Hostname: page-component-cd9895bd7-jn8rn Total loading time: 0 Render date: 2024-12-24T16:07:45.533Z Has data issue: false hasContentIssue false

Not just another large atrial septal defect: complex anatomy, challenging procedure, and an unusual complication

Published online by Cambridge University Press:  16 June 2020

Raymond N. Haddad*
Affiliation:
Hotel Dieu de France University Medical Center, Department of Pediatrics, Saint Joseph University, Beirut, Lebanon
Tony Abdel Massih
Affiliation:
Hotel Dieu de France University Medical Center, Department of Cardiology, Saint Joseph University, Beirut, Lebanon
Zakhia Saliba
Affiliation:
Hotel Dieu de France University Medical Center, Department of Pediatric Cardiology, Saint Joseph University, Beirut, Lebanon
*
Author for correspondence: Dr. Raymond N. Haddad, MD, Department of Pediatrics, Hotel Dieu de France University Medical Center, Saint Joseph University, Alfred Naccache Boulevard, Achrafieh, Beirut, Lebanon BP. Tel: +33 7 53 15 95 04; +961 70 605 800; Fax: +961 1 604 976. E-mail: [email protected]

Abstract

We report the case of a 59-year-old patient with a complex atrial septal defect in whom a 40-mm Amplatzer™ septal occluder was surgically extracted 50 days following implantation. Deployment manoeuvres were challenging leading to an immediate pericardial effusion that was closely monitored and uneventfully drained after 11 days. A dry pericardium was documented until 4 weeks of outpatient routine follow-up. However, the device was surgically explanted 2 weeks later, when an urgent chest computed tomography performed for worrisome symptoms showed pericardial effusion recurrence with peripheral contrast enhancement. Surprisingly, the surgical view showed a well-positioned device and an intact pericardium. We discuss the atypical sequence of clinical findings misleading our clinical judgement and precipitating surgery.

Type
Brief Report
Copyright
© The Author(s), 2020. Published by Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Butera, G, Biondi-Zoccai, G, Sangiorgi, G, et al.Percutaneous versus surgical closure of secundum atrial septal defects: a systematic review and meta-analysis of currently available clinical evidence. EuroIntervention 2011; 7: 377385.CrossRefGoogle ScholarPubMed
Crawford, GB, Brindis, RG, Krucoff, MW, et al.Percutaneous atrial septal occluder devices and cardiac erosion: a review of the literature. Catheter Cardiovasc Interv 2012; 80: 157167.CrossRefGoogle ScholarPubMed
Sauer, HH, Ntalakoura, K, Haun, C, et al.Early cardiac perforation after atrial septal defect closure with the Amplatzer septal occluder. Ann Thorac Surg 2006; 81: 23122313.CrossRefGoogle ScholarPubMed
Roberts, WT, Parmar, J, Rajathurai, T.Very late erosion of Amplatzer septal occluder device presenting as pericardial pain and effusion 8 years after placement. Cathe Cardiovasc Interv 2013; 82: 592–584.Google ScholarPubMed
Mendirichaga, R, Smairat, R, Sancassani, R.Late tissue erosion after transcatheter closure of an atrial septal defect. Catheter Cardiovasc Interv 2017; 89: 502504.CrossRefGoogle ScholarPubMed
Amin, Z, Hijazi, ZM, Bass, JL, et al.Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk. Catheter Cardiovasc Interv 2004; 63: 496502.CrossRefGoogle ScholarPubMed
Moore, J, Hegde, S, El-Said, H, et al.Transcatheter device closure of atrial septal defects: a safety review. JACC Cardiovasc Interv 2013; 6: 433442.CrossRefGoogle ScholarPubMed
Carroll, JD.Device erosion. Catheter Cardiovasc Interv 2009; 73: 931932.CrossRefGoogle ScholarPubMed
Amin, Z.Echocardiographic predictors of cardiac erosion after Amplatzer septal occluder placement. Catheter Cardiovasc Interv 2014; 83: 8492.CrossRefGoogle ScholarPubMed
Divekar, A, Gaamangwe, T, Shaikh, N, et al.Cardiac perforation after device closure of atrial septal defects with the Amplatzer septal occluder. J Am Coll Cardiol 2005; 45: 12131218.CrossRefGoogle ScholarPubMed