10 - Sprayed microdroplets: methods and applications

from SECTION C - SPECIMEN PREPARATION

Published online by Cambridge University Press:  04 August 2010

David C. Sigee
Affiliation:
University of Manchester
John Morgan
Affiliation:
University of Wales, Aberystwyth
Get access

Summary

Introduction

Perspective: directly deposited microdroplets

Electron probe X-ray microanalysis (EPXMA) is capable of yielding quantitative data from excited specimen volumes < 1 μm3. Thus, the analysis of fluid microvolumes in the range 10−11 to 10−10 litres is comfortably within the scope of this technique. For this reason, EPXMA was advocated at an early stage in its technological evolution for the analysis of nanolitre fluid volumes (Ingram & Hogben, 1967). Subsequently a number of laboratories have independently pursued physiological questions by the analyses of diverse biological fluids. This family of related microdroplet methods is described fully elsewhere in this volume by Roinel and Rouffignac (Chapter 11). However, in order that the sprayed microdroplet technique be seen in a realistic perspective a brief resumé of the more conventional ‘direct deposition’ microdroplet methods is provided here.

In general, two major variants of the microdroplet method are practised (Fig. 10.1).

  1. 1. Microdroplets of known volume. Microdroplets of known volume are dispensed from calibrated micropipettes, mounted on polished solid (bulk) support materials, then dehydrated by freeze-drying to produce the all-important microcrystallites that minimise X-ray absorption. They are then individually analysed by wavelength-dispersive spectrometry (WDS).

  2. 2. Microdroplets of unknown volume. Microdroplets of samples and standards of indeterminate volume are dispensed from constant-volume micropipettes, mounted on thin-film supports, then dehydrated by flash evaporation and subsequently analysed by energy-dispersive spectrometry (EDS). A selected list of the combinations of available options adopted by some of the major laboratories in this specialised field is presented in Table 10.1.

Type
Chapter
Information
X-ray Microanalysis in Biology
Experimental Techniques and Applications
, pp. 151 - 174
Publisher: Cambridge University Press
Print publication year: 1993

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

Save book to Kindle

To save this book to your Kindle, first ensure [email protected] is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Available formats
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

Available formats
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

Available formats
×