Hostname: page-component-cd9895bd7-hc48f Total loading time: 0 Render date: 2024-12-27T03:38:39.540Z Has data issue: false hasContentIssue false

Comprehensive four-dimensional phase-contrast flow assessment in hemi-Fontan circulation: systemic-to-pulmonary collateral flow quantification

Published online by Cambridge University Press:  27 October 2010

Israel Valverde*
Affiliation:
Division of Imaging Sciences, King’s College London, London, United Kingdom Department of Pediatric Cardiology, Evelina Children Hospital, Guy’s and St Thomas’ NHS Foundation Trust, London, United Kingdom
Clough Rachel
Affiliation:
Division of Imaging Sciences, King’s College London, London, United Kingdom
Titus Kuehne
Affiliation:
Unit of cardiovascular Imaging, Department of Paediatric Cardiology, German Heart Institute Berlin, Berlin, Germany
Philipp Beerbaum
Affiliation:
Division of Imaging Sciences, King’s College London, London, United Kingdom Department of Pediatric Cardiology, Evelina Children Hospital, Guy’s and St Thomas’ NHS Foundation Trust, London, United Kingdom
*
Correspondence to: Dr I. Valverde, Division of Imaging Sciences, King’s College London, The Rayne Institute, 4th Floor, Lambeth Wing, St Thomas Hospital, London SE1 7EH, United Kingdom. Tel: +44 (0) 2071888385; Fax: +44 (0) 2071885442; E-mail: [email protected]

Abstract

Precise lung perfusion quantification is essential for evaluation of patients with hemi-Fontan surgery. It is possible for two-dimensional cardiac magnetic resonance phase contrast flow (two-dimensional flow) to evaluate non-invasively the systemic-to-pulmonary collateral blood flow. This case report intends to illustrate the benefit of four-dimensional flow over the current two-dimensional flow in the comprehensive assessment of hemi-Fontan patients.

Type
Brief Reports
Copyright
Copyright © Cambridge University Press 2010

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Castaneda, AR. From Glenn to Fontan. A continuing evolution. Circulation 1992; 86: II80II84.Google Scholar
2. Beerbaum, P, Korperich, H, Barth, P, Esdorn, H, Gieseke, J, Meyer, H. Noninvasive quantification of left-to-right shunt in pediatric patients: phase-contrast cine magnetic resonance imaging compared with invasive oximetry. Circulation 2001; 103: 24762482.CrossRefGoogle ScholarPubMed
3. Wigstrom, L, Ebbers, T, Fyrenius, A, et al. Particle trace visualization of intracardiac flow using time-resolved 3D phase contrast MRI. Magn Reson Med 1999; 41: 793799.3.0.CO;2-2>CrossRefGoogle ScholarPubMed
4. Napel, S, Lee, DH, Frayne, R, Rutt, BK. Visualizing three-dimensional flow with simulated streamlines and three-dimensional phase-contrast MR imaging. J Magn Reson Imaging 1992; 2: 143153.CrossRefGoogle ScholarPubMed
5. Hope, MD, Meadows, AK, Hope, TA, et al. Clinical evaluation of aortic coarctation with 4D flow MR imaging. J Magn Reson Imaging 2010; 31: 711718.CrossRefGoogle ScholarPubMed
6. Grosse-Wortmann, L, Al-Otay, A, Yoo, SJ. Aortopulmonary collaterals after bidirectional cavopulmonary connection or Fontan completion: quantification with MRI. Circ Cardiovasc Imaging 2009; 2: 219225.CrossRefGoogle ScholarPubMed
7. Whitehead, KK, Gillespie, MJ, Harris, MA, Fogel, MA, Rome, JJ. Noninvasive quantification of systemic-to-pulmonary collateral flow: a major source of inefficiency in patients with superior cavopulmonary connections. Circ Cardiovasc Imaging 2009; 2: 405411.CrossRefGoogle Scholar
8. Nordmeyer, S, Riesenkampff, E, Crelier, G, Khasheei, A, Kuehne, T. Flow-sensitive four-dimensional magnetic resonance imaging for offline blood flow quantification in multiple vessels. J Cardiovasc Magn Reson 2010.Google ScholarPubMed
9. Sorensen, TS, Beerbaum, P, Korperich, H, Pedersen, EM. Three-dimensional, isotropic MRI: a unified approach to quantification and visualization in congenital heart disease. Int J Cardiovasc Imaging 2005; 21: 283292.CrossRefGoogle ScholarPubMed
10. Uribe, S, Beerbaum, P, Sorensen, TS, Rasmusson, A, Razavi, R, Schaeffter, T. Four-dimensional (4D) flow of the whole heart and great vessels using real-time respiratory self-gating. Magn Reson Med 2009; 62: 984992.CrossRefGoogle ScholarPubMed

Valverde supplementary material

Movie 1.mov

Download Valverde supplementary material(Video)
Video 4.6 MB

Valverde supplementary material

Movie 2.mov

Download Valverde supplementary material(Video)
Video 4.1 MB

Valverde supplementary material

Movie 3.mov

Download Valverde supplementary material(Video)
Video 5.1 MB

Valverde supplementary material

Movie 4.mov

Download Valverde supplementary material(Video)
Video 4.5 MB