Hostname: page-component-586b7cd67f-l7hp2 Total loading time: 0 Render date: 2024-11-23T15:00:31.937Z Has data issue: false hasContentIssue false

X-ray Capillary Microbeam Spectrometer

Published online by Cambridge University Press:  06 March 2019

S. Larsson
Affiliation:
Chalmers University of Technology Physics Dept, S-412 96 Goteborg, Sweden
P. Engstrom
Affiliation:
Chalmers University of Technology Physics Dept, S-412 96 Goteborg, Sweden
A. Rindby
Affiliation:
Chalmers University of Technology Physics Dept, S-412 96 Goteborg, Sweden
B. Stocklassa
Affiliation:
National Laboratory of Forensic Science Linkoping, Sweden
Get access

Abstract

By utilizing the total reflecting properties of x-rays inside glass capillary tubes, intensive fine- or microbeams of x-rays can be attained. By using a conventional x-ray tube in combination with capillary technique, microbeams with a diameter of a few μm and with an intensity sufficient for trace elements, analyses have been achieved. By moving the sample, lineand areascan can be performed and trace element information can be directly superimposed on a micrograph from a built-in optical microscope.

The background of the capillary technique is reviewed and an EDXRF microbeam spectrometer for trace elements is described. Examples of applications for the microbeam spectrometer are given.

Type
Research Article
Copyright
Copyright © International Centre for Diffraction Data 1989

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Jones, K. W. and Gordon, B. M., Anal. Chem, 61: 5 (1989). 341.Google Scholar
2. Hirch, P. B., X-Ray Diffraction of Polycrystalline Materials. (Chapman and Hall, London 1960).Google Scholar
3. Pantell, R. H. and Chung, P. S., Appl. Opt. 18, (1979) 897.Google Scholar
4. Mosher, D. and Stephanakis, J., Appl. Phys. Lett. 29, (1976) 105.Google Scholar
5. Wettcrling, W. T. and Pound, R. V., Jour. Opt. Soc, Ann. 66, (1976) 1048.Google Scholar
6. Carpenter, D. A., Microbeam Analysis 1988 MAS/EMSA Conference, Milwaukee, WI, Aug 7-12, 1988.Google Scholar
7. Rindby, A., Nucl. Instrum, and Meth. A249, (1986) 536.Google Scholar
8. Engstrom, P., Larsson, S., Rindby, A. and Stocklassa, B., Nucl. Instrum, and Meth. B36, (1989) 222.Google Scholar
9. Stern, E. A., Kalman, Z., Lewis, A. and Lieberman, K., Appl. Opt. 27, (1988) 5135.Google Scholar
10. Rindby, A., Engstrom, P., Larsson, S. and Stocklassa, B., X-Ray Spectrom. 18, (1989) 109.Google Scholar