We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
The purpose of the study was to evaluate the impact of changes in breathing pattern inside the breath-hold window (BHW) during deep inspiration breath hold treatment for carcinoma left breast patients post-conservative surgery.
Methods:
Ten patients of carcinoma left breast post-conservative surgery were prospectively selected. Three sets of CT plain images were acquired, one with 5 mm deep inspiration BHW (DIBHR) and the other one with 1 mm BHW matching the lower threshold (DIBHL) and the third one with 1 mm BHW matching the upper threshold (DIBHH) as DIBHR. For all patients, forward intensity-modulated radiotherapy (FIMRT) and volumetric modulated arc therapy (VMAT) plans were generated in the 5 mm BHW CT series and the same plan being copy and pasted in other series. Target volume doses and critical structure doses were tabulated.
Results:
Planning target volume coverage was adequate and no significant differences were found in any CT series. Significant differences noted in average left lung V5%, V10% and V18% doses between DIBHR versus DIBHH (p values = 0·0461, 0·0283 and 0·0213, respectively) and DIBHL versus DIBHH (p values = 0·0434, 0·0484 and 0·0334, respectively) for FIMRT plans and V18% doses in DIBHR versus DIBHH (p = 0·0067) in VMAT. No differences in heart and apex of heart doses were found. Left anterior descending artery (LAD) mean doses were significant in DIBHL versus DIBHR, DIBHR versus DIBHH and DIBHL versus DIBHH (p = 0·0012, 0·0444 and 0·0048, respectively) series for FIMRT plans and DIBHR versus DIBHH and DIBHL versus DIBHH (p = 0·0341, 0·0001) for VMAT plans.
Finding:
The changes in the breathing pattern inside DIBH window level cause some variation in LAD doses and no other significant differences in any parameters noted, so care should be taken while treating patients with preexisting cardiac conditions.
The aim of this study is to evaluate the influence of flattened and flattening filter-free (FFF) beam 6 MV photon beam for liver stereotactic body radiation therapy by using volumetric modulated arc therapy (VMAT) technique in deep inspiration breath hold (DIBH) and free breathing condition.
Materials and methods
Eight liver metastasis patients (one to three metastasis lesions) were simulated in breath hold and free breathing condition. VMAT-based treatment plans were created for a prescription dose of 50 Gy in 10 fractions, using a 230° coplaner arc and 60° non-coplanar arc for both DIBH and free breathing study set. Treatment plans were evaluated for planning target volume (PTV) dose coverage, conformity and hot spots. Parallel and serial organs at risk were compared for average and maximum dose, respectively. Dose spillages were evaluated for different isodose volumes from 5 to 80%.
Result
Mean D98% (dose received by 98% target volume) for FFF in DIBH, flattened beam in DIBH, FFF in free breathing and flatten beam in free breathing dataset were 48·9, 47·81, 48·5 and 48·3 Gy, respectively. D98% was not statistically different between FFF and flatten beam (p = 0·34 and 0·69 for DIBH and free breathing condition). PTV V105% (volume receiving 105% dose) for the same set were 3·76, 0·25, 1·2 and 0·4%, respectively. Mean heterogeneity index for all study sets and beam models varies between 1·05 and 1·07. Paddik conformity index using unflattened and flattened beam in DIBH at 98% prescription dose were 0·91 and 0·79, respectively. Maximum variation of isodose volume was observed for I-5%, which was ranging between 2288·8 and 2427·2 cm3. Increase in isodose value shows a diminishing difference in isodose volumes between different techniques. DIBH yields a significant reduction in the chest wall dose compared with free breathing condition. Average monitor units for FFF beam in DIBH, flattened beam in DIBH, FFF beam in free breathing CT dataset and flattened beam in free breathing CT dataset were 1318·6 ± 265·1, 1940·3 ± 287·6, 1343·3 ± 238·1 and 2192·5 ± 252·6 MU.
Conclusion
DIBH and FFF is a good combination to reduce the treatment time and to achieve better tumour conformity. No other dosimetric gain was observed for FFF in either DIBH or free breathing condition.
Recommend this
Email your librarian or administrator to recommend adding this to your organisation's collection.