Skip to main content Accessibility help
×
Hostname: page-component-78c5997874-ndw9j Total loading time: 0 Render date: 2024-11-19T14:36:53.021Z Has data issue: false hasContentIssue false

Case 42 - Pseudoenhancement of small renal cysts

from Section 7 - Kidneys

Published online by Cambridge University Press:  05 November 2011

Fergus V. Coakley
Affiliation:
University of California, San Francisco
Get access

Summary

Imaging description

Renal cyst pseudoenhancement is the artifactual increase in CT density that can be seen in small (less than 15 mm in diameter) simple renal cysts after the intravenous administration of iodinated contrast material (Figure 42.1) [1–4]. Pseudoenhancement is not simply due to partial volume averaging, because the artifact occurs even in experimental phantom studies where the effects of partial volume averaging have been removed. Pseudoenhancement is believed to be a consequence of beam-hardening effects of the enhanced renal parenchyma combined with artifact introduced by the CT image reconstruction algorithm [1].

Importance

Solid renal masses are typically distinguished from renal cysts at CT by the presence of enhancement after the intravenous administration of iodinated contrast material, and an increase in density of 10 Hounsfield Units has generally been regarded as the threshold for enhancement [5]. Pseudoenhancement may therefore lead to mischaracterization of a small renal cyst as an enhancing neoplasm and unnecessary intervention.

Typical clinical scenario

Renal cysts are present in 20 to 40% of the population [6]. Small renal cysts are particularly common. In one study, 67 of 258 patients (26%) undergoing CT had one or more renal cysts (as proven by MRI) of 10 mm or less in diameter [7]. In another study, 38% of simulated cysts measuring up to 15mm in diameter demonstrated pseudoenhancement with an increase in density that ranged from 10.3 to 28.3 Hounsfield Units [8]. Factors that increase the likelihood of pseudoenhancement are smaller cyst size, higher background renal parenchymal enhancement, a higher number of CT detector rows, and higher kVp [1–3, 9–11].

Type
Chapter
Information
Pearls and Pitfalls in Abdominal Imaging
Pseudotumors, Variants and Other Difficult Diagnoses
, pp. 142 - 143
Publisher: Cambridge University Press
Print publication year: 2010

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

Maki, DD, Birnbaum, BA, Chakraborty, DP, et al. Renal cyst pseudoenhancement: beam-hardening effects on CT numbers. Radiology 1999; 213: 468–472.CrossRefGoogle ScholarPubMed
Coulam, CH, Sheafor, DH, Leder, RA, et al. Evaluation of pseudoenhancement of renal cysts during contrast-enhanced CT. Am J Roentgenol 2000; 174: 493–498.CrossRefGoogle ScholarPubMed
Bae, KT, Heiken, JP, Siegel, CL, Bennett, HF.Renal cysts: is attenuation artifactually increased on contrast-enhanced CT images?Radiology 2000; 216: 792–796.CrossRefGoogle ScholarPubMed
Birnbaum, BA, Jacobs, JE, Ramchandani, P.Multiphasic renal CT: comparison of renal mass enhancement during the corticomedullary and nephrographic phases. Radiology 1996; 200: 753–758.CrossRefGoogle ScholarPubMed
Bosniak, MA, Rofsky, NM.Problems in the detection and characterization of small renal masses. Radiology 1996; 200: 286–287.CrossRefGoogle ScholarPubMed
Tada, S, Yamagishi, J, Kobayashi, H, Hata, Y, Kobari, T.The incidence of simple renal cyst by computed tomography. Clin Radiol 1983; 34: 437–439.CrossRefGoogle ScholarPubMed
Chithriki, M, Joe, BN, Yeh, BM, et al. Incidental small hypoattenuating renal lesions: to follow or not to follow. Am J Roentgenol 2004; 182: S4.Google Scholar
Birnbaum, BA, Maki, DD, Chakraborty, DP, Jacobs, JE, Babb, JS.Renal cyst pseudoenhancement: evaluation with an anthropomorphic body CT phantom. Radiology 2002; 225: 83–90.CrossRefGoogle ScholarPubMed
Heneghan, JP, Spielmann, AL, Sheafor, DH, et al. Pseudoenhancement of simple renal cysts: a comparison of single and multidetector helical CT. J Comput Assist Tomogr 2002; 26: 90–94.CrossRefGoogle ScholarPubMed
Abdulla, C, Kalra, MK, Saini, S, et al. Pseudoenhancement of simulated renal cysts in a phantom using different multidetector CT scanners. Am J Roentgenol 2002; 179: 1473–1476.CrossRefGoogle Scholar
Wang, ZJ, Coakley, FV, Fu, Y, et al. Renal cyst pseudoenhancement at multidetector CT: what are the effects of number of detectors and peak tube voltage?Radiology 2008; 248: 910–916.CrossRefGoogle ScholarPubMed
Patel, NS, Yeh, BM, Qayyum, A, et al. The characterization of small hypoattenuating renal masses on contrast-enhanced CT. Am J Roentgenol 2004; 182: S5.Google Scholar

Save book to Kindle

To save this book to your Kindle, first ensure [email protected] is added to your Approved Personal Document E-mail List under your Personal Document Settings on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part of your Kindle email address below. Find out more about saving to your Kindle.

Note you can select to save to either the @free.kindle.com or @kindle.com variations. ‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi. ‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.

Find out more about the Kindle Personal Document Service.

Available formats
×

Save book to Dropbox

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Dropbox.

Available formats
×

Save book to Google Drive

To save content items to your account, please confirm that you agree to abide by our usage policies. If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account. Find out more about saving content to Google Drive.

Available formats
×