Hostname: page-component-586b7cd67f-l7hp2 Total loading time: 0 Render date: 2024-11-23T14:56:31.889Z Has data issue: false hasContentIssue false

Self Absorption Corrections for X-Ray Fluorescence Analysis of Aerosols

Published online by Cambridge University Press:  06 March 2019

T. G. Dzubay
Affiliation:
Chemistry and Physics Laboratory, National Environmental Research Center, Environmental Protection Agency, Research Triangle Park, NC 27711
R. O. Nelson
Affiliation:
Chemistry and Physics Laboratory, National Environmental Research Center, Environmental Protection Agency, Research Triangle Park, NC 27711
Get access

Abstract

A procedure is described for making self absorption corrections for x-ray fluorescence analysis of ambient air aerosols which are collected in two size ranges with a dichotomous sampler. Calculations for fine particles are based on the assumption of a uniform layer of accumulated deposit which has an exponentially decreasing depth profile within a membrane filter. Coarse particles are treated as spheres with a log normal mass distribution which is subject to modification by the sampling device. An average attenuation and the associated uncertainty is deduced for coarse particles by considering a wide variety of possible chemical compositions.

Type
Research Article
Copyright
Copyright © International Centre for Diffraction Data 1974

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Giauque, R. D., Goulding, F. S., Jaklevic, J. M., and Pehl, R. H., “Trace Element Determination with Semiconductor Detector X-Ray Spectrometers”, Anal. Chem. 45, 671681 (1973).Google Scholar
2. Rhodes, J. R. and Hunter, C. B., “Particle Size Effects in X-Ray Emission Analyses: Simplified Formulas for Certain Practical Cases”, X-Ray Spectrometry 113117 (1972).Google Scholar
3. Whitby, K. T., Husar, R. B., and Liu, B. Y. H., “The Aerosol Size Distribution of Los Angeles Smog”, J. Colloid and Interface Science 39, 177204 (1972).Google Scholar
4. Willeke, K., Whitby, K. T., Clark, W. E., and Marple, V. A., “Size Distributions of Denver Aerosols — A Comparison of Two Sites”, Atmospheric Environment 8, 609633 (1974).Google Scholar
5. Lundgren, D. A., “Mass Distribution of Large Atmospheric Particles”, Ph.D. Thesis, University of Minnesota (1973).Google Scholar
6. Husar, R. B., Whitby, K. T., and Liu, B. Y. H., “Physical Mechanisms Governing the Dynamics of Los Angeles Smog Aerosol”, J. Colloid Interface Sci. 39, 211224 (1972).Google Scholar
7. Dzubay, T. G. and Stevens, R. K., “Ambient Air Analysis with Dichotomous Sampler and X-Ray Fluorescence Spectrometer”, Environ. Sci. and Technol, to be published, (1974-1975).Google Scholar
8. Loo, B. W. and Jaklevic, J. M., “An Evaluation of the ERC Virtual Impactor”, Lawrence Berkeley Laboratory Publication, LBL-2468, Berkeley (1974).Google Scholar
9. Goulding, F. S. and Jaklevic, J. M., “X-Ray Fluorescence Spectrometer for Airborne Particulate Monitoring”, EPA Report No. EPA-R2-73-182 (1973).Google Scholar
10. Lockhart, L. B. Jr., Patterson, R. L. Jr., and Anderson, W. L., “Characteristics of Air Filter Media Used for Monitoring Airborrie Radioactivity”, NRL Report 6054 (1963).Google Scholar
11. Pich, J., “Theory of Aerosol Filtration by Fibrous and Membrane Filters”, in C. N. Davies, Editor, Aerosol Science, p. 223-285 (1966).Google Scholar
12. Dzubay, T. G. and Nelson, R. O., to be published.Google Scholar
13. Veigele, W. J., “Photon Cross Sections from 0.1 KeV to 1 MeV for Elements Z=1 to Z=94”. Atomic Data Tables, 5, 51111 (1973).Google Scholar