We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
The purpose of this study was to investigate variations in surface dose, with and without the use of a Klarity® Mask (Orfit Industries America, Wijnegem, Belgium), using intensity-modulated radiotherapy (IMRT) and 3-D conventional radiotherapy (3D-CRT).
Materials and methods
Thermoluminescent dosimeters (TLDs) together with a phantom were used to examine acute skin toxicity during nasopharyngeal cancer treatment. These plans were sequentially delivered to the perspex phantom. Dosimeters were placed in five fixed regions over the skin. A Klarity mask for immobilization was used for covering the head, neck, and shoulder. The phantom was irradiated with and without a Klarity Mask, using IMRT and 3D-CRT, respectively.
Results
The Klarity mask increased the skin doses for IMRT and 3D-CRT approximately 18·6% and 8·6%, respectively, from the prescribed maximum skin dose using treatment planning system (TPS). Additionally, the average percentage dose between IMRT and 3D-CRT received on the surface region was 30·9%, 24·9% with and without Klarity mask respectively. The average percentage dose received on surfaces from the total therapeutic dose 70 Gy, without using the mask was 7·7% and 5·7%, for IMRT and 3D-CRT, respectively. The TPS overestimated the skin dose for IMRT planning by 20%, and for 3D-CRT by 16·6%, compared with TLD measurements.
Conclusions
The results of this study revealed that IMRT significantly increases acute skin toxicity, compared with CRT. Although it is recommended to use Klarity mask as a sparing tool of normal tissue, it increases the risk of skin toxicity. In conclusion, skin dose is an important issue of focus during radiotherapy.