Absolute Calibration of Photoelectric Diodes

Published online by Cambridge University Press:  06 March 2019

R. H. Day
Affiliation:
Air Force Weapons Laboratory Kirtland AFB, New Mexico 87117
E. J. T. Burns
Affiliation:
Air Force Weapons Laboratory Kirtland AFB, New Mexico 87117
Get access

Abstract

Photoelectric diodes with aluminum photocathod.es have been calibrated in the energy range from 0.1 keV to 1 keV with a multielement Henke X-ray tube system using regenerative monochromatic filters. The calibration is performed at six energies: (1) Be - (0.109 keV) , (2) C - Kα (0.277 keV), (3) Ti – Lα1, 2 (0.452 keV) , (4) Fe – Lα1, 2 (0.705 keV), (5) Cu – Lα1, 2 (0.930 keV), and (6) Al – Kαl, 2 (1.487 keV). Several different 99.9%, (1000 series) aluminum foils were calibrated for use as cathodes. In addition, the average energy per electron ion pair, W, has been measured for methane at these same energies.

Type
Laser Analysis
Copyright
Copyright © International Centre for Diffraction Data 1975

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. McKee, L. L., Burns, E. J. T., Lindstrand, R. A., Economou, N. P., “100 Joule CO2 Laser-Polyethylene Slab Interaction,” Bull. Am. Phys. Soc., Series II, Vol. 19, No. 9, p. 922.Google Scholar
2. Turchi, P. J. and Baker, W. L., J. Appl. Phys. 44, 4936 (1973).Google Scholar
3. Mosher, D., Stephanakis, S. J., Vitkovitsky, I. M., Dozier, C. M., Levine, L. S., and Nagel, D. J., J. Appl. Phys. 23, 429 (1973).Google Scholar
4. Kerns, J. R. and Johnson, D. J., “Study of an Electron-Beam Discharge into a Vacuum Diode with Polyethylene Anode,” J. Appl. Phys., 45 , 5225-5228 (1974).Google Scholar
5. Johnson, D. J., “Two Systems for Measurement of High-Intensity Vacuum Ultraviolet Plasma Radiation,” AFWL-TR-74-43 (1974).Google Scholar
6. Youel, R., “Calculation of the Sensitivity of the X-Ray Photodiode,” AWRE Diagnostic Memo 7169.Google Scholar
7. Henke, B. L. and Lester, M. A., “Techniques of Low Energy X-Ray Spectroscopy,” in Pickles, W. L., Barrett, C. S., Newkirk, J. B., and Ruud, C. O., Editors, Advances in X-Ray Analysis, Vol. 18, p. 76106, Plenum Press (1975).Google Scholar
8. Lyons, P. B., private communications.Google Scholar
9. Samson, J. A. R., Techniques of Vacuum Ultraviolet Spectroscopy, p. 265, John Wiley and Sons, (1967).Google Scholar
10. Cairns, R. B. and Samson, J. A. R., “Metal Photocathodes as Secondary Standards for Absolute Intensity Measurements in the Vacuum Ultraviolet,” J. Opt. Soc. Am. 56, 1568-1537 (1966).Google Scholar