Hostname: page-component-586b7cd67f-r5fsc Total loading time: 0 Render date: 2024-11-27T03:42:38.406Z Has data issue: false hasContentIssue false

Detection and Spectroscopy of Long Wavelength X-Rays

Published online by Cambridge University Press:  06 March 2019

William L. Baun*
Affiliation:
Air Force Materials Laboratory (MAYA) Wright-Patterson Air Force Base, Ohio 45433
Get access

Abstract

Instrumentation for spectrometry in the long wavelength X-ray region has been improved significantly in the last several years. In the area of excitation of soft X-rays, many changes have taken place. Secondary excitation source windows have been made much thinner and high power windowless and ultra thin windowed continuously pumped X-ray tubes have been developed. One source has been described which allows a choice of either primary or secondary excitation. Cold cathode techniques have been developed in which pressure control is achieved using an automatic pressure controller. Primary electron excitation has been revived and has become very important mainly due to the popularity of electron microbeam probe analysis. In the area of spectral dispersion, many improvements and innovations have been seen, recently in both grating and crystal spectrometers. Organic single crystals have been grown having 2d spacings up to about 100Ǻ and soap films have been fabricated with 2d spacing as large as 165Ǻ, allowing crystal spectrometers to be used to about 160Ǻ.

Type
Research Article
Copyright
Copyright © International Centre for Diffraction Data 1969

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

1. Kirkendall, T. D. and Varadi, P. F., “A Sealed Thin Window X-Ray Tube for Light and Heavy Element Excitation,” Anal. Chem. 39, 1342 (1967).Google Scholar
1a. Kirkendall, T. D., Varadi, P. F., and Naill, R. F., paper #5, “Energy Dispersion Analysis Using Sealed X-Ray Excitation Sources,” Abstracts, Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy, Cleveland, Ohio, March, 1969.Google Scholar
2. Henke, B. L., “Techniques of Low Energy X-Ray and Electron Physics: 50 to 1000 eV Region,” Proceedings of 2nd Symposium on Low Energy X- and Gamma Sources and Applications (ORNL-II C-10, p. 523, Sept. 1967).Google Scholar
3. Henke, B. L., “Some Notes on Ultrasoft X-Ray Fluorescence Analysis - 10 to 100Å Region,” in Mueller, , Mallett, and Fay, , Eds., Advances in X-Ray Analysis, Vol. 8, Plenum Press, New York, 1965, p. 269284.Google Scholar
4. Deslattes, R. D. and Simson, B., “Demountable High Power Source for Soft X-Ray Region,” Rev. Sci. Inst. 37, 753 (1966).Google Scholar
5. Mattson, R. A. and Ehlert, R. C., “The Application of a Soft X-Ray Spectrometer to Study the Oxygen and Fluorine Emission Lines from Oxides and Fluorides,” In Mallett, , Fay, and Mueller, , Eds., Advances in X-Ray Analysis, Vol. 9, Plenum Press, New York, 1966, p. 471486.Google Scholar
6. Sagawa, T., “Soft X-Ray Emission and Absorption Spectra of Light Metals, Alloys, and Alkali Halides,” in Fabian, D. J., Ed., Soft X-Ray Band Spectra, Academic Press, London, 1965, p. 2943.Google Scholar
7. Liefeld, R. J., “Soft X-Ray Emission spectra at Threshold Excitation,” in Fabian, D. J., Ed., Soft X-Ray Band Spectra, Academic Press, London, 1968, p. 133149.Google Scholar
8. Batson, L. M., Dimond, R. K., and Fabian, D. J., “Soft X-Ray Emission Spectra of Magnesium and Beryllium,” in Fabian, D. J., Ed., Soft X-Ray Band Spectra, Academic Press, London, 1968, p. 4558.Google Scholar
9. Holliday, J. E., “Soft X-Ray Emission Bands and Bonding for Transition Metals, Solutions and Compounds,” in Fabian, D. J., Ed., Soft X-Ray Band Spectra, Academic Press, London, 1968, p. 101131.Google Scholar
10. Davidson, F. O. and Wyckoff, R. W. G., “L and M Spectra in the Region 2-85Å,” in Mallett, , Fay, , and Mueller, , Eds., Advances in X-Ray Analysis, Vol. 9, Plenum Press, New York, 1966, p. 344354.Google Scholar
11. Hayasi, T. and Hayasi, Y.,. “Long Wavelength X-Ray Spectra of Beryllium, Boron, and Aluminum Emitted from Gas-Ion X-Ray Tube,” Sci. Rep., Tohoku Univ., 50, no. 4, 228 (1967).Google Scholar
12. Solomon, J. S. and Baun, W. L., “Performance and Applications of a Cold Cathode Soft X-Ray Source,” Technical Report AFML-TR-69-41, June, 1969.Google Scholar
13. Whatley, T. A., “Improved Diffraction Elements for Analysis in the Soft X-Ray Region,” paper #6, Abstracts, Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy, Cleveland, Ohio, March, 1969.Google Scholar
14. Baun, W. L. and White, E. W., “A Vacuum Spectrometer for Studying the Chemical Effect on Soft X-Ray Spectra,” in Advances in X-Ray Analysis, Vol. 13, Plenum Press, New York, 1970.Google Scholar
15. Compton, A. H. and Allison, S. K., X-Rays in Theory and Experiment, 2nd Ed., D. Van Nostrand Co., Inc., New York, 1935.Google Scholar
16. Deslattes, R. D., “Two Crystal, Vacuum Monochromator,” Rev. Sci. Instr. 38, 616 (1967).Google Scholar
17. Sawada, M. and Tsutsumi, K., “Source Scanning Type X-Ray Grating Spectrometer,” J. Appl. Phys. 40, 1950 (1969).Google Scholar
18. Weich, G., “Investigations of the LII,III X-Ray Emission Band of Al with a Hew Concave Grating Spectrograph,” Z. fur Physik 193, 490 (1966).Google Scholar
19. Crisp, R. S., “The Soft X-Ray L23 Emission Spectrum of Mg From Solid and Evaporated Targets,” Aust. J. Phys, 11, 449 (1958).Google Scholar
20. Grodski, J. J., “Photoelectric Detectors for 10-400 Å Photons,” Norelco Reporter XIV, 107 (1967).Google Scholar
21. Somer, T. A. and Graves, P. W., “Spiraltron Matrices as Windowless Photon Detectors for Soft X-Ray and Extreme UV,” 15th Nuclear Science Symposium, Oct. 1968.Google Scholar
22. Caruso, A. J. and Kim, H. H., “Method of Stretching Polypropylene for Use as Soft X-Ray Detector Windows,” Rev. Sci. Instr. 39, 1059 (1968).Google Scholar
23. Deslattes, R. D., Simson, B. G., and LaVilla, R. E., “Gas Density Stabilizer for Flow Proportional Counters,” Rev. Sci. Instr. 37, 596 (1966).Google Scholar
24. Henke, B. L. and Lent, R. E., “Some Recent Work in Low Energy X-Ray and Electron Analysis,” in Advances in X-Ray Analysis, Vol. 12, plenum Press, New York, 1969.Google Scholar
25. Boksenberg, A., “A New Detector for Spectrometry,” Anal. Chem. 41, #7, p. 87A (1969).Google Scholar