We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
A variety of devices are available for transcatheter closure of unwanted shunts. We describe our experience with the use of the Amplatzer vascular plug IV in a consecutive series of infants.
Methods
A total of eight consecutive infants – all born preterm at gestational ages ranging from 24 to 35 weeks – undergoing transcatheter closure of unwanted shunts – persistently patent arterial duct in five patients, an aorta to right atrium fistula in one, multiple aortopulmonary collateral vessels in one, and an azygos vein to left atrium connection in one – are described. Their age, from birth, ranged between 3 and 11 months, and weight between 2.6 and 11.3 kilograms. All devices were delivered using percutaneous arterial or venous vascular access via a large lumen (0.038 inch) 4-French delivery catheter.
Results
All lesions could be successfully occluded using one or more devices. Device diameters ranged between 4 and 8 millimetres, and exceeded the minimum diameter of the target vessel by 1 to 2 millimetres. Successful occlusion was confirmed either directly at angiography or on follow-up echocardiography. Of the infants who were mechanically ventilated prior to the procedure, three could be successfully weaned following closure of the shunt. There were no procedure-related complications.
Conclusions
The new vascular plug IV is cheap and efficacious in closing a variety of shunts in young infants, and warrants further extended clinical application.