An electro-mechanical method of simultaneous component separation is suggested as an alternative to mechanical systems. Based on the commonly used weighbeam, employing a motor driven leadscrew, poise weight, selsyn repeater circuit and counter, component separation is proposed by means of the selsyn differential circuit.
The use of the selsyn motor as a direct or differential telemeter mechanism is well known, and as such, has many industrial applications. Such use, applied to the aerodynamic balance, offers the advantage of avoiding many of the difficulties associated with design and in particular, the construction of a mechanically independent and simultaneous measuring instrument.