No CrossRef data available.
Article contents
Crystallinity and Unit Cell Variations in Linear High-Density Polyethylene
Published online by Cambridge University Press: 06 March 2019
Abstract
The degree of crystallinity and unit cell parameters have been determined using WAXS on a number of compression molded high-density polyethylene (HDPE) plaques processed at widely varying conditions of crystallization and annealing times and temperatures. Changes in unit cell parameters with variations in processing conditions can be explained in terms of increases in lamellar thickness of polyethylene crystals with increasing thermal treatments. Concomitant increases in the degree of crystallinity of these samples can also be explained in terms of lamellar thickening and other changes in polyethylene morphology. Crystallinity determinations using XRD data are also compared with values determined by differential scanning calorimetry (DSC) and solid-state 13C nuclear magnetic resonance (NMR). Comparisons of crystallinity values obtained by these three different techniques can reveal details of the morphology of HDPE including the presence of an interfacial zone in addition to the crystalline and amorphous components of the system.
- Type
- VI. Polymer Applications of X-Ray Scattering
- Information
- Advances in X-Ray Analysis , Volume 38: Forty-third Annual Conference on Applications of X-ray Analysis , 1994 , pp. 495 - 502
- Copyright