Hostname: page-component-cd9895bd7-jkksz Total loading time: 0 Render date: 2024-12-22T11:16:17.663Z Has data issue: false hasContentIssue false

Active control of fan noise from high-bypass ratio aeroengines: a numerical study

Published online by Cambridge University Press:  04 July 2016

P. Traub
Affiliation:
MTU Aero EnginesMunich, Germany
F. Kennepohl
Affiliation:
MTU Aero EnginesMunich, Germany
K. Heinig
Affiliation:
MTU Aero EnginesMunich, Germany

Abstract

Under the national research project, dubbed Turbotech II, in which MTU Aero Engines, DLR Institute of Propulsion Technology and EADS Corporate Research Centre participate, active noise control (ANC) has been tested with a scale model fan of one metre diameter for a high bypass ratio aeroengine. MTU’s task in this project was to develop a computer code to predict the sound field in the intake duct of the fan-rig by the use of active control. The primary objective of the numerical study was to specify numbers of actuators (loudspeakers) and error sensors (microphones) and their positioning to control the harmonic sound power, radiated upstream to the duct intake. The computer model is based on the geometry of an annular or circular duct of rigid walls and infinite length, containing a subsonic axial uniform flow. The modal amplitudes of the primary sound field are input data. The actuators are modelled by acoustic monopoles. Two control algorithms have been used for achieving the control objective. The first consists simply in the reduction of the in-duct mean squared pressures. The second, so called modal control, is designed to cancel dominant modes selectively. Numerical results are presented using a typical configuration of wall mounted actuators and error sensors in the form of a number of rings uniformly distributed along the length of the intake duct. Guidelines have also been derived to design a favourable configuration of actuators and sensors. The findings of the numerical study are compared with the results of the ANC tests.

Type
Research Article
Copyright
Copyright © Royal Aeronautical Society 2001 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Enghardt, L., zhang, Y. and Neise, W. Experimental verification of a radial mode analysis technique using wall-flush mounted sensors, 137th meeting of the Acoustical Society of America, Berlin, 15-19 March 1999.Google Scholar
2. Tapken, U., Zhang, Y., Enghardt, L. and Neise, W. Modal concept for active noise control in circular or annular ducts, RTO Tagung, Berlin, May 2000.Google Scholar
3. Tapken, U., Enghardt, L., Schimming, P. and Neise, W. Active control of fan noise from high-bypass ratio aero engines: experimental results, 8th CEAS European Propulsion Forum, Nottingham, 28 March 2001.Google Scholar