Hostname: page-component-586b7cd67f-t7czq Total loading time: 0 Render date: 2024-11-25T07:12:34.749Z Has data issue: false hasContentIssue false

Motor Unit Number Index of the Upper Trapezius: A Meta-Analysis and Cross-sectional Study of Its Reliability

Published online by Cambridge University Press:  08 February 2023

Agessandro Abrahao*
Affiliation:
Division of Neurology, Department of Medicine, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada Sunnybrook Research Institute, University of Toronto, Toronto, Ontario, Canada
Liane Phung
Affiliation:
Sunnybrook Research Institute, University of Toronto, Toronto, Ontario, Canada
David Fam
Affiliation:
St. Joseph’s Health Centre Toronto, United Health, Toronto, Ontario, Canada
Marcio Luiz Escorcio-Bezerra
Affiliation:
Department of Neurology and Neurosurgery, Universidade Federal de São Paulo, São Paulo, Brazil
Lawrence R. Robinson
Affiliation:
Division of Physical Medicine and Rehabilitation, Department of Medicine, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
Kelvin E. Jones
Affiliation:
Faculty of Kinesiology, Sport and Recreation, University of Alberta, Edmonton, Alberta, Canada
Lorne Zinman
Affiliation:
Division of Neurology, Department of Medicine, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada Sunnybrook Research Institute, University of Toronto, Toronto, Ontario, Canada
*
Corresponding author: Agessandro Abrahao, MD MSc, Sunnybrook Health Sciences Centre, University of Toronto, 2075 Bayview Avenue, H wing, Room H4-34, Toronto, Ontario M4N 3M5, Canada. Email: [email protected]
Rights & Permissions [Opens in a new window]

Abstract:

Motor unit number index of the upper trapezius (MUNIX-Trapezius) is a candidate biomarker for bulbar lower motor neuron function; however, reliability data is incomplete. To assess MUNIX-Trapezius reliability in controls, we conducted a systematic review, a cross-sectional study (n = 20), and a meta-analysis. We demonstrated a high inter- and intra-rater intraclass correlation (0.86 and 0.94, respectively), indicating that MUNIX-Trapezius is reliable with between-study variability moderated by age and MUNIX technique. With further validation, this measure can serve as a disease monitoring and response biomarker of bulbar function in the therapeutic development for amyotrophic lateral sclerosis.

Résumé :

RÉSUMÉ :

Estimer le nombre d’unités motrices du faisceau supérieur du muscle trapèze : une méta-analyse et une étude transversale de la fiabilité de ce biomarqueur.

L’indice du nombre d’unités motrices du faisceau supérieur du muscle trapèze (motor unit number index of the upper trapezius) est un biomarqueur candidat en ce qui regarde la fonction des motoneurones inférieurs de la région bulbaire. Cela dit, les données sur sa fiabilité demeurent incomplètes. Pour l’évaluer chez des témoins, nous avons réalisé une revue systématique, une étude transversale (n = 20) ainsi qu’une méta-analyse. Nous avons pu démontrer ainsi une forte corrélation intra-classe inter et intra-évaluateur (respectivement 0,86 et 0,94), ce qui indique que ce biomarqueur est fiable avec une variabilité inter-étude modérée par son utilisation et l’âge. Avec une validation plus poussée, l’indice du nombre d’unités motrices du faisceau supérieur du muscle trapèze peut permettre le suivi de la sclérose latérale amyotrophique (SLA) et de la réponse de la fonction bulbaire dans le développement thérapeutique destiné à cette maladie.

Type
Brief Communication
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution and reproduction, provided the original article is properly cited.
Copyright
© The Author(s), 2023. Published by Cambridge University Press on behalf of Canadian Neurological Sciences Federation

Introduction

Motor unit number index (MUNIX) is a neurophysiological technique that indirectly estimates the number of functioning motor units of a given muscle. Calculated by modeling the compound motor action potential (CMAP) and surface interference pattern (SIP), Reference Nandedkar, Nandedkar, Barkhaus and Stalberg1 MUNIX correlates with other motor unit number estimation (MUNE) methods with excellent reliability in limb muscles. Reference Fatehi, Grapperon, Fathi, Delmont and Attarian2 The technique can be employed as an outcome measure for multicentre clinical trials Reference Neuwirth, Braun and Claeys3 and there are guidelines to assure consistent recording and analysis across laboratories. Reference Nandedkar, Barkhaus, Stålberg, Neuwirth and Weber4

MUNIX is a candidate biomarker of longitudinal lower motor neuron (LMN) dysfunction and has been adopted in limb muscles of patients with amyotrophic lateral sclerosis (ALS) as an outcome of early-phase trials. Reference Neuwirth, Braun and Claeys3 However, MUNIX of brainstem-innervated muscles remains technically challenging, which limits its application in monitoring LMN progression in bulbar-ALS. MUNIX of facial nerve-innervated muscles has been explored as a potential correlate for bulbar dysfunction, but there has been poor discrimination between scores from patients with bulbar weakness and controls. Reference Grimaldi, Duprat, Grapperon, Verschueren, Delmont and Attarian5

Given the limitations associated with longitudinal assessment of tongue and facial denervation, examination of the upper trapezius (UTrap) may be a more feasible surrogate measure of bulbar LMN dysfunction. Despite UTrap’s motor neurons likely localizing in the cervical spine, UTrap neurogenic denervation was demonstrated by needle EMG in early ALS bulbar weakness. Reference Xu, Zheng, Zhang and Fan6 In two small studies, MUNIX of the UTrap (MUNIX-Trapezius) had lower mean scores in ALS patients compared to controls. Reference Grimaldi, Duprat, Grapperon, Verschueren, Delmont and Attarian5,Reference Stein, Kobor, Bogdahn and Schulte-Mattler7 Although adequate intra-rater reliability was recently reported in healthy volunteers, Reference Cao, Gu and Zhang8 there is no data on inter-rater reliability to further validate its utility in multicentre studies.

The objective of this study is to 1) conduct a systematic review of studies reporting MUNIX-Trapezius scores and reliability data in control participants; 2) perform MUNIX-Trapezius in control volunteers to assess inter- and intra-rater intraclass correlations (ICC); and 3) perform a meta-analysis of pooled MUNIX-Trapezius measurement parameters to determine the utility of this measure as a marker of bulbar dysfunction in future ALS studies.

For the systematic review, Medline and EMBASE were searched in April 2022 using the terms (“MUNIX” OR “motor unit number index”) AND (“trapezius” OR “spinal accessory nerve” OR “accessory nerve”) without language or date filters (Supplementary A.1). Inclusion criteria were original articles reporting MUNIX-Trapezius of control participants. Excluded were conference abstracts and non-peer-reviewed publications. Two independent reviewers screened and extracted data from eligible articles following the PRISMA 2020 guidelines.

For assessing reliability, we enrolled volunteers aged 18 years and older without a medical history or exposure to medications associated with a risk of neuropathy. The study was approved by the local ethics board and written informed consent was obtained from all volunteers. Participants were seated upright with the active electrode (E1) placed over the motor point of the UTrap (about mid-point from C7 to acromion). The E2 electrode was placed over the contralateral acromion to ensure an isoelectric recording and to avoid volume-conducted potentials from ipsilateral co-activated muscles. We stimulated the right spinal accessory nerve at the posterior site, making all the efforts to achieve supramaximal CMAP, including multiple changes in E1 positioning. Reference Nandedkar, Barkhaus, Stålberg, Neuwirth and Weber4 CMAP baseline-peak amplitudes were recorded and filtered (2–10,000 Hz). Twenty 500-ms SIP epochs were recorded and filtered (20–10,000 Hz) at five-increasing levels of voluntary shoulder shrug. All tests were performed on a Natus VikingQuest™ v22 system. Two or three unilateral MUNIX sessions were performed 30 minutes apart by two blinded raters with all electrodes and markings removed and cleared in-between tests. Two sessions were performed by a novice neurophysiology fellow (Rater 1) and one session by a board-certified neurophysiologist with prior MUNIX experience (Rater 2).

Mean MUNIX values, standard deviation (SD), and 95% confidence interval (95%CI) of the mean were reported. Inter- and intra-rater reproducibility was calculated using two-way random effects model with multiple raters intraclass correlation (ICC[2,k]). The coefficient of variability (CoV) was calculated as the SD over the mean with bootstrap 95%CI estimated (10,000 resamples with replacement). Rater 1 test-retest data were used to calculate intra-rater reproducibility, whereas Rater 1 test and Rater 2 test data were used for inter-rater reproducibility. Bland–Altman plots demonstrated inter- and intra-rater agreement. A minimum sample size of 10 participants with two raters’ repeated measures provided 83% power to detect an inter-rater ICC of 0.85 and a null hypothesis ICC of 0.2 at two-sided alpha 0.05. A random-effects meta-analysis of single-group MUNIX means was estimated using the inverse variance method and DerSimonian-Laird τ2 estimator. Analyses were computed using R (metafor package).

There were four published studies reporting MUNIX-Trapezius for a total of 203 control volunteers (Figure A.1). The pooled mean MUNIX-Trapezius was 176.2 (95%CI 155.7; 196.7) in a meta-analysis of all available data including our enrolled cohort (Figure 1). There was significant heterogeneity in mean MUNIX values (I2 76%), along with variability in age and sampling technique across studies (Table 1). Mean age varied across studies (Figure A.2) and moderated mean MUNIX-Trapezius values in a meta-regression model (Figure 2).

Figure 1: Forest plot of mean MUNIX of the upper trapezius in healthy volunteers from four published studies, in addition to data from this study. 95%CI of mean CoV for Cao et al. was estimated using the Mean ± (SD/√n × 1.96) from their published data. * n = 20; ** n = 10.

Figure 2: Mean MUNIX of the upper trapezius was significantly moderated by mean age across four published studies, in addition to data from this study. Mixed effect meta-regression model was fitted with DerSimonian-Laird estimator for t2.

Table 1: Demographics and qualitative summary of MUNIX techniques used among studies

* Estimated SD.

In our study, 20 volunteers (10 females) with mean age of 33 years (SD 9, range 23–56) were enrolled. Mean MUNIX was 209.6 (SD 78) without a floor or ceiling effect, while mean CMAP baseline-to-peak amplitude was 9.5 mV (SD 2.6). Inter-rater ICC (n = 10) of 0.86 indicated adequate reliability between a novice and an experienced rater. Intra-rater reliability (n = 20) performed by Rater-1 revealed excellent agreement, similar to data reported by Cao et al. Reference Cao, Gu and Zhang8 (Figure 1). Conforming to the MUNIX guidelines, inter- and intra-rater CoVs were below 20% with excellent agreement among raters as indicated by the Bland–Altman plots (Figure 3).

Figure 3: Bland Altman plots of intra- and inter-rater agreement. (A) Intra-rater agreement of MUNIX scores from Rater 1 test and re-test sessions. (B) Inter-rater agreement of MUNIX scores from Rater 1 test and Rater 2 test sessions. This plot would suggest that test-retest differences exceeding 50% CoV are likely more than that expected from test variability alone.

MUNIX has been demonstrated as a reliable biomarker of LMN dysfunction in limbs of patients with ALS. As a marker of bulbar LMN dysfunction, MUNIX-Trapezius has emerged as a candidate biomarker and a more reliable alternative to facial muscles. Reference Grimaldi, Duprat, Grapperon, Verschueren, Delmont and Attarian5,Reference Stein, Kobor, Bogdahn and Schulte-Mattler7,Reference Querin, Lenglet and Debs9 In our systematic review, mean MUNIX values were heterogeneous across studies in controls and reliability data for this measure were incomplete, which limits its interpretation and implementation as a marker of bulbar LMN dysfunction in multicentre ALS studies. In contrast, we found that well-trained examiners following a systematic testing approach demonstrated excellent inter- and intra-rater reliability of this parameter in control participants.

MUNIX is susceptible to variability in SIP sampling, particularly at low contraction levels. Reference Fatehi, Grapperon, Fathi, Delmont and Attarian2 This may partially account for the heterogeneity across studies and outlier mean and SD values reported by Stein et al. Reference Stein, Kobor, Bogdahn and Schulte-Mattler7 These authors enrolled a younger sample and employed a continuous SIP sampling method at gradually increasing voluntary muscle contraction with post hoc extraction of shorter-length epochs, contrary to the recommended stepwise SIP recording protocol. Also, mean age variance modulated MUNIX-Trapezius and contributed to in-between study heterogeneity. At an individual level, Cao et al. Reference Cao, Gu and Zhang8 reported variability in MUNIX-Trapezius, as well as MUNIX biceps brachii, within age groups below 60 years, while MUNIX tibialis anterior and abductor pollicis brevis were stable up to the 60-year group. Future studies should further explore motor unit changes in proximal muscles in younger adults.

Following the guidelines for MUNIX acquisition, Reference Nandedkar, Barkhaus, Stålberg, Neuwirth and Weber4 MUNIX recorded at the UTrap in our sample of control participants had reliable test–retest performance between a novice and senior rater. This indicates the robustness of the measure and supports its use in multicentre studies where varying degrees of MUNIX expertise is expected. Reference Neuwirth, Braun and Claeys3 Test–retest reproducibility was excellent when performed by a novice rater in our enrolled sample, further supporting studies with longitudinal measures as previously reported by Cao et al. Reference Cao, Gu and Zhang8 While the inter- and intra-rater ICCs from healthy controls represent intrinsic technical variability, future studies should reassess MUNIX-Trapezius reproducibility in disease populations to account for potential patient-specific factors.

MUNIX of the trapezius as a bulbar LMN measure in ALS is a promising alternative to facial nerve-innervated muscles. The trapezius is less susceptible to a floor effect since its supramaximal CMAP – a key component for MUNIX calculation – is larger compared to CMAP from facial muscles. Moreover, in ALS, trapezius activation is relatively preserved until advanced stages, allowing for feasible SIP recording as the disease progresses. It can also be performed with patients seated upright and wearing non-invasive ventilation masks, avoiding the need for wheelchair transfers or interruption of non-invasive ventilation. While cross-sectional MUNIX comparisons could discriminate patients with ALS from controls, Reference Grimaldi, Duprat, Grapperon, Verschueren, Delmont and Attarian5,Reference Stein, Kobor, Bogdahn and Schulte-Mattler7 longitudinal construct validity studies correlating MUNIX to trapezius and clinical measures of speech and swallowing in patients with and without bulbar symptoms are required. Advanced speech assessment tools, such as speech-and-pause analysis of spoken passage recordings, Reference Barnett, Green and Marzouqah10 can anchor bulbar function to correlate with MUNIX to trapezius measures over time.

Limitations of this study include the small sample size which reduces the precision of the pooled estimates and meta-regression inferences. The generalizability of our data is limited given the small and younger sample of controls from a single site, despite our intra-rater ICC yielding similar findings to previous studies. Given its motor innervation, determining whether MUNIX-Trapezius reflects an adequate proxy for bulbar function is also limited without further investigation.

In conclusion, MUNIX to upper trapezius in healthy volunteers is a reliable measure with excellent inter- and intra-rater reproducibility. With further longitudinal construct and pharmacological surrogacy validation studies, this measure can serve as a reliable biomarker of bulbar region LMN function in patients with ALS.

Supplementary Material

To view supplementary material for this article, please visit http://dx.doi.org/10.1017/cjn.2023.20.

Acknowledgements

The authors thank Dr. Aude-Marie Grapperon and collaborators for sharing additional data of MUNIX of the upper trapezius in healthy controls from the Grimaldi et al. study.

Statement of Authorship

AA and LP are co-first authors and contributed equally to this manuscript. KEJ and LZ are co-senior authors and contributed equally to this manuscript. Authors AA, LP, MEB, LR, and LZ contributed to the study conceptualization and design. AA, LP, and DF participated in data collection. AA, LP, DF, MEB, LR, and KJ were responsible for analysis of the data. AA, LP, DF, MEB, LR, KJ, and LZ contributed to manuscript writing and critique. All authors critically reviewed and approved the final manuscript.

Funding

This study was funded by University of Toronto Slamen Fast New Initiatives Grant, the generosity of philanthropic gifts to the Sunnybrook Foundation and our ALS research program.

Conflict of Interest

The authors have no conflicts of interest to declare.

References

Nandedkar, SD, Nandedkar, DS, Barkhaus, PE, Stalberg, EV. Motor Unit Number Index (MUNIX). IEEE Trans Biomed Eng. 2004;51:220911.CrossRefGoogle ScholarPubMed
Fatehi, F, Grapperon, AM, Fathi, D, Delmont, E, Attarian, S. The utility of motor unit number index: a systematic review. Neurophysiol Clin. 2018;48:2519.CrossRefGoogle ScholarPubMed
Neuwirth, C, Braun, N, Claeys, KG, et al. Implementing Motor Unit Number Index (MUNIX) in a large clinical trial: real world experience from 27 centres. Clin Neurophysiol Off J Int Fed Clin Neurophysiol. 2018;129:175662.CrossRefGoogle Scholar
Nandedkar, SD, Barkhaus, PE, Stålberg, EV, Neuwirth, C, Weber, M. Motor unit number index: guidelines for recording signals and their analysis. Muscle Nerve. 2018;58:37480.10.1002/mus.26099CrossRefGoogle ScholarPubMed
Grimaldi, S, Duprat, L, Grapperon, AM, Verschueren, A, Delmont, E, Attarian, S. Global motor unit number index sum score for assessing the loss of lower motor neurons in amyotrophic lateral sclerosis: ALS Global MUNIX Sum Score. Muscle Nerve. 2017;56:2026.10.1002/mus.25595CrossRefGoogle ScholarPubMed
Xu, YS, Zheng, JY, Zhang, S, Fan, DS. Upper trapezius electromyography aids in the early diagnosis of bulbar involvement in amyotrophic lateral sclerosis. Amyotroph Lateral Scler. 2011;12:3458.10.3109/17482968.2011.582647CrossRefGoogle ScholarPubMed
Stein, F, Kobor, I, Bogdahn, U, Schulte-Mattler, WJ. Toward the validation of a new method (MUNIX) for motor unit number assessment. J Electromyogr Kinesiol. 2016;27:737.CrossRefGoogle ScholarPubMed
Cao, B, Gu, X, Zhang, L, et al. Reference values for the motor unit number index and the motor unit size index in five muscles. Muscle Nerve. 2020;61:65761.10.1002/mus.26837CrossRefGoogle ScholarPubMed
Querin, G, Lenglet, T, Debs, R, et al. The motor unit number index (MUNIX) profile of patients with adult spinal muscular atrophy. Clin Neurophysiol. 2018;129:233340.CrossRefGoogle ScholarPubMed
Barnett, C, Green, JR, Marzouqah, R, et al. Reliability and validity of speech & pause measures during passage reading in ALS. Amyotroph Lateral Scler Front Degener. 2020;21:4250.CrossRefGoogle ScholarPubMed
Figure 0

Figure 1: Forest plot of mean MUNIX of the upper trapezius in healthy volunteers from four published studies, in addition to data from this study. 95%CI of mean CoV for Cao et al. was estimated using the Mean ± (SD/√n × 1.96) from their published data. * n = 20; ** n = 10.

Figure 1

Figure 2: Mean MUNIX of the upper trapezius was significantly moderated by mean age across four published studies, in addition to data from this study. Mixed effect meta-regression model was fitted with DerSimonian-Laird estimator for t2.

Figure 2

Table 1: Demographics and qualitative summary of MUNIX techniques used among studies

Figure 3

Figure 3: Bland Altman plots of intra- and inter-rater agreement. (A) Intra-rater agreement of MUNIX scores from Rater 1 test and re-test sessions. (B) Inter-rater agreement of MUNIX scores from Rater 1 test and Rater 2 test sessions. This plot would suggest that test-retest differences exceeding 50% CoV are likely more than that expected from test variability alone.

Supplementary material: PDF

Abrahao et al. supplementary material

Abrahao et al. supplementary material 1

Download Abrahao et al. supplementary material(PDF)
PDF 9.4 KB
Supplementary material: PDF

Abrahao et al. supplementary material

Abrahao et al. supplementary material 2

Download Abrahao et al. supplementary material(PDF)
PDF 85.1 KB
Supplementary material: PDF

Abrahao et al. supplementary material

Abrahao et al. supplementary material 3

Download Abrahao et al. supplementary material(PDF)
PDF 159.4 KB