Improved Techniques of Lattice Parameter Measurements Using two X-Ray Beams

Published online by Cambridge University Press:  06 March 2019

Seigo Kishino*
Affiliation:
Central Research Laboratory, Hitachi Ltd., Kokubunji, Tokyo 185, Japan
Get access

Abstract

Two kinds of improved techniques are described for precise measurement of lattice parameters with an accuracy of 1 ∼7x10-5, in both of which a differenoe of Bragg angles between two X-ray beams such as K α1 and K β1 is measured.

In the first technique, which was applied to relatively imperfect crystals such as gallium arsenide, gallium arsenide phosphide, and gallium phosphide, two different diffraction planes were utilized for two radiations such as CuK α1 and CuK β1 in order to reduce the difference of the Bragg angles to the order of several minutes of arc.

In the second technique, which was applied to a nearly perfect crystal such as silicon, a double crystal arrangement of parallel setting was used, where lattice parameter of the specimen was relatively measured in comparison with the one of the first crystal which was known beforehand.

Type
Research Article
Copyright
Copyright © International Centre for Diffraction Data 1972

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. For example, Clark, G. L., Editor, The Encyclopedia of X-Rays and Gamma Rays, Reinhold Publishing Co., New York (1963), p. 696.Google Scholar
2. Lonsdale, K., “Divergent-Beam X-Ray Photography of Crystals,Phil. Trans. Roy. Soc. London 240, 219(1947).Google Scholar
3. Bond, W. L., “Precision Lattice Constant Determination,Acta Cryst. 13, 814(1960).Google Scholar
4. Bubákobá, R. and Szmid, Z., “Proton Bombardment Damage in Silicon,Phys. Stat. Sol. 8, 105(1965).Google Scholar
5. Hart, M., “High Precision Lattice Parameter Measurements by Multiple Bragg Reflection Diffractometry,Proc. Roy. Soc. A309. 281(1969).Google Scholar
6. Kishino, S., “Determination of the Mole Fraction of GaP in GaAsP Single Crystal by A New X-Ray Diffraction Technique,Japan. J. appl. Phys. 10, 1113(1971).Google Scholar
7. Popović, S., “An X-Ray Diffraction Method for Lattice Parameter Measurements from Corresponding Kα1 and Kβ1 Reflections,J. Appl. Cryst. 4, 240(1971).Google Scholar
8. DuMond, J. W. M., “Theory of the Use of More Than Two Successive X-Ray Crystal Reflections to Obtain Increased Resolving Power,Phys. Rev. 52, 872(1937).Google Scholar
9. Kohra, K., Hashizume, H. and Yoshimura, J., “X-Ray Diffraction Topography Utilizing Double Crystal Arrangement of (+,+) or Non-Parallel (+,-) Setting,Japan J. appl. Phys. 9, 1029 (1970).Google Scholar
10. Bearden, J. A., “X-Ray Wavelengths,Rev. Mod. Phys. 39, 78 (1967).Google Scholar
11. Pearson, G. L. and Bardeen, J., “Electorical Properties of Pure Silicon and Silicon Alloys Containing Boron and Phosphorus,Phys. Rev. 75, 865(1949).Google Scholar
12. Horn, F. H., “Densitometric and Electorieal Investigation o£ Boron in Silicon,Phys. Rev, 97, 1521(1955).Google Scholar
13. Cohen, B. G., “X-Ray Measurement of Elastic Strain and Lattice Constant of Diffused Silicon,” Solid-State Electronics, Pergamon Press 1967, Great Britain, vol. 10, P. 33.Google Scholar
14. Kishino, S., Ogirima, M. and Kurata, K., “A Cross-Hatch Pattern in GaAsP Epitaxially Grown on GaAs Substrate,J. Electrochem. Soc. 119, 617(1972).Google Scholar