Hostname: page-component-586b7cd67f-t8hqh Total loading time: 0 Render date: 2024-11-23T15:28:45.330Z Has data issue: false hasContentIssue false

XRF Technique as a Method of Choice for On-Site Analysis of Soil Contaminants and Waste Material

Published online by Cambridge University Press:  06 March 2019

Starislaw Piorek*
Affiliation:
Princeton Gamma-Tech A Member of the Outokumpu Group 1200 State Road Princeton, New Jersey 08540
Get access

Abstract

Recent years were marked by a rapid increase of interest in the ase of x-ray fluorescence for on-site chemical characterization of contaminated soils and waste materials.

The known advantages of the XRF technique, such as capability of simultaneous, multielement analysis, speed of measurement (10 to 100 seconds), little or no sample preparation, wide concentration range, “portability,“ and ease of integration into environmental monitoring station(s), make it specifically suited for this application.

Major difficulties still inhibiting wider use of the XRF for hazardous waste screening stem from the lack of suitable calibration samples and proper protocols, as well as from the low awareness of the industry about the technique.

Type
Research Article
Copyright
Copyright © International Centre for Diffraction Data 1989

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. USEPA Data Quality Objectives for Remedial Response Activities Development Process,” EPA/540/G-7/003, 1987.Google Scholar
2. Jarvinen, M-L., Sipila, H. - “Effect of Pressure and Admixture of Neon Penning Mixtures on Proportional Counter Resolution,” Nucl. Instr. Meth. 193 (1982), pp. 5356.Google Scholar
3. Piorek, S., Rhodes, J.R. - “Application of a Microprocessor Eased Portable Analyzer to Rapid nondestructive Alloy Identification,“ Advances in Instrumentation, Vol. 41, Part 3, pp. 1355-1368, ISA, 1986.Google Scholar
4. Piorek, S., Rhodes, J.R. - “A Hew Calibration Technique for X-Ray Analyzers Used in Hazardous Waste Screening,” Proceedings of the 5th National Conference on Hazardous Wastes and Hazardous Materials, April 19-21, 1988, Las Vegas, pp. 428-433.Google Scholar
5. Gaskill, A., Estes, E.D., Hardison, D.L. - “Evaluation of Techniques for Determining Chlorine in Used Oils,” Res. Triangle Institute Project #472U-3255-05, Contract Number 68-01-7075, August 1987.Google Scholar