Congenital pulmonary valve stenosis is a relatively common congenital heart malformation that accounts between 7,5 and 9% of all congenital heart malformations. The first-line treatment widely accepted is percutaneous balloon valvotomy. Reference Balushi, Shuaili, Khabori and Maskri1
Case presentation
We report a case of a 9-year-old male known with a history of genetical disorder (translocation [4;21] [q27;q22]), who was referred to our centre for severe congenital pulmonary valve stenosis. On admission, the trans-thoracic echocardiogram confirmed the pulmonary valve stenosis with a peak/mean pulmonary valve gradient of 91/53 mmHg and a pulmonary annulus of 13.8 mm (−0.8 ZScore) and also showed dilated right chambers with a RV/LV ratio of 0,9 He underwent cardiac catheterisation for a planned pulmonary valve balloon dilation. During the procedure, the additional presence of a secundum atrial septal defect was acknowledged. The anatomic features of the atrial septal defect would not allow an endovascular device placement. As there was a surgical indication for atrial septal defect closure (Qp/Qs > 2), the pulmonary valve dilation procedure was not performed. The patient was scheduled for surgery. Preoperative transesophageal echocardiogram confirmed severe pulmonary valve stenosis. The presence of a dysplastic bicuspid pulmonary valve was described (Fig. 1a–c).
After going on cardiopulmonary bypass, the atrial septal defect was directly by a running suture. Through a transverse pulmonary arteriotomy, exploration of the pulmonary valve revealed a typical unicuspid valve. Only the right commissure was well developed while the height of the left raphe was reduced (Fig. 2, black circle, asterisk). The pulmonary valve repair consisted in a bicuspidisation (orientation: 180 degrees) by a large commissurotomy to the anterior wall of the pulmonary artery, extending slightly into the annular plane (Fig. 3a). Partial disinsertion of the leaflet along the annular plane of the two newly created leaflets allowed to adjust the effective height of the native leaflets. The neo-commissure was created with two separate patches of autologous pericardium secured to the wall of the pulmonary root. The patches were trimmed to fit the leaflet defects secondary to the disinsertion of part of the native valve from the annulus (Fig. 3b,c). Final adjustment of the effective height of the newly created leaflets was done by triangular plication of the posterior leaflet (Fig. 3d). The final result was a newly created bicuspid valve with a butterfly patch (Fig. 3e, white circular shape). The total cross-clamp and bypass time were 92 and 123 min, respectively. Perioperative echocardiogram showed a peak gradient of 15 mm Hg and trivial pulmonary regurgitation (Video 1). The patient made an uneventful recovery and was discharged on day 8.
Discussion
Unicuspid pulmonary valves are extremely rare, in the absence of complex CHD. Reference Burrage, Baker, Nikolaidou, Myerson and Ferreira2 There is evidence for relief of pulmonary valve obstruction immediately after balloon pulmonary valvotomy and at follow-up. Reference Rao3 In our case, the percutaneous treatment was not the ideal option as the unexpected associated diagnosis of multifenestrated secundum atrial septal defect could not be treated percutaneously. The experience in bicuspidisation of unicuspid stenotic pulmonary valves is scarce, and as far as we know, there are no published case reports delineating a surgical approach for the repair of such pulmonary valve. The bicuspidisation technique was primarily developed for the unicommissural unicuspid aortic valves, also a very rare congenital malformation[Reference Schäfers, Aicher and Riodionycheva4,Reference Gofus, Karalko and Fila5] . Though the fresh autologous pericardium usually demonstrated thickening with retraction, Reference Schwartzman, Jimenez and Yates6 there is evidence in the literature that in pulmonary position, it remains supple, non-calcified and is able to reduce the pulmonary regurgitation and maintain normal function of right ventricle at long term. Reference Pande, Arya and Agarwal7 Furthermore, it has also presented the capability to increase in length and consequently, the neo pulmonary valve can grow to meet the demand of the growing child. This was the rationale for using fresh pericardium patch for leaflet augmentation in our case. The main goals of our surgical approach were (a) to obtain a reduction of peak systolic pressure gradients across the pulmonary valve, below 25 ± 19 mmHg (15 mmHg) Reference Rao3 and (b) a better coaptation surface, which could theoretically lead to improved long-term results compared to interventional balloon valvotomy. Indeed, the percutaneous treatment presents a high percentage of pulmonary regurgitation and right ventricle dilation at long-term follow-up. Reference Merino-Ingelmo, Soto, Coserria-Sánchez, Descalzo-Señoran and Valverde-Pérez8
Conclusion
The evidence for bicuspidisation of unicuspid stenotic pulmonary valves in the literature is scarce. Based on the experience with unicuspid aortic valve repair which is growing, the surgical steps to bicuspidise a unicuspid pulmonary valve can be adapted, while requiring a broad surgical expertise in valve repairs. Detailed preoperative planning and a tailored approach for every patient are mandatory in order to achieve a good repair result.