Hostname: page-component-586b7cd67f-vdxz6 Total loading time: 0 Render date: 2024-11-25T09:35:24.218Z Has data issue: false hasContentIssue false

Improving Cleaning Validation Utilizing Adenosine Triphosphate Technology

Published online by Cambridge University Press:  16 September 2024

Mehvish Siddiqui
Affiliation:
Methodist Specialty and Transplant Hospital
Rosemary Garcia
Affiliation:
Methodist Specialty and Transplant Hospital
Rosa Lozano
Affiliation:
Methodist Healthcare System

Abstract

Core share and HTML view are not available for this content. However, as you have access to this content, a full PDF is available via the ‘Save PDF’ action button.

Background: Thorough cleaning and disinfection of high-touch surface areas in hospital inpatient rooms remain vital parts of effective strategies in reducing hospital-acquired infections (HAIs). Currently, Methodist Specialty & Transplant Hospital (MHST) inconsistently utilizes fluorescent marking for terminal cleaning validation. Without quantitative results, it’s difficult to measure the effectiveness of cleaning. To ensure MHST is maintaining a safe and clean environment for patients & staff, MHST implemented a comprehensive cleaning verification program to include adenosine triphosphate (ATP) technology. We aimed to establish the program with baseline readings, and an overall weekly passing score of 95% for all tested inpatient rooms. Methods: To achieve sustained improvement, we needed to monitor, educate, and have periodic performance feedback to individuals and stakeholders. Key stakeholders (IP, EVS, Operations Leadership, Nursing Leadership representative) were identified, and a weekly meeting was established to discuss the planning and implementation of the ATP program. Some key actions included: standardization of brand of luminometer- device to measure ATP for microbial contamination; establishment of 16 high surface touch points to be tested; partnership with IT to create a database & dashboard for ATP results & data analysis; training of ATP device to all personnel who will be utilizing ATP device; establishment of a threshold for a “pass” clean (relative light unit [RLU] less than or equal to 45). Summary of Results: After baseline testing, the average weekly pass score met goal at 95 percent for all tested rooms. The bedside table located on the 2W floor was the location that failed the most (3 instances). Conclusions: Our program implementation project aimed to improve terminal cleaning validation utilizing ATP technology in inpatient rooms, was successfully implemented. Equipped with quantitative results, the MHST team, was able to verify cleaning quickly and efficiently without any confusion, as it may have been with the previous verification method of fluorescent marking. The partnership between Infection Prevention (IP) & Environmental Services (EVS) was crucial in the implementation of this process improvement- from participating in training together to understanding and sharing ATP pass/fail score data.

Type
Environmental Cleaning
Creative Commons
Creative Common License - CCCreative Common License - BY
This is an Open Access article, distributed under the terms of the Creative Commons Attribution licence (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted re-use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright