We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
This study attempts to investigate fiducial marker (FM) migration and calculate the prostate planning target volume (PTV) margin considering the setup errors after translation corrections alone (T) and translation plus rotational corrections (T+R) and anatomy variation with respect to the corrected fiducial position, analysed on cone beam computed tomography (CBCT) images.
Methods and materials:
CBCT images from 25 patients are analysed for FM movements, setup error and anatomy variation with respect to the seed match positions. Systematic and random components of setup error and prostate movements are used to calculate the PTV margin for CBCT-based FM localisation in two scenarios, translation corrections only and translation plus rotational correction. MTNW887825 soft tissue gold markers (Civco, Orange City, FL, USA) were used with the department-specific immobilisation system and rectal and bladder filling protocols.
Results:
The average directional inter-marker distance variation is −0·05 ± 0·90 mm. The systematic setup errors for T+R are 0·40, 0·63 and 0·80 mm in right–left (RL), anterior–posterior (AP) and superior–inferior (SI), respectively. The corresponding values for T only are 0·54, 0·69 and 0·90 mm. The systematic prostate movement from T+R corrected FM positions are 0·65, 1·27 and 1·32 mm in the RL, AP and SI directions.
Findings:
Minimal FM movements are noted from the study. The PTV margins to incorporate the daily T+R corrected setup error and prostate deformation are found to be 2·5, 4·5 and 5·2 mm in the RL, AP and SI directions, respectively. The corresponding margins for T only corrected scenario are found to be 2·8, 4·8 and 5·7 mm.
This is a prospective study to evaluate the dosimetric benefits of treatment plan adaptation for patients who had undergone repeat computed tomography (ReCT)and re-planning due to treatment-induced anatomical changes during radiotherapy.
Materials and Methods
This study involved five head and neck cancer patients who had their treatment plan modified, based on weekly thrice imaging protocol. Impact of mid-course imaging was assessed in patients using ReCT and cone beam computed tomography (CBCT)-based dose verification. Patients were imaged, apart from their initial CT, during the course of their radiation therapy with a ReCT and on board imager CBCT (Varian Medical Systems Inc., Palo Alto, CA, USA). Each CBCT/CT series was rigidly registered to the initial CT in the treatment planning system Eclipse (Varian Medical Systems Inc.) using bony landmarks. The structures were copied to the current CBCT/CT series and, where needed, manually edited slicewise. The dose distribution from the treatment plan was viewed as of the current anatomy by applying the treatment plan the CBCT/CT series, and studying the corresponding dose–volume histograms for organs at risk doses.
Results
The reduction of parotid volumes due to weight loss was observed in all patients, which means an increase in predicted mean doses of parotid when initial CT plan was re-calculated on ReCT and CBCT (Table 1). This explains the necessity of adaptive planning. The predicted mean dose of parotid glands was increased and constraints to spinal cord and skin were exceeded, so re-planning was performed.
Conclusions
The CBCT is a useful tool to view anatomic changes in patients and get an estimate of their impact on dose distribution. Re-planning based on imaging in head and neck patients during the course of radiotherapy is mandatory to reduce side effects.
This study evaluated the impact of a daily and weekly image-guided radiotherapy protocols in reducing setup errors and setting of appropriate margins in head and neck cancer patients.
Materials and methods
Interfraction and systematic shifts for the hypothetical day 1–3 plus weekly imaging were extrapolated from daily imaging data from 31 patients (964 cone beam computed tomography (CBCT) scans). In addition, residual setup errors were calculated by taking the average shifts in each direction for each patient based on the first three shifts and were presumed to represent systematic setup error. The clinical target volume (CTV) to planning target volume (PTV) margins were calculated using van Herk formula and analysed for each protocol.
Results
The mean interfraction shifts for daily imaging were 0·8, 0·3 and 0·5 mm in the S-I (superior-inferior), L-R (left-right) and A-P (anterior-posterior) direction, respectively. On the other hand the mean shifts for day 1–3 plus weekly imaging were 0·9, 1·8 and 0·5 mm in the S-I, L-R and A-P direction, respectively. The mean day 1–3 residual shifts were 1·5, 2·1 and 0·7 mm in the S-I, L-R and A-P direction, respectively. No significant difference was found in the mean setup error for the daily and hypothetical day 1–3 plus weekly protocol. However, the calculated CTV to PTV margins for the daily interfraction imaging data were 1·6, 3·8 and 1·4 mm in the S-I, L-R and A-P directions, respectively. Hypothetical day 1–3 plus weekly resulted in CTV–PTV margins of 5, 4·2 and 5 mm in the S-I, L-R and A-P direction.
Conclusions
The results of this study show that a daily CBCT protocol reduces setup errors and allows setup margin reduction in head and neck radiotherapy compared to a weekly imaging protocol.