We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
To explore the impact of breast size on mean lung dose (MLD) for patients receiving breast radiotherapy.
Methodology
Chest wall separation (CWS), volume of tissue receiving 95% isodose and MLD were measured on 80 radiotherapy treatment plans of patients receiving tangential radiotherapy treatment to the whole breast. Breast size was categorised as small (CWS<25 cm and planned target volume (PTV)<1,500 cm3) and large (CWS>25 cm and PTV>1500 cm3). Pearson’s correlation and independent sample t-test were used to analyse data.
Results
MLD was not affected by CWS (r=−0·13, p=0·24) nor volume of tissue receiving 95% isodose (r=−0·08, p=0·49). Significant variation between small and large breasts was noted for CWS (t=8·24, p=0·00) and volume of tissue receiving 95% isodose (t=5·68, p=0·00). No significant variation was noted between small and large breast for MLD (t=−0·26, p=0·80) and between left and right breasts for CWS (t=1·42, p=0·16) and volume of tissue receiving 95% isodose (t=−1·08, p=0·28). Significant difference between left (18–808 cGy) and right breast (325–365 cGy) was demonstrated for MLD (t=3·03, p=0·00).
Conclusion
This study demonstrated lack of correlation between breast size and MLD. Further research is recommended for justification of alternative techniques for this subgroup of patients to provide optimised radiotherapy delivery.