidance of percutaneous pulmonary valve implantation to reduce radiation exposure and contrast dose: A comparison with traditional two-dimensional and three-dimensional rotational angiographic guidance. Neth Heart J 2017; 25: 9199.CrossRefGoogle Scholar
Supplementary material: File

Szeliga et al. supplementary material 1

Szeliga et al. supplementary material
Download Szeliga et al. supplementary material 1(File)
File 16.7 MB
Supplementary material: File

Szeliga et al. supplementary material 2

Szeliga et al. supplementary material
Download Szeliga et al. supplementary material 2(File)
File 25.1 MB