We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
This study was conducted for comparison of techniques between volumetric modulated arc therapy (VMAT), forward-planning intensity-modulated radiotherapy (FIMRT) and conventional technique for left-sided breast radiotherapy after conservative surgery.
Methods
In all, 20 postoperative left breast carcinoma patients were included in this study. In all plans the planning target volume (PTV) was the breast tissue with appropriate margin as per our institutional protocol. The contouring was done on a Monaco Sim (V5.00.02) contouring workstation. All patient were planned using partial arc VMAT in Monaco treatment planning system (TPS) (V5.00.02) and treated on Elekta Synergy linear accelerator. The 3D conformal radiotherapy (3DCRT) and FIMRT planning were done in CMS XIO (V5.00.01.1) TPS. The 3DCRT planning consisted of conventional medial and tangential wedge portals with multileaf collimator field shaping conforming to the target volume. For all the plans generated the following metrics were scored: V105%, V100%, V95%, mean dose (for PTV), V5%, V20%, D2cc and mean dose (for organs at risk).
Results
The mean PTV volume for 20 patients was 1,074·6±405·1 cc. The highest PTV dose coverage was observed in the 3DCRT technique with 94·1±1·8% of the breast PTV receiving 95% of the prescription dose (V95%). However, it was also observed that this technique resulted in 21·3±10% of the PTV receiving more than 105% of the prescription dose (V105%), which was highest among the three techniques. In contrast, VMAT yielded lowest V95% of 93·0±1·8 and 3·3±5·5% of V105%.
Conclusion
This study concluded equivalent result between FIMRT and VMAT. However, VMAT was found to be the choice of radiotherapy technique as it produces lesser dose distribution to heart compared with any other technique.
Recommend this
Email your librarian or administrator to recommend adding this to your organisation's collection.