Hostname: page-component-cd9895bd7-fscjk Total loading time: 0 Render date: 2024-12-23T12:48:17.618Z Has data issue: false hasContentIssue false

Delayed recognition of esophageal intubation

Published online by Cambridge University Press:  21 May 2015

Kenneth C. Dittrich*
Affiliation:
Department of Emergency Medicine, King Fahad National Guard Hospital, Riyadh, Saudi Arabia
*
Department of Emergency Medicine, King Fahad National Guard Hospital, Riyadh, Saudi Arabia; [email protected]

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

It is important for clinicians to be aware of the sensitivity and limitations of commonly used methods to confirm endotracheal tube placement. Overreliance on insensitive indicators can lead to delayed recognition of esophageal intubation. The case presented highlights this concern.

Type
Case Report • Observations
Copyright
Copyright © Canadian Association of Emergency Physicians 2002

References

1.Cho, KC.Visualization of the extrahepatic segment of the ligamentum teres: a sign of free air on plain radiographs. Radiology 1997;202:6514.CrossRefGoogle ScholarPubMed
2.Sakles, JC, Laurin, EG, Rantapaa, AA, Panacek, E.Airway management in the emergency department: A one-year study of 610 tracheal intubations. Ann Emerg Med 1998;31:32532.Google Scholar
3.Schwartz, DE, Mattay, MA, Cohen, NH.Death and other implications of emergency airway management in critically ill adults: a prospective investigation of 297 tracheal intubations. Anaesthesiology 1995;82:36776.CrossRefGoogle Scholar
4.Mort, TC.Incidence and risks leading to cardiac arrest following emergency intubation [abstract]. Crit Care Med 1994;22:A137.CrossRefGoogle Scholar
5.Holland, R, Webb, RK, Runciman, WB.Oesophageal intubation: an analysis of 2000 incident reports. Anaesth Intensive Care 1993;21:60810.CrossRefGoogle ScholarPubMed
6.Wilson, CW, Benumof, JL.Respiration in anaesthesia pathophysiology and clinical update. Anesth Clin North Am 1998;16:2975.CrossRefGoogle Scholar
7.Clyburn, P, Rosen, M.Accidental oesophageal intubation. Br J Anaesth 1994;73:5563.CrossRefGoogle ScholarPubMed
8.Andersen, KH, Schultz-Lebahn, T.Oesophageal intubation can be undetected by auscultation of the chest. Acta Anaesthesiol Scand 1994;38:5802.CrossRefGoogle ScholarPubMed
9.Andersen, KH, Registrar, A, Hald, A.Assessing the position of the tracheal tube. The reality of different methods. Anaesthesia 1989;44:9845.Google Scholar
10.Haridas, RP.Condensation on tracheal tubes is commonly seen with oesophageal intubation. Br J Anaesth 1995;75:1156.Google Scholar
11.Smith, GM, Reed, JC, Choplin, RH.Radiographic detection of esophageal malposition of endotracheal tubes. AJR 1990;154:236.Google Scholar
12.Ballester, EE, Torres, A, Rodriguez-Roisin, R, Agusti-Vidal, A.Pneumoperitoneum: an unusual manifestation of improper oral intubation. Crit Care Med 1985;13:1389.CrossRefGoogle ScholarPubMed
13.Ornato, JP, Shipley, JP, Racht, EM, et al. Multicenter study of aportable, hand size, calorimetric end-tidal carbon dioxide detection device. Ann Emerg Med 1992;21:51823.CrossRefGoogle Scholar
14.Li, J.Capnography alone is imperfect for endotracheal tube placement confirmation during emergency intubation. J Emerg Med 2001;20:2239.CrossRefGoogle ScholarPubMed
15.EasyCap ETCO2 Detector Product Information. Hayward (CA): Nellcor, Inc; 1992.Google Scholar
16.O’Connor, RE, Swor, RA.Verification of endotracheal tube placement following intubation. Prehosp Emerg Care 1999;3:24850.Google Scholar
17.Wee, MYK.The esophageal detector device: a rapid and accurate method for assessing tracheal versus esophageal intubation in the porcine model. Ann Emerg Med 1992;21:10736.Google Scholar
18.Williams, KN, Nunn, FJ.The esophageal detector device. Anaesthesia 1989;44:4124.CrossRefGoogle Scholar
19.Li, J.A prospective multicenter trial testing the SCOTI device for confirmation of endotracheal tube placement. J Emerg Med 2001;20:2319.CrossRefGoogle ScholarPubMed
20.Andres, AH, Langenstein, H.The esophageal detector device is unreliable when the stomach has been ventilated. Anesthesiology 1999;91:5668.CrossRefGoogle ScholarPubMed
21.Kasper, CL, Deem, S.The self-inflating bulb to detect esophageal intubation during emergency airway management. Anaesthesiology 1998;88:898902.Google Scholar
22.Bozeman, WP, Hexter, D, Liang, HK, Kelen, GD.Esophageal detector device versus detection of end-tidal carbon dioxide level in emergency intubation. Ann Emerg Med 1996;27:5959.CrossRefGoogle ScholarPubMed
23.Pelucio, M, Halligan, L, Dhindsa, H.Out-of-hospital experience with the syringe esophageal detector device. Acad Emerg Med 1997;4:5638.CrossRefGoogle ScholarPubMed