Hostname: page-component-848d4c4894-v5vhk Total loading time: 0 Render date: 2024-07-07T12:54:42.114Z Has data issue: false hasContentIssue false

Thermal neutron detection enhancement by 10B implantation in silicon carbide sensor

Published online by Cambridge University Press:  14 July 2014

Vanessa Vervisch
Affiliation:
IM2NP (UMR CNRS 7334) – Aix-Marseille University, Case 231 -13397 Marseille Cedex 20, France
Fatima Issa
Affiliation:
IM2NP (UMR CNRS 7334) – Aix-Marseille University, Case 231 -13397 Marseille Cedex 20, France
Stéphane Biondo
Affiliation:
IM2NP (UMR CNRS 7334) – Aix-Marseille University, Case 231 -13397 Marseille Cedex 20, France
Laurent Ottaviani
Affiliation:
IM2NP (UMR CNRS 7334) – Aix-Marseille University, Case 231 -13397 Marseille Cedex 20, France
Wilfried Vervisch
Affiliation:
IM2NP (UMR CNRS 7334) – Aix-Marseille University, Case 231 -13397 Marseille Cedex 20, France
Dora Szalkai
Affiliation:
KIT-Neutron Laboratory TU Dresden and Reactor Technology Helmholtz-Zentrum, Germany
Ludo Vermeeren
Affiliation:
SCK•CEN, Boeretang 200, B-2400 Mol, Belgium
Axel Klix
Affiliation:
KIT-Neutron Laboratory TU Dresden and Reactor Technology Helmholtz-Zentrum, Germany
Anders Hallen
Affiliation:
KTH, Electrum 229, 16440 Kista, Sweden
Andrej Kuznetsov
Affiliation:
University of Oslo, PO Box 1048 Blindern, NO-0316 Oslo, Norway
Mihai Lazar
Affiliation:
AMPERE (UMR 5005) – INSA de Lyon, 21 Av. Capelle, 69621 Villeurbanne, France
Abdallah Lyoussi
Affiliation:
CEA, DEN, DER, Instrumentation Sensors and Dosimetry Laboratory, Cadarache, F-13108 St-Paul-Lez-Durance, France
Get access

Abstract:

The purpose of this paper is to propose the enhancement of device detectors based on p-n junction in 4H-SiC for nuclear instrumentation. Particular emphasis is placed on the interest on using Boron isotope 10 as a Neutron Converter Layer in order to detect thermal neutrons. Here, we present the main results obtained during several irradiation tests performed in the Belgian Reactor 1 (BR1). We show the capability of our detectors by means of first results of the detector response at different reverse voltage biases and at different reactor power.

Type
Articles
Copyright
Copyright © Materials Research Society 2014 

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

Dullo, A., Ruddy, F., Seidel, J., Adams, J., Nico, J. and Gilliam, D., Nuclear Instruments and Methods in Physics Research A Vol 422 (1999) 4748 CrossRefGoogle Scholar
Dullo, A., Ruddy, F., Seidel, J., Adams, J., Nico, J. and Gilliam, D., Nuclear Instruments and Methods in Physics Research A Vol 498 (2003) 415423 CrossRefGoogle Scholar
Nava, F., Bertuccio, G., Cavallini, A., Vittone, E., Meas. Sci. Technol.19 (2008) 102001 CrossRefGoogle Scholar
Seshadri, S., Dulloo, A.R., Ruddy, F.H., Seidel, J.G., Rowland, L.B., IEEE Trans. Electron. Dev. 46 (1999) 567.CrossRefGoogle Scholar
Ruddy, F., Dulloo, A., Seidel, J., Trans. Am. Nucl. Soc. 90 (2004) 348.Google Scholar
Ruddy, F., Seidel, J., Nuclear Instruments and Methods in Physics Research B 263 (2007) 163168 CrossRefGoogle Scholar
Lyoussi, A. and al.: I _SMART a collaborative project on Innovative Sensor for Material Ageing and Radiation Testing: European Innovative Project for SiC applications in harsh media. KIC_ Innoenergy, CCAV, I_SMART Proposal/Exhibit 1, January 2012 Google Scholar
Issa, F., Vervisch, V., Ottaviani, L., Szalkai, D., Vermeeren, L., Lyoussi, A., Kuznetsov, A., Lazar, M., Klix, A., Palais, O., Hallen, A., IEEE Transactions on Nuclear Science, No. TNS-00518–2013.R1, in press Google Scholar
Laariedh, F., Lazar, M., Cremillieu, P., Penuelas, J., Leclerq, J-L. and Planson, D, Semicond. Sci. Technol. 28 (2013) 045007 CrossRefGoogle Scholar