Lessons learned with the use of CentriMag as short-term ventricular assist device in a child

Published online by Cambridge University Press:  07 July 2014

Thittamaranahalli Kariyappa S. Kumar*
Affiliation:
Department of Pediatric Cardiothoracic Surgery, Le Bonheur Children’s Hospital, University of Tennessee, Memphis, Tennessee, United States of America
Jean Ballweg
Affiliation:
Department of Pediatric Cardiology, Le Bonheur Children’s Hospital, University of Tennessee, Memphis, Tennessee, United States of America
Christopher J. Knott-Craig
Affiliation:
Department of Pediatric Cardiothoracic Surgery, Le Bonheur Children’s Hospital, University of Tennessee, Memphis, Tennessee, United States of America
*
Correspondence to: T. K. Susheel Kumar, MD, Assistant Professor, Department of Pediatric Cardiothoracic Surgery, Le Bonheur Children’s Hospital, University of Tennessee, 50 N Dunlap Street, Memphis, TN 38103, United States of America. Tel: +901 287 5995; Fax: +901 287 5970; E-mail: [email protected]

Abstract

The CentriMag ventricular assist device is an extracorporeal, third-generation, continuous flow device. The rapidity and simplicity of operation along with low priming volume make it attractive for use in children with refractory heart failure. We report the successful use of CentriMag as a bridge to recovery in a child and discuss issues that are unique to its use in children.

Type
Brief Reports
Copyright
© Cambridge University Press 2014 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. John, R, Liao, K, Lietz, K, et al. Experience with the Levitronix CentriMag circulatory support system as a bridge to decision in patients with refractory acute cardiogenic shock and multisystem organ failure. J Thorac Cardiovasc Surg 2007; 134: 351358.Google Scholar
2. De Robertis, F, Rogers, P, Amrani, M, et al. Bridge to decision using the Levitronix CentriMag short-term ventricular assist device. J Heart Lung Transplant 2008; 27: 474478.Google Scholar
3. Shuhaiber, JH, Jenkins, D, Berman, M, et al. The Papworth experience with the Levitronix CentriMag ventricular assist device. J Heart Lung Transplant 2008; 27: 158164.CrossRefGoogle ScholarPubMed
4. Hirata, Y, Charette, K, Mosca, RS, Quaegebeur, JM, Chen, JM. Pediatric application of the Thoratec CentriMag BiVAD as a bridge to heart transplantation. J Thorac Cardiovasc Surg 2008; 136: 13861387.Google Scholar
5. Maat, AP, van Thiel, RJ, Dalinghaus, M, Bogers, AJ. Connecting the Centrimag Levitronix pump to Berlin Heart Excor cannulae; a new approach to bridge to bridge. J Heart Lung Transplant 2008; 27: 112115.Google Scholar
6. Loforte, A, Potapov, E, Krabatsch, T, et al. Levitronix CentriMag to Berlin Heart Excor: a “bridge to bridge” solution in refractory cardiogenic shock. ASAIO J 2009; 55: 465468.CrossRefGoogle ScholarPubMed
7. Takayama, H, Chen, JM, Jorde, UP, Naka, Y. Implantation technique of the CentriMag biventricular assist device allowing ambulatory rehabilitation. Interact Cardiovasc Thorac Surg 2011; 12: 110111.Google Scholar
8. Slaughter, MS, Pagani, FD, Rogers, JG, et al. Clinical management of continuous-flow left ventricular assist devices in advanced heart failure. J Heart Lung Transplant 2010; 29: S1S39.Google Scholar