We use cookies to distinguish you from other users and to provide you with a better experience on our websites. Close this message to accept cookies or find out how to manage your cookie settings.
To save content items to your account,
please confirm that you agree to abide by our usage policies.
If this is the first time you use this feature, you will be asked to authorise Cambridge Core to connect with your account.
Find out more about saving content to .
To save content items to your Kindle, first ensure [email protected]
is added to your Approved Personal Document E-mail List under your Personal Document Settings
on the Manage Your Content and Devices page of your Amazon account. Then enter the ‘name’ part
of your Kindle email address below.
Find out more about saving to your Kindle.
Note you can select to save to either the @free.kindle.com or @kindle.com variations.
‘@free.kindle.com’ emails are free but can only be saved to your device when it is connected to wi-fi.
‘@kindle.com’ emails can be delivered even when you are not connected to wi-fi, but note that service fees apply.
Deep inspiration breath hold (DIBH) is a method of motion management used in stereotactic ablative body radiotherapy (SABR) for lung tumours. An external gating block marker can be used as a tumour motion surrogate, however, inter-fraction gross target volume (GTV) displacement within DIBH occurs. This study measured this displacement during a reproducible breath hold regime. In addition, factors such as position of the gating block marker were analysed.
Methods and materials
A total of 121 cone beam computed tomography scans (CBCTs) from 22 patients who received DIBH SABR were retrospectively evaluated and the magnitude of inter-fraction GTV displacement was calculated for each fraction. This data was analysed to assess if any correlation existed between tumour displacement and variation in the gating block marker position on the patient, the amplitude of breath hold (BH) at computed tomography (CT), the amplitude of BH at treatment and the tumour location.
The measured tumour displacement was applied to the original planning CT to evaluate the dosimetric effect on surrounding organs at risk (OARs) using cumulative dose volume histograms (DVHs).
Results
BH amplitude was reproducible within 0·13±0·1 cm (mean±standard deviation). The magnitude of tumour displacement within BH ranged from 0 to 1·52 cm (0·41±0·28 cm). Displacement in the superior-inferior, anterior-posterior and left-right planes were 0·31±0·26 cm, 0·16±0·18 cm and 0·07±0·12 cm, respectively. No statistically significant correlation was detected between tumour displacement within DIBH and the factors investigated. The range of variation in OAR dose was −7·0 to +3·6 Gy with one statistically significant increase in OAR dose observed (oesophagus mean dose increasing by 0·16 Gy).
Findings
Reproducible BH was achievable across a range of patients. Inter-fraction GTV displacement measured 0·41±0·28 cm. Due to this low level of motion, the correction of soft tissue moves did not adversely affect OAR dose.