Hostname: page-component-78c5997874-t5tsf Total loading time: 0 Render date: 2024-11-19T10:13:57.712Z Has data issue: false hasContentIssue false

Impact of the superior cavopulmonary anastomosis on cerebral oxygenation

Published online by Cambridge University Press:  16 March 2020

Nikhil Thatte
Affiliation:
Department of Cardiology, Boston Children’s Hospital, Boston, MA, USA Department of Pediatrics, Harvard Medical School, Boston, MA, USA
Lingyu Zhou
Affiliation:
Department of Cardiology, Boston Children’s Hospital, Boston, MA, USA Department of Pediatrics, Harvard Medical School, Boston, MA, USA
John N. Kheir*
Affiliation:
Department of Cardiology, Boston Children’s Hospital, Boston, MA, USA Department of Pediatrics, Harvard Medical School, Boston, MA, USA
*
Author for correspondence: J. N. Kheir, MD, Department of Cardiology, Boston Children’s Hospital 300 Longwood Avenue, Boston, MA02115, USA. Tel: +1 857-636-8890; Fax: +617-730-0009. E-mail: [email protected]

Abstract

Background:

Patients with univentricular heart disease may undergo a superior cavopulmonary anastomosis, an operative intervention that raises cerebral venous pressure and impedance to cerebral venous return. The ability of infantile cerebral autoregulation to compensate for this is not well understood.

Materials and methods:

We identified all patients undergoing a superior cavopulmonary anastomosis (cases) and compared metrics of cerebral oxygenation upon admission to the ICU with patients following repair of tetralogy of Fallot or arterial switch operation (controls). The primary endpoint was cerebral venous oxyhaemoglobin saturation measured from an internal jugular venous catheter. Other predictor variables included case–control assignment, age, weight, sex, ischemic times, arterial oxyhaemoglobin saturation, mean arterial blood pressure, and superior caval pressure.

Results:

A total of 151 cases and 350 controls were identified. The first post-operative cerebral venous oxyhaemoglobin saturation was significantly lower following superior cavopulmonary anastomosis than in controls (44 ± 12 versus 59 ± 15%, p < 0.001), as was arterial oxyhaemoglobin saturation (81 ± 9 versus 98 ± 5%, p < 0.001). Cerebral venous oxyhaemoglobin saturation correlated poorly with superior caval pressure in both groups. When estimated by linear mixed effects model, arterial oxyhaemoglobin saturation was the primary determinant of central venous oxyhaemoglobin saturation in both groups (β = 0.79, p = 3 × 10−14); for every 1% point increase in arterial oxyhaemoglobin saturation, there was a 0.79% point increase in venous oxyhaemoglobin saturation. In this model, no other predictors were significant, including superior caval pressure and case–control assignment.

Conclusion:

Cerebral autoregulation appears to remain intact despite acute imposition of cerebral venous hypertension following superior cavopulmonary anastomosis. Following superior cavopulmonary anastomosis, cerebral venous oxyhaemoglobin saturation is primarily determined by arterial oxyhaemoglobin saturation.

Type
Brief Report
Copyright
© The Author(s), 2020. Published by Cambridge University Press

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Yagi, Y, Yamamoto, M, Saito, H, et al.Changes of cerebral oxygenation in sequential Glenn and Fontan procedures in the same children. Pediatr Cardiol 2017; 38: 12151219. doi: 10.1007/s00246-017-1647-0.CrossRefGoogle ScholarPubMed
Bertolizio, G, Dinardo, JA, Laussen, PC, et al.Evaluation of cerebral oxygenation and perfusion with conversion from an arterial-to-systemic shunt circulation to the bidirectional Glenn circulation in patients with univentricular cardiac abnormalities. J Cardiothorac Vasc Anesth. 2015; 29: 95100. doi: 10.1053/j.jvca.2014.06.001.CrossRefGoogle ScholarPubMed
Rescoe, E, Tang, X, Perry, DA, et al.Cerebral near-infrared spectroscopy insensitively detects low cerebral venous oxygen saturations after stage 1 palliation. J Thorac Cardiovasc Surg 2017; 154: 10561062. doi: 10.1016/j.jtcvs.2017.03.154.CrossRefGoogle ScholarPubMed
Gagnon, MH, Kussman, BD, Zhou, L, et al.Sensitivity of a next-generation NIRS device to detect low mixed venous oxyhemoglobin saturations in the single ventricle population. Anesth Analges 2020. doi: 10.1213/ANE.0000000000004580.CrossRefGoogle ScholarPubMed
Nishizawa, H, Kudoh, I.Cerebral autoregulation is impaired in patients resuscitated after cardiac arrest. Acta Anaesthesiol Scand 1996; 40: 11491153.CrossRefGoogle ScholarPubMed
Slupe, AM, Kirsch, JR.Effects of anesthesia on cerebral blood flow, metabolism, and neuroprotection. J Cereb Blood Flow Metab 2018; 38: 21922208. doi: 10.1177/0271678X18789273. Epub 2018 Jul 16.CrossRefGoogle ScholarPubMed