Hostname: page-component-586b7cd67f-t7fkt Total loading time: 0 Render date: 2024-11-27T04:42:19.225Z Has data issue: false hasContentIssue false

Diffracted Beam Monochromators for Powder Diffractometry

Published online by Cambridge University Press:  06 March 2019

E. M. Proctor
Affiliation:
Picker Corporation, Cleveland, Ohio 44110
T. C. Furnas
Affiliation:
Picker Corporation, Cleveland, Ohio 44110
W. F. Loranger
Affiliation:
Picker Corporation, Cleveland, Ohio 44110
Get access

Abstract

The efficiency and effectiveness of diffracted beam x-ray monochromators used in powder diffractometry have been described in so many ways that much confusion exists regarding their true performance. Although significant improvements in signal to noise ratios are readily achievable, and they offer a solution to the sample fluorescence problem, it is not without sacrifice to total intensity or achievable resolution or both. This paper discusses and describes a series of comparisons between filtered direct beam, LiF and graphite monochromators.

These comparisons include the considerations necessary for the appropriate selection of diffracted beam slit system, the effect of vertical divergence as a function of two theta for singly bent crystals, the effects of a non-uniformity of contribution over the length of the crystal, and the geometry necessary for the singly bent and doubly bent crystals. The total intensity and the resolution of LiF and graphite are discussed, in particular, it is noted that the performance of monochromators with randomly oriented samples is quite different than their performance with samples showing preferred orientation or grain effects.

A new diffracted beam monochromator based on the Rowland focusing geometry is described.

Type
Research Article
Copyright
Copyright © International Centre for Diffraction Data 1970

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Lang, A. R., “Diffracted Beam Monochromatization Techniques in X-Ray Diffractometry”, The Review of Scientific Instruments, 27, 1725 (1956).Google Scholar
Birks, L. S., Electron Probe Microanalysis. John Wiley and Sons, New York, (1963).Google Scholar
Wilson, A. J. C., Mathematical Theory of X-Ray Powder Diffractometry, N. V. Philips Gloeilampenfabrieken, Einchoven, (1963).Google Scholar
Langford, J. I., “Counter Diffractometer—The Effect of Axial Divergence on the Breadth of Powder Lines”, Journal of Scientific Instruments, 39, pp. 515516, (1962).Google Scholar
Birks, L. S., Electron Probe Microanalysis, John Wiley and Sons, New York, (1963).Google Scholar