Hostname: page-component-586b7cd67f-r5fsc Total loading time: 0 Render date: 2024-11-23T15:14:58.104Z Has data issue: false hasContentIssue false

Quantitative Determination of Ga, Zn, Cu, Hi, Mn, and Cr by X-Ray Fluorescence in Laterites and Bauxites Using Two Evaluation Methods

Published online by Cambridge University Press:  06 March 2019

Hasso Schorin*
Affiliation:
IVIC, Centro de Ingeniería y Computación Apartado 1827, Caracas 1010-A, Venezuela
Get access

Extract

Laterites and bauxites are residual products derived from a wide variety of rocks by intensive chemical weathering under strongly oxidizing and leaching conditions. Generally the main constituents of these residues are Fe, Al and Ti present in form of hydroxides and/or oxides. The content of silica depends on the thoroughness of the leaching process. The behaviour of trace and minor elements as Ga, Zn, Cu, Ni, Mn and Cr during the laterite/bauxite formation is not yet well established. Precise and accurate analyses of these elements are a prerequisite for such investigations. In this paper the standard addition method is presented and the results are compared with those obtained by calibration standardization. The accuracy and the precision of the methods as well as the distinction limit and the limit of detection for each element are given.

Type
III. XRF Applications: Mineral and Geological
Copyright
Copyright © International Centre for Diffraction Data 1981

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Bertin, E. P., “Principle sand Practice of X-Ray Spectrometric Analysis“, Plenum Press, New York (1975).Google Scholar
2. Plesch, R., Praktische Fehlertheorie der Roentgenspektrometrie, X-Ray Spectrom, 7: 156 (1978).Google Scholar
3. Lichtfuss, R. und Bruemmer, G., Roentge fluoreszen analyse von Umwe1 ferelevanten Spurenelementen in Sedimenten und Boeden, Chem. Geol. 21:51 (1978).Google Scholar
4. Neeb, R., Analytical Chemistry of the Platinum Metals I.X-Ray Fluo-rimetric Determination of Microgram Amounts of Osmium, Z.Anal.Chemie 179:21 (1961).Google Scholar
5. Plech, R., Analytische Grundlagen der Siemens Rechenprograitime fuer die Roentgenspektrometrie, Siemens Zeitschrift 48:355 (1974).Google Scholar
6. Plech, R., Empirical MatrixC orrection in Practical X-Ray Spectrometry 5:142 (1976).Google Scholar
7. Kaiser, R. und Gottschalk, G., “Element are Tests zur Beurteilung von Messdaten, Bibliographisches Institut, Mannheim (1972).Google Scholar
8. Abbey, S., Calibration Standards, X-Ray Spectrom. 7:99 (1978).Google Scholar