We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
During the radiation therapy of tumoral breast, the contralateral breast (CB) will receive scattered doses. In the present study, the photon and thermal neutron dose values received by CB surface during breast cancer radiation therapy were measured.
Materials and methods:
The right breast region of RANDO phantom was considered as CB, and the measurements of photon and thermal neutron dose values were carried out on this region surface. The phantom was irradiated with 18 MV photon beams, and the dose values were measured with thermoluminescent dosimeter (TLD-600 and TLD-700) chips for 11 × 13, 11 × 17 and 11 × 21 cm2 field sizes in the presence of physical and dynamic wedges.
Results:
The total dose values (photon + thermal neutron) received by the CB surface in the presence of physical wedge were 12·06%, 15·75% and 33·40% of the prescribed dose, respectively, for 11 × 13, 11 × 17 and 11 × 21 cm2 field sizes. The corresponding dose values for dynamic wedge were 9·18%, 12·92% and 29·26% of the prescribed dose, respectively. Moreover, the results showed that treatment field size and wedge type affect the received photon and thermal neutron doses at CB surface.
Conclusion:
According to our results, the total dose values received at CB surface during breast cancer radiotherapy with high-energy photon beams are remarkable. In addition, the dose values received at CB surface when using a physical wedge were greater than when using a dynamic wedge, especially for medial tangential fields.