Misting-free diamond surface created by sheet electron beam irradiation

Published online by Cambridge University Press:  31 January 2011

Kazuya Oguri
Affiliation:
Department of Physics, Tokai University, 1117, Kitakaname, Hiratsuka, Kanagawa, 259–1292, Japan
Nobuhiro Iwataka
Affiliation:
Department of Materials Science, Tokai University, 1117, Kitakaname, Hiratsuka, Kanagawa, 259–1292, Japan
Akira Tonegawa
Affiliation:
Department of Physics, Tokai University, 1117, Kitakaname, Hiratsuka, Kanagawa, 259–1292, Japan
Yoichi Hirose
Affiliation:
Department of Electronics, Tokai University, 1117, Kitakaname, Hiratsuka, Kanagawa, 259–1292, Japan
Kazuo Takayama
Affiliation:
Honorary Professor of Tokai University, 1117, Kitakaname, Hiratsuka, Kanagawa, 259–1292, Japan
Yoshitake Nishi
Affiliation:
Department of Materials Science, Tokai University, 1117, Kitakaname, Hiratsuka, Kanagawa, 259–1292, Japan
Get access

Abstract

We developed a diamond surface that does not mist near the room temperature under a saturated humidity atmosphere, by sheet electron beam irradiation (SEBI) treatment. SEBI treatment decreased the time to clear vision of the diamond surface. Following SEBI treatment for 1.91 s (= 0.72 MGy) to a diamond surface, the time to clear vision was less than 2 s. The effective duration time was a few hours. Based on the results of the size distribution of the drops on the misting-free diamond surface following blowing for 3 s, we proposed an explanation for the short time to clear vision of the diamond surface treated by SEBI.

Type
Articles
Copyright
Copyright © Materials Research Society 2001

Access options

Get access to the full version of this content by using one of the access options below. (Log in options will check for institutional or personal access. Content may require purchase if you do not have access.)

References

REFERENCES

1.Inoue, N., Kikuchi, M., Manabe, T., Shima, T., and Nishi, Y., Nucl. Instrum. Methods B59/60, 1328 (1991).Google Scholar
2.Inoue, N., Kikuchi, M., Shima, T., Iwase, M., and Nishi, Y., Phys. Lett. A 157, 299 (1991).CrossRefGoogle Scholar
3.Takahashi, M., Fujita, K., Ohmori, Y., Honda, N., Nishi, Y., and Tonegawa, A., Japanese Patent No. HAE8–321688 (1996).CrossRefGoogle Scholar
4.Hirose, Y. and Terasawa, Y., Japan J. Appl. Phys. 25, L519 (1986).CrossRefGoogle Scholar
5.Ojima, T., Iwataka, N., Aoki, K., Tonegawa, A., Hirose, Y., and Nishi, Y., J. Adv. Sci. 8, 103 (1996).CrossRefGoogle Scholar
6.Nishi, Y., Takagi, S., Yasuda, K., and Itoh, K., J. Appl. Phys. 70, 367 (1991).CrossRefGoogle Scholar
7.Butter, R.S., Waterman, D.R., Lettington, A.H., Ramos, R.T., and Fordham, E.J., Thin Solid Films 311, 107 (1997).CrossRefGoogle Scholar
8.Ando, T., Ishii, N., Kamoshige, M., and Sato, Y., New Diamond 10, 2 (1994).Google Scholar
9.Sappok, R. and Boehm, H.P., Carbon 6, 573 (1968).CrossRefGoogle Scholar
10.Langmuir, I., Phys. Rev. 12, 368 (1912).CrossRefGoogle Scholar
11.Turnbll, D. and Fisher, J.C., J. Chem. Phys. 17, 71 (1949).CrossRefGoogle Scholar
12.Zinke-Allmang, M., Thin Solid Films 346, 1 (1999).CrossRefGoogle Scholar
13.Young, T., Trans. R. Soc., London 95, 84 (1805).Google Scholar
14.Dupre, A., Thorie Mchanique debla Chaleur (Paris, 1869).Google Scholar